INSTRUCTIONS FOR CORRECT ASSEMBLY : 

 
a)  Locate the housing on a reinforced concrete slab to prevent the compact housing from 

getting lifted or broken due to water pressure or other elements. The ground around the unit 
should be well compacted. For this, the installer will have to check the ground conditions 
and take the necessary steps to prepare it to locate the compact housing (this will avoid 
excessive pressure exerted on the housing walls). 

 
b)  The embedded housing should protrude at least 5 cm above ground level to avoid flooding 

risks  from the top (heavy rains). 

 
c)  In winter, prevent the unit from suffering frost . ADVICE: Dismount the pump and store it 

together with other electric elements in a dry place. Drain water from all pipework. 

 
d)  The pipework should be installed at least till the compact connection height and correct 

diameter. If it is not possible, install check valves. 

 
e)  Provide a correct pressure drainage for filter backwashing. Also assure that the correct 

power cable is provided. 

 
f)  The embedded housing should be located at a minimum distance of 3 m from the pool. This 

minimum distance is to assure a security area around the pool limits as established by 
Safety Rules and not because of water flow or pressure requirements. 

 
 

g) 

Noise: Will depend on the pump quality. Insert vibration pads below pump.

 

 

  
ASTRAL does not hold itself responsible for the installation of this compact housing. We reserve 
the right to make modifications. 

 
 