16
Suspected malfunctions are often due to causes that the users can
fix themselves, therefore check the product using this section.
Problem
Possible Cause
Solution
1. Product
does not start
1.1 No power supply
1.2 Product damaged.
1.3 Short circuit in
motor winding.
1.4 Wear out of carbon
brush.
1.1 Check the plug
1.2 Check it by a
technician
1.3 Replace stator or
rotor by technician.
1.4 Replace carbon
brush by technician.
2.
Planer starts,
but cutter-
head does not
move or wood
remains uncut.
2.1 Worn or broken
belt.
2.2 Blade not
extended beyond
foot.
2.1 Replace belt.
2.2 Adjust for more
cutting depth.
3.Unsatisfactory
result
(Poor
cutting quality)
3.1
Improper
installation of
cutting blade.
3.2 Damaged/Worn
out cutting blade.
3.1
Reinstall cutting
blade.
3.2 Replace or Sharpen
cutting blade.
4.
Excessive
noise during
running.
4.1 Motor bearing
damage.
4.1 Replace bearing by
a technician.
5. Machine
overheating
5.1 Overload running.
5.2 Motor bearing
damage.
5.1 Conduct the
operation correctly.
5.2 Check or replace it
by technician.