background image

SFC-199 - Fuel Conversion to Propane (NG to LP) Kit P-844

|

3

Fuel Conversion Instructions

You must be a qualified technician to perform a fuel conversion. 

Model Number

Orifice Size

SFC-199

535

Table 2 

 - Propane Orifice Chart

To perform a fuel conversion:

 1.  Turn off the gas supply at the gas shut-off valve.

 2.  Disconnect the electrical power.

 3.  Disconnect the nut at the gas valve outlet (top of the gas valve), and remove the O-ring and orifice.

 4.  Insert the correct orifice into the O-ring, and re-install into the nut at the gas valve outlet (top of the gas valve), 

and then tighten the nut.

 5.  Restore the gas supply by opening the gas control valve.

 6.  Test for leaks by using an approved leak detection solution on all joints.

 7.  Power on the  appliance.

Now, carefully follow the procedures on Combustion Testing and Adjustment.

Reviews: