![IBC EX Series Installation & Operating Manual Download Page 108](http://html1.mh-extra.com/html/ibc/ex-series/ex-series_installation-and-operating-manual_3222196108.webp)
8.2 Electronic components
This section details the method for troubleshooting the non-standard electronic components on the
boiler.
8.2.1 Temperature sensors
The resistance of the temperature sensors varies inversely with temperature. To test, measure the
temperature of the sensed environment and compare with the value derived from the measurement
of the resistance (obtained by connecting a good quality test meter capable of measuring up to
5,000 kΩ (5,000,000Ω) at the controller end of the sensor lead).
To obtain a resistance reading, remove power to the boiler. For the supply water, return water, and
vent temperature sensors, remove the wire leads by disconnecting their respective Molex
connectors. Place multi-meter probes into the sensor’s female Molex connector socket. Do not
apply voltage to the sensor as damage may result.
The supply water and vent temperature sensors each contain two separate circuits. Test each pair.
Both circuits must deliver accurate (although not necessarily identical) readings. Note that failures
may occur only within certain temperature ranges.
Temp. °F/°C
Resist.
Ω – Ohm
Temp. °F/°C
Resist.
Ω – Ohm
0 / -18
85,362
100 / 38
5,828
5 / -15
72,918
105 / 41
5,210
10 / -12
62,465
110 / 43
4,665
15 / -9
53,658
115 / 46
4,184
20 / -7
42,218
120 / 49
3,760
25 / -4
39,913
125 / 52
3,383
30 / -1
34,558
130 / 54
3,050
35 / 2
29,996
135 / 57
2,754
40 / 4
26,099
140 / 60
2,490
45 / 7
22,763
145 / 63
2,255
50 / 10
19,900
150 / 66
2,045
55 / 13
17,436
155 / 68
1,857
60 / 16
15,311
160 / 71
1,689
65 / 18
13,474
165 / 74
1,538
70 / 21
11,883
170 / 77
1,403
106
Section: Troubleshooting
Summary of Contents for EX Series
Page 62: ...Intentionally left empty...
Page 80: ...Intentionally left empty...
Page 121: ...Appendices Wiring diagrams Figure 73 Controller electrical diagram 119 Appendices...
Page 122: ...Figure 74 Internal wiring diagram EX 400 and EX 500 models 120 Section Appendices...
Page 123: ...Figure 75 Internal wiring diagram EX 700 and EX 850 models 121 Wiring diagrams...
Page 124: ...Figure 76 Sequence of Operation 122 Section Appendices...
Page 126: ...Intentionally left empty...
Page 128: ...126 Boiler parts diagram EX 400 and EX 500...