SAST0715

Page 

2

 

 

1. 

Water to be tested should be taken from a tap after the water softener

 

2. 

Measure 10ml of water into plastic bottle supplied (approximately 1/3 full)

 

3. 

Add  one  Yes/No  tablet  to  sample  water,  replace  cap  and  shake  until  tablet
has completely dissolved.

 

 (NOTE: do not handle Yes/No tablet with fingers)

 

4. 

The  final  colour  to  be  obtained  for  soft  water  is  green.  (Note:  The  shade  of
green may vary.) If the colour turns red, the water is above 20 mg/l hardness,
therefore another regeneration is recommended.

 

5. 

Rinse plastic bottle after each test has been completed.

 

6. 

When  used  as  above,  the  tablets  change  the  colour  from  green  to  red  at  a
hardness of approximately 20ppm based on a sample volume of 10mls.

          

Other hardness test kits are available for more accurate testing eg.

Hardness Tablets

Directions:

Take  a  50ml  sample  of  water  in  a  screw  capped  bottle.  Add  one  (1)
tablet to sample, shake or crush to disintegrate. Repeat until last trace
of  reddish  tinge  disappears.  The  final  colour  is  usually  blue  but  with
some water a greyish coloured end point is obtained.

Using 50ml sample -
Hardness ppm = (number of tablets x 40) - 20

LR (BW) Tablets

Directions:

Take  a  100ml  sample  of  water  in  a  screw  capped  bottle.  Add  one  (1)
tablet to sample, shake or crush to disintegrate. Repeat until last trace
of  reddish  tinge  disappears.  The  final  colour  is  usually  blue  but  with
some water a greyish coloured end point is obtained.

Using 100ml sample -
Hardness ppm = (number tablets x 2) – 1

Contact IBC Water if further details are required.

HARDNESS TEST

Summary of Contents for SAST0715

Page 1: ... OPERATING INSTRUCTIONS Model SAST0715 Serial No Telephone 07 3219 2233 Facsimile 07 3219 2266 Email sales ibcwater com au Website www ibcwater com au FILTRATION WATER TREATMENT PRODUCTS for commercial industrial and residential application Manufacturer and Supplier of ...

Page 2: ...ximately 20ppm based on a sample volume of 10mls Other hardness test kits are available for more accurate testing eg Hardness Tablets Directions Take a 50ml sample of water in a screw capped bottle Add one 1 tablet to sample shake or crush to disintegrate Repeat until last trace of reddish tinge disappears The final colour is usually blue but with some water a greyish coloured end point is obtaine...

Page 3: ...ams call ð C 3 ð Daily Water Usage in litres call ð D For household situations allow 250 litres per person per day CALCULATION N 1000 x C D x H Select nearest lower whole number If necessary consult your dealer or IBC Water Treatment for advice on setting up the softener EXAMPLE Household use for 2 people on 220 mg l hard water using Model SAST0715 at 1050 grams capacity N 1000 x 1050 500 x 220 9 ...

Page 4: ...he unit must be installed in accordance with local codes 7 Do not over tighten connections 8 Drain line ID must be at least 12mm 9 Teflon tape should be used when installing he drain fitting into the control valve 10 The drain line must be free of kinks 11 A safety float with an air check is installed 12 Insure all connections are tight 13 To initiate regeneration turn the twist the timer knob clo...

Page 5: ...NS 1 Floor Level a Use any length of 1 2 pipe or larger 2 Control Level a For 30 or less of drain line use 1 2 pipe or larger b For 30 or more of drain line use 3 4 pipe or larger Never connect the drain line into a drain sewer line or drain tray without an air gap Air gap should be located in drain line above liquid level in brine tank BRINE TANK DRAIN It is recommended that the brine tank have a...

Page 6: ...d ensure the bypass valve is closed Run the nearest cold water tap for a least 15 minutes to ensure the resin bed is flushed BRINE TANK 1 Place at least 25kg of a coarse refined grade of salt Water Softener Salt in the brine tank and always maintain dry salt above the water level The tank can hold up to 50kg of coarse salt 2 Periodically it will be necessary to allow the salt to run out and clean ...

Page 7: ...SAST0715 Page 7 During regeneration raw hard water is bypassed to service so it is advisable to regenerate the unit when water is not needed ...

Page 8: ...SAST0715 Page 8 Water Conditioning Control System Installation Operating and Maintenance Manual 541 030 VALVE ...

Page 9: ...r tube and up through the resin bed to drain This slow flow of water pushes the brine solution through the resin bed In brine draw concentrated salt brine is drawn from the brine tank and directed to flow down through the riser tube and up through the resin bed to the drain Brine is drawn until the air check in the brine tank closes NOTE THIS CONTROL VALVE FUNCTIONS WITH A PRESSURISED BRINE LINE T...

Page 10: ...r w o rings 1 16 529 244 Gasket Cross Over Port 1 17 541 244 Body Stem Assembly 1 18 185 024 1 O ring Small Seat Insert 1 19 541 204 Seal Insert 1 20 185 028 12 O ring Large Seat Insert 1 21 541 256 Main Diaphragm 1 22 19 3 C Clip Main Diaphragm 1 23 516 221 Return Spring Main Diaphragm 1 24 541 291 11 1 Hr Timer Assembly 1 25 15 87 Screw Timer Mount 4 26 19 90 Screw Adapter Ring 2 27A 185 231 1 O...

Page 11: ...SAST0715 Page 11 ...

Page 12: ...y set b Verify water usage matches system size and salt dosage c Replace safety float 4 Loss of resin a Faulty air check in storage tank b Leak at the distributor tube a Clean or replace air check b Verify that the distributor tube is seated correctly and is not cracked 5 Salt water to service a Brine slow rinse cycle time set too short b Excessive water in the storage tank c Brine injector unders...

Page 13: ...nd that the outside edges of the main diaphragm are tucked into the valve body Rinse Adjustment Valve Replacement 1 Place the bypass valve into bypass position 2 Relieve the system pressure Remove the four 4 head mounting screws 3 Lift the timer assembly away from the valve body 4 Remove the c clip from the centre of the diaphragm 5 Lift the diaphragm away from the body stem assembly 6 Remove the ...

Page 14: ...ace a hand under the backcap and remove the backcap The check disc return spring will fall into your hand 5 Remove the check disc from the back of the body stem assembly 6 Inspect the rubber seal on the check disc for wear Clean or replace if necessary 7 Re install the check disc on body stem assembly 8 Place a small amount of Dow 111 silicone based lubricant on the back cap centre post 9 Insure t...

Page 15: ...sor Cabinet Model Float Distance X SAS0715 100mm SAS0922 200mm SAS1029 260mm Adjustment of Softener Brine Valve 1 Lift float rod to full up position 2 Set float to distance shown Measure from the top of the crown nut to the bottom of the float ...

Reviews: