AS0922TC-CL
Page
11
Inlet/Outlet Fittings
25mm BSPF PVC elbows
Cycles
6
Valve Material
Noryl (1) or equivalent
Regeneration
Down flow
FLOW RATES
Service @15psi/1 bar drop (includes bypass & meter)
102 lpm
Backwash @25psi/1.7 bar drop (includes bypass)
102 lpm
OPERATING PRESSURE
Minimum/Maximum
330-600 kpa (48-100 psi)
OPERATING TEMPERATURE
5°C---43°C
DIMENSIONS & WEIGHT
Distributor Pilot
1.050” OD Pipe (3/4” NPS)
Drain Line
½” (12mm) Hose Tail
Brine Line
3/8” OD Poly Tube
Mounting Base
2 /12” – 8 NPSM
Height from Top of Tank
7 3/8” (187mm)
Weight
4.5lbs (2kg)
Distributor Pilot
12mm Above Tank Top
ELECTRICAL SPECIFICATIONS
AC Adaptor
Supply Voltage
230V AC
Supply Frequency
50 Hz
Output Voltage
12—16 V AC
Output Current
500 mA
CYCLES OF OPERATION
Factory Set
Minutes
Backwash 1
st
(upflow)
C1
8
Regenerate draw/slow rinse (downflow)
C2
70
Backwash 2
nd
(upflow)
C3
10
Fast Rinse (downflow)
C4
6
*Regenerant Refill (in service with treated water)
C5
9
Service (down flow)
C0
Note C1 to C4 are fixed values and cannot be varied.
C5 will vary to suit model of softener
(Noryl is a trademark of General Electric)
GENERAL” WS1 TC” CONTROL VALVE
SPECIFICATONS
Summary of Contents for AS0922TC-CL
Page 3: ...AS0922TC CL Page 3...
Page 10: ...AS0922TC CL Page 10 MODEL AS0922 WATER SOFTENER WITH CONTROL VALVE SERIES MODEL WS1 TC...
Page 23: ...AS0922TC CL Page 23 SPARE PARTS AND SERVICING INSTRUCTIONS...
Page 32: ...AS0922TC CL Page 32 flow diagram backwash Flow Diagram Down flow Brine...
Page 33: ...AS0922TC CL Page 33 flow diagram downflow brine Flow Diagrams Rinse and Fill...
Page 34: ...AS0922TC CL Page 34 flow diagram rinse flow diagram fill WS1 Wrench Order No V3193 01...
Page 41: ...AS0922TC CL Page 41...