Hotter water increases the risk of scald injury.  Before changing the temperature setting, see

instruction manual.

This water heater must be installed in accordance with local codes, if any; if not follow the 

National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code,

CAN/CSA B149.1, as applicable.

Failure to correctly install and operate this appliance can result in severe personal injury

The water heater, if utilized, shall have a pressure relief valve installed within 6” [152mm] of the

DHW HOT outlet connection with the relief valve spindle installed in the vertical position. 

The water heater, if utilized, requires a pressure relief valve identified with the ASME V or HV

symbol and set to relieve at or below 150psi of domestic water pressure and a minimum

For complete information refer to installation manual.

Read and follow warnings and instructions.

or death.

Refer to the Water Heater User’s Manual before operating relief valve.

relieving capacity of 199,000 Btu/hr with 3/4” NPT threads.  For safe operation of the water

heater, the relief valve must not be removed from its designated point of installation or plugged.

Touch the panel above the White Dot twice, then touch the Tap. Adjust the water temperature 

with the Plus + and Minus – then touch the Return button to save the changes.

ADJUSTABLE TEMPERATURE SETTING

CAUTION

WATER HEATER INSTALLATION GUIDELINES

WARNING

BURN

HOT

DANGER

° 

Water temperture over 125°F (52°C) can cause severe burns instantly

  or death from scalds.

° 

Children, disabled, and elderly are at highest risk of being scalded.

° 

See instruction manual before setting temperature at water heater.

° 

Feel water before bathing or showering.

° 

Temperature limiting valves are available, see manual.

Summary of Contents for SFC Series

Page 1: ...IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a nearby phone Follow the gas suppli...

Page 2: ...e information in this manual is not followed exactly a re or explosion may result causing property damage personal injury or loss of life WARNING Points out a potentially hazardous situation which mus...

Page 3: ...Water Modes 10 Tankless Domestic Hot Water Standard Comfort and ECO Comfort Modes 10 SPACE HEATING 11 SEQUENCE OF OPERATION 11 LIGHTING SHUTTING DOWN THE UNIT 13 MAINTENANCE 14 General Care 14 Daily...

Page 4: ...person WARNING Do not use this unit if any part has been under water Immediately call a quali ed service technician to inspect the unit and to replace any part of the control system and any gas contr...

Page 5: ...50psi of domestic water pressure and a minimum For complete information refer to installation manual Read and follow warnings and instructions or death Refer to the Water Heater User s Manual before o...

Page 6: ...USER S INFORMATION MANUAL 6 SFC COMBI BOILERS PAGE INTENTIONALLY LEFT EMPTY...

Page 7: ...g Indicator G Wrench Service Reset H Return Arrow Enter Save I Numerical Display Service Display Table 1 Controller Indicators and Buttons INSTALLER INTERFACE Turning Appliance ON OFF To turn on the u...

Page 8: ...water temperature To access the main menu 1 Touch the area above the white dot twice 2 Touch the Space Heating button 3 To change the value touch the Plus or Minus buttons 4 To save the changes touch...

Page 9: ...Touch the area above the white dot 2 Touch the Tap button The tankless domestic hot water temperature target appears on the main display 3 To change the DHW temperature target touch the Plus or Minus...

Page 10: ...e of learning when the domestic hot water is used During the low use periods the heat exchanger is allowed to cool To switch between the 3 modes 1 Touch the area above the white dot 2 Touch the Tap bu...

Page 11: ...le at www ibcboiler com The unit supplies heat to the space using an outdoor reset line With an outdoor sensor installed the unit will automatically adjust its space heating water temperature based on...

Page 12: ...of time Service Display 0 7 If the burner is on to maintain the heat exchanger temperature for DHW Service Display 7 8 If the burner is on for frost protection Service Display 9 MAIN DISPLAY LIT DISPL...

Page 13: ...13 USER S INFORMATION MANUAL SFC COMBI BOILERS LIGHTING SHUTTING DOWN THE UNIT...

Page 14: ...he pH of the water coming out of the neutralizer is above 6 0pH If the pH is below 6 0 then the neutralizer will need to be re charged or replaced Contact your quali ed service technician for service...

Page 15: ...ressure will drop This uid must be replaced IBC highly recommends using a system pressurization unit such as an Axiom Industries model MF200 to re ll and pressurize your system Capture the discharged...

Page 16: ...USER S INFORMATION MANUAL 16 SFC COMBI BOILERS SERVICE RECORD DATE LICENSED CONTRACTOR DESCRIPTION OF WORK DONE...

Page 17: ...17 USER S INFORMATION MANUAL SFC COMBI BOILERS Revision History R0 DECEMBER 2018 Initial release R1 NOVEMBER 2019 Table on water quality modi ed...

Page 18: ...5M8 Tel 604 877 0277 Fax 604 877 0295 Toll Free 1 844 432 8422 www ibcboiler com 120 234 R1 84102401 NOVEMBER 2019 IBC Technologies Inc 2019 IBC Technologies USA Inc 1702 Taylors Lane Cinnaminson NJ 0...

Reviews: