1.3.4 Set hysteresis low voltage
SET_HYSTERESIS_LOW_VOLTAGE
Hysteresis Low Voltage setting .
Request
Header
Size
Command
Data0
Data1
CRC
0xFF
0xEE
0x02 SET_HYSTERSIS_LOW High Byte
Low Byte
Round off to the 1st decimal place.
Ex. Setting 11.2V mapping to 11200 (11.2x1000) = 2BC0(hex)
Data0 = 2B(hex)
Data1 = C0(hex)
The tolerance for the temperature measurement is plus and minus 0.3
Volts.
Reply
Header
Size Command
Data
CRC
0xFF 0xEE 0x0
0
SET_HYSTERSIS_LOW
None
1.3.5 Set Power On Delay Timer
SET_POWER_ON_DELAY_TIMER
Power on delay timer setting.
Request
Header Size Command
Data0
Data1
CRC
0xFF
0xEE
0x02 SET_POWER_ON_DELAY_TIMER N
(Minutes)
N
(seconds)
Reply
Header
Size
Command
Data
CRC
0xFF 0xEE 0x00 SET_POWER_ON_DELAY_TIMER
None