52
MI992
User’s Manual
4.4.6
iSmart Controller
BIOS Setting
Description
Power-On after Power
failure
Enables / Disables the system to be turned on
automatically after a power failure.
Temperature
Guardian
Generate the reset signal when system hands up
on POST.
Schedule Slots
Sets up the hour / minute / day for the power-on
schedule for the system.
Options:
•
None
•
Power On
•
Power On / Off
Important:
If you would like to set up a schedule
between adjacent days, configure two schedule
slots.
For example, if setting up a schedule from
Wednesday 5 p.m. to Thursday 2 a.m., configure
two schedule slots. But if setting up a schedule
from 3 p.m to 5 p.m. on Wednesday, configure
only a schedule slot.