background image

 

 
 
 
 
 
 

FWA8600 

1U Rackmount 

Network Appliance 

 

 

 
 

User’

s Manual 

 

Version 1.0 

(Feb. 2019)

 

 

 

Summary of Contents for FWA8600

Page 1: ...FWA8600 1U Rackmount Network Appliance User s Manual Version 1 0 Feb 2019 ...

Page 2: ...to the products described in this document without prior notice Every effort has been made to ensure the information in the document is correct however IBASE does not guarantee this document is error free IBASE assumes no liability for incidental or consequential damages arising from misapplication or inability to use the product or the information contained herein nor for any infringements of rig...

Page 3: ...cy energy and if not installed and used in accordance with manufacturer s instructions may cause harmful interference to radio communications WEEE This product must not be disposed of as normal household waste in accordance with the EU directive of for waste electrical and electronic equipment WEEE 2012 19 EU Instead it should be disposed of by returning it to a municipal recycling collection poin...

Page 4: ...is with a cloth Then wipe the chassis with a dry cloth Vacuum the dust with a computer vacuum cleaner to prevent the air vent or slots from being clogged WARNING Attention during use Do not use this product near water Do not spill water or any other liquids on your device Do not place heavy objects on the top of the device Operate this device from the type of power indicated on the marking label I...

Page 5: ...CTS HOWEVER THAT FAILS DUE TO MISUSE ACCIDENT IMPROPER INSTALLATION OR UNAUTHORIZED REPAIR SHALL BE TREATED AS OUT OF WARRANTY AND CUSTOMERS SHALL BE BILLED FOR REPAIR AND SHIPPING CHARGES Technical Support Services 1 Visit the IBASE website at www ibase com tw to find the latest information about the product 2 If you need any further assistance from your distributor or sales representative prepar...

Page 6: ...ware Configuration 10 2 1 Installation Replacement 11 2 1 1 Network Module 12 2 1 2 HDD or SSD 12 2 1 3 Memory Module 14 2 1 4 IPMI Module 15 2 1 5 Fan 16 2 1 6 Redundant Power Supply Unit 16 2 2 Pinout for Console Port 16 2 3 Setting the Jumper 17 2 4 Jumper Connector Locations on Motherboard 18 2 5 Jumper Quick Reference 19 2 5 1 AT ATX Mode JP8 19 2 5 2 Clearing CMOS Data JP3 20 2 5 3 Clearing ...

Page 7: ...uper I O Configuration 37 3 4 5 NCT7904D HW Monitor 37 3 4 6 Serial Port Console Redirection 38 3 4 7 Network Stack Configuration 41 3 4 8 CSM Configuration 42 3 4 9 NVMe Configuration 43 3 4 10 USB Configuration 44 3 4 11 Intel R Virtual RAID on CPU 45 3 4 12 All CPU Information 45 3 5 Platform Configuration 46 3 5 1 PCH Configuration 47 3 5 2 Server ME Configuration 51 3 6 Socket Configuration 5...

Page 8: ...viii FWA8600 User Manual Appendix 95 A I O Port Address Map 96 B Interrupt Request Lines IRQ 99 C Watchdog Timer Configuration 100 ...

Page 9: ...1 Chapter 1 General Information The information provided in this chapter includes Features Packing List Optional Accessories Specifications Overview Dimensions ...

Page 10: ...ller The device comes with network interface card NIC slots to accommodate up to three IBN cards with 8x GbE ports each 3rd slot max 4 ports and one IBN P401Q card for a maximum of 25 GbE ports For I O connectivity and expansion features it offers a PCIe x8 slot an M 2 expansion slot to interface with SATA 3 0 and PCIe x4 bus for high data throughput as well as two USB 3 0 and an RJ45 serial conso...

Page 11: ... singly power supply or 300W 1 1 redundant power supply 1 3 Packing List Your product package should include the items listed below If any of the items below is missing contact the distributor or the dealer from whom you purchased the product Models with a single PSU FWA8600 x 1 Full Range 250W ATX Power Supply x 1 Power Cord 180 cm x 1 Rack Mount Bracket x 2 Models with 1 1 redundant PSU FWA8600 ...

Page 12: ...BN F200 2 x 25GbE SFP28 Non Bypass 1 5 Specifications Product Name FWA8600 NIC FWA8600 SHD FWA8600 SHQ System Motherboard MBN803 Operating System Windows 10 64 bit Linux Ubuntu 16 04 1 CPU Intel Xeon D 2100 BGA2518 Chipset Integrated Memory 4 x DDR4 RDIMM up to 2666 MHz max 128 GB ECC or non ECC Storage 1 x 2 5 internal SATA drive bay 2 x 2 5 hot swappable SATA drive bays 4 x 2 5 hot swappable SAT...

Page 13: ... 05 lb Certificate CE FCC Class A Front I O Ports LCM 1 x LCM 16x2 dots with 4 keypads Console 1 x Console port Management Port MGMT 1 x MGMT ports Ethernet Port Up to 24 RJ45 GbE LAN ports 4 x network module slots Up to 20 RJ45 GbE LAN ports 3 x network module slots Up to 12 RJ45 GbE LAN ports 2 x network module slot USB 2 x USB 2 0 HDD N A 2 x 2 5 hot swappable SATA drive bays 4 x 2 5 hot swappa...

Page 14: ...4 158 F Relative Humidity 5 90 at 45 C non condensing Vibration Protection Operating 0 25 Grms 3 500 Hz Z axis Non operating 1 0 Grms 3 500 Hz Z axis Shock Protection Operating 20G 11ms X Y Z axis 3 lines in each axis Non operating 40G 11ms X Y Z axis test 3 lines in each axis All specifications are subject to change without prior notice ...

Page 15: ...No Name No Name 1 LCM Display with 4 buttons 5 2 USB 2 0 Ports 2 4 10GbE SFP Ports Optional 6 Console Port 3 Network Modules 2 5 Hot swappable Drive Bays 7 User Self Defined GPIO Button 4 Management Port 8 LED Indicators From top to bottom Status HDD Power Oblique View ...

Page 16: ... Single Power Supply Unit Redundant Power Supply Unit No Name No Name 1 PCIe x8 Expansion Card Slot 4 Power Switch 2 System Fan Modules 5 Single Power Supply Unit 3 VGA Port via the optional IPMI module 6 Reduntant Power Supply Unit ...

Page 17: ...General Information FWA8600 User Manual 9 1 1 7 Dimensions Unit mm ...

Page 18: ...10 Chapter 2 Hardware Configuration The information provided in this chapter includes Installation Replacement Information and locations of connectors ...

Page 19: ...ing the device cover For memory M 2 PCIe expansion card or the optional IPMI module you need to remove 8 screws as shown below to pull out the lid This is illustrated by the example of FWA8600 NIC Configuration inside Refer to the figure below for the intenal areas to install additional 2 5 HDD SSD NIC modules and expansion card Area A accommodates NIC modules or 2 5 how swappable HDD SSD Area B s...

Page 20: ...pull it out carefully as shown below for replacement and installation 2 1 2 HDD or SSD FWA8600 SHD FWA8600 SHQ hot swappable HDD SSD 1 Push the latch outwards to release and take out the HDD tray 2 Remove the 4 screws on both lateral sides of the HDD tray Install your HDD and tighten the screws ...

Page 21: ... as indicated below to release the internal 2 5 HDD SSD and the bracket 2 Unplug the SATA power and data cable and remove the 4 screws from the holder bracket for each HDD SSD for replacement 3 Take out the HDD SSD and install a new one onto the tray Fasten the 4 screws back for each HDD SSD 4 Secure the HDD SSD and the bracket back to the system ...

Page 22: ... slot down and outwards with your fingertips 2 Hold the memory module and align the key of the module with that on the memory slot 3 Gently push the module in an upright position until the ejector tabs of the memory slot close to hold the module in place when the module touches the bottom of the slot To remove the module press the ejector tabs outwards with your fingertips to eject the module ...

Page 23: ...PMI modules are optional items 1 Locate the IPMI slot and align the key of the module with that on the slot 2 Insert the module slantwise and gently push the module straight down until the clips of the slot close to hold the module in place when the module touches the bottom of the slot To remove the module press the clips outwards with your thumb and index finger of both hands ...

Page 24: ...take out the fan to replace with a new one and tighten the screws 2 1 6 Redundant Power Supply Unit If you need to install or replace a redundant power supply unit push the latch downwards first Grasp the handle pull the PSU out carefully and replace it with a new one 2 2 Pinout for Console Port Pin Signal Name Pin Signal Name 1 RTS 5 Ground 2 DTR 6 RXD 3 TXD 7 DSR 4 Ground 8 CTS ...

Page 25: ...ng of several metal pins with a non conductive base mounted on the circuit board Jumper caps are used to have the functions and features enabled or disabled If a jumper has 3 pins you can connect either PIN1 to PIN2 or PIN2 to PIN3 by shorting Refer to the illustration below to set jumpers Pin closed Oblique view Schematic illustration Open 1 2 2 3 When two pins of a jumper are encased in a jumper...

Page 26: ...18 FWA8600 User Manual 2 4 Jumper Connector Locations on Motherboard Motherboard MBN803 ...

Page 27: ... 5 Jumper Quick Reference Function Connector Name Page AT ATX Mode JP8 19 Clearing CMOS Data JP3 20 Clearing ME Register JP9 21 Factory Use Only JP1 JP5 JP6 2 5 1 AT ATX Mode JP8 Function Pin closed Illustration AT Mode Default 1 2 ATX Mode 2 3 1 1 1 ...

Page 28: ...20 FWA8600 User Manual 2 5 2 Clearing CMOS Data JP3 Function Pin closed Illustration Normal Default 1 2 Clearing CMOS 2 3 1 1 1 ...

Page 29: ...Hardware Configuration FWA8600 User Manual 21 2 2 5 3 Clearing ME Register JP9 Function Pin closed Illustration Normal Default 1 2 Clearing ME Register 2 3 1 1 1 ...

Page 30: ...Connector SATAPWR1 SATAPWR2 SATAPWR3 SATAPWR4 27 SATA RAID Key J5 27 SATA III Port SATA1 SATA2 SATA3 SATA4 10 GbE Port Mini SAS HD type J6 10 GbE LED Port J7 Socket for BIOS Chip J9 IPMI Connector 2 J13 DDR4 Memory Slot DIMMA1 DIMMB1 DIMMD1 DIMME1 M 2 M2280 Slot J21 PCIe x8 Slot Standard GF_PCIE4 3 For IBN Card only GF_PCIE1 GF_PCIE2 GF_PCIE3 Factory Use Only J1 J2 J5 J8 J10 J12 J17 J20 1 Applicab...

Page 31: ...ignment Pin Assignment 1 Ground 3 VCC12 2 Ground 4 VCC12 ATX1 Pin Assignment Pin Assignment 1 VCC3_3 13 VCC3_3 2 VCC3_3 14 12V 3 Ground 15 Ground 4 VCC5 16 ATX_PSON _Q 5 Ground 17 Ground 6 VCC5 18 Ground 7 Ground 19 Ground 8 Power good 20 5V 9 5VSB_PS 21 VCC5 10 VCC12 22 VCC5 11 VCC12 23 VCC5 12 VCC3_3 24 Ground 3 4 1 2 1 13 24 12 ...

Page 32: ...gnal Name 1 ATX_PSON _EN_R 2 Ground 2 6 3 Front Panel Setting Connector J16 Pin Signal Name Pin Signal Name 1 VCC5 2 SPEAKER 3 NC 4 NC 5 Ground 6 NC 7 NC 8 NC 9 5VDUAL 10 5VDUAL 11 5VDUAL 12 5VDUAL 13 Ground 14 ATXPWR_BTN 15 NC 16 NC 17 Ground 18 FRST_OUT 19 VCC3_3 20 HDD_LED 1 1 19 20 2 ...

Page 33: ...ignal Name Pin Signal Name 1 SMB_PWR_5VDUAL_CLK 4 Ground 2 SMB_PWR_5VDUAL_DAT 5 VCC3_3 3 PL_SMB Alert 2 6 5 Digital I O Connector J8 Pin Signal Name Pin Signal Name 1 Ground 2 VCC5 3 INT0_SIOGP22 4 INT0_SIOGP25 5 INT0_SIOGP23 6 INT0_SIOGP26 7 INT0_SIOGP24 8 INT0_SIOGP27 1 2 8 7 ...

Page 34: ...Reserved Pin Signal Name Pin Signal Name 1 SMB_IPMB_STBY_LVC5_DATA 3 SMB_IPMB_STBY_LVC5_CLK 2 Ground 4 P5V_STBY 2 6 7 Fan Connector FAN1 FAN2 FAN3 FAN1 FAN2 FAN3 Pin Signal Name Pin Signal Name 1 SYSFAN_G 3 SYSFAN_RPM 2 SYSFAN_12V 4 SYSFAN_PWM 1 ...

Page 35: ...ctor SATAPWR14 SATAPWR24 SATAPWR34 SATAPWR44 From left to right SATAPWR14 SATAPWR24 SATAPWR34 SATAPWR44 Pin Signal Name Pin Signal Name 1 VCC5 3 Ground 2 Ground 4 VCC12 2 6 9 SATA RAID Key J5 Pin Signal Name Pin Signal Name 1 Ground 3 Ground 2 P3V3_AUX 4 SATA_RAID_KEY 1 1 ...

Page 36: ...hapter describes the different settings available in the AMI BIOS that comes with the board The topics covered in this chapter are as follows Main Settings Advanced Settings Chipset Settings Security Settings Boot Settings Save Exit ...

Page 37: ... Test will continue with its test routines thus preventing you from invoking the Setup If you still need to enter Setup restart the system by pressing the Reset button or simultaneously pressing the Ctrl Alt and Delete keys You can also restart by turning the system Off and back On again The following message will appear on the screen Press DEL to Enter Setup In general press the arrow keys to hig...

Page 38: ... Description Option UTOPIA Allows you to choose Optimized or Show All Items BIOS Setting Description System Date Sets the date Use the Tab key to switch between the data elements System Time Set the time Use the Tab key to switch between the data elements ...

Page 39: ...BIOS Setup FWA8600 User Manual 31 3 3 4 Advanced Settings This section allows you to configure improve your system and allows you to set up some system features according to your preference ...

Page 40: ... Disables SHA 1 PCR Bank SHA256 PCR Bank Enables Disables SHA256 PCR Bank Pending Operation Schedule an operation for the security device Note Your computer will reboot during restart in order to change state of security device Options None TPM Clear Platform Hierarchy Enables Disables Platform Hierarchy Storage Hierarchy Enables Disables Storage Hierarchy Endorsement Hierarchy Enables Disables En...

Page 41: ...PM 1 2 or 2 0 will restrict support to TPM 1 2 or 2 0 devices Auto will support both with the default sest to TPM2 0 devices if not found 3 4 2 ACPI Settings BIOS Setting Description Enable ACPI Auto Configuration Enables Disables BIOS ACPIU auto configuration Enable Hibernation Enables Disables the system ability to hibernate OS S4 Sleep State This option may not be effective with some OS Lock Le...

Page 42: ...ual 3 4 3 NCT5523D Super I O Configuration BIOS Setting Description Serial Ports Configuration Sets Parameters of Serial Ports You can enable disable the serial port and select an optimal settings for the Super IO device ...

Page 43: ...Description Serial Port Sets parameters of Serial Ports COM Change Settings Selects an optimal settings for the Super I O device Options Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 ...

Page 44: ...tion Serial Port Sets parameters of Serial Ports COM Change Settings Selects an optimal settings for the Super I O device Options Auto IO 2F8h IRQ 3 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 ...

Page 45: ...tion Smart Fans Control This field enables or disables the smart fan control Options Disabled 40 C 45 C 50 C 55 C Temperatures Voltages Fan Speed These fields are the parameters of the hardware monitoring function feature of the motherboard The values are read only as monitored by the system and showing the PC health status ...

Page 46: ...ings The settings specify how the host computer and the remote computer which the user is using will exchange data Both computers should have the same or compatible settings Sets parameters of Console Redirection Legacy Console Redirection Settings Allows you to configure the legacy console redirection settings Console Redirection Enables Disables console redirection ...

Page 47: ... lower speeds Options 9600 19200 38400 57600 115200 Data Bits Options 7 8 Parity A parity bit can be sent with the data bits to detect some transmission errors Even parity bit is 0 if the num of 1 s in the data bits is even Options None Even Odd Mark Space Stop Bits Stop bits indicate the end of a serial data packet A start bit indicates the beginning The standard setting is 1 stop bit Options 1 2...

Page 48: ... Key pad Select FunctionKey and keyPad on Putty Options VT100 LINUX XTERMR6 SC0 ESCN VT400 3 4 6 2 Legacy Console Redirection Settings BIOS Setting Description Redirection COM Port Selects a COM port to display redirection of Legacy OS and Legacy OPROM Messages Resolution On Legacy OS the number of rows and columns supported redirection Options 80x24 80x25 Redirect After POST When Bootloader is se...

Page 49: ...BIOS Setup FWA8600 User Manual 41 3 3 4 7 Network Stack Configuration BIOS Setting Description Network Stack Enables Disables UEFI Network Stack ...

Page 50: ...OM Options Force BIOS Keep Current INT19 Trap Response BIOS reaction on INT19 trapping by Option ROM Immediate executes the trap right away Postponed executes the trap during legacy boot HDD Connection Order Some OS require HDD handles to be adjusted i e OS is installed on drive 80h Options Adjust Keep Boot option filter Controls the priority of Legacy and UEFI ROMs Options UEFI and Legacy Legacy ...

Page 51: ...egacy Storage OpROM Options Do not lanuch UEFI Legacy Video Controls the execution of UEFI and Legacy Video OpROM Options Do not lanuch UEFI Legacy Other PCI devices Determines OpROM execution policy for devices other than network storage or video Options Do not lanuch UEFI Legacy 3 4 9 NVMe Configuration ...

Page 52: ...by XHCI driver USB Mass Storage Driver Support Enables Disables USB mass storage driver support USB Transfer time out Sets the time out value 1 5 10 or 20 sec s for Control Bulk and Interrupt transfers Device reset time out Sets the seconds 10 20 30 40 secs of delaying execution of start unit command to USB mass storage device Device power up delay The maximum time the device will take before it p...

Page 53: ...BIOS Setup FWA8600 User Manual 45 3 3 4 11 Intel R Virtual RAID on CPU 3 4 12 All CPU Information Displays all your CPU information ...

Page 54: ... Platform Configuration BIOS Setting Description Hidden Item Enables Disables the hidden items PCM Configuration Displays and provides option to change the PCM settings Server ME Configfuration Displays the ME configuration data ...

Page 55: ...nfiguration BIOS Setting Description PCH SATA Configuration Configures the SATA devices and settings PCH sSATA Configuration Configures the sSATA devices and settings USB Configuration USB devices and settings Networking Network devices and settings ...

Page 56: ...BIOS Setting Description SATA Controller Enables Disables SATA controller Configure SATA as Identify the SATA port is connected to SSD or HDD Options AHCI RAID SATA Ports Enables Disables SATA ports SATA Ports Hot Plug Enables Disables SATA ports hot plug ...

Page 57: ...on BIOS Setting Description sSATA Controller Enables Disables sSATA controller Configure sSATA as Identify the sSATA ports are connected to SSD or HDD Options AHCI RAID sSATA Ports Enables Disables SATA ports sSATA Ports Hot Plug Enables Disables SATA ports hot plug ...

Page 58: ...ector physical port XHCI Idle L1 Disabling XHCI Idle L1 to workaround USB3 hot plug will fail after 1 hot plug removal Please put the system to G3 for the new settings to take effect USB XHCI MSI Disable WA Enabling this item is to hide MSI capability on XHCI XHCI Over Current Pins Enables Disables support for XHCI over current pin mapping XHCI Wake On USB Enable Enables Disables the support for t...

Page 59: ...Description Altitude The altitude of the platform location above the see level expressed in meters The hex number is decoded as 2 s complement signed integer MCTP Bus Owner MCTP bus owner location on PCIe 15 8 bus 7 3 devices 2 0 function If all zeros sending bus owner is disabled ...

Page 60: ...d provides option to change the Common RefCode settings UPI Configuration Displays and provides option to change the UPI General Settings Memory Configuration Displays and provides option to change the Memory settings IIO Configuration Displays and provides option to change the IIO settings Advanced Power Management Configuration Displays and provides option ot change the Power Management settings...

Page 61: ...s Disables hyper threading Software Method to enable disable logical processor threads Intel Enahced Debug Enables Disables the function of Intel Enahced Debug Options Disable 4096K IED Trace Memory Option to allocate memory for PSMI trace Options Disable 4M 8M 16M 32M 64M 128M 256M 512M 1G TSEG SMRAM Size Option to change the size of SMRAM for TSEG Options 4M 8M 16M 32M 64M 128M Allow mixed freq ...

Page 62: ...ts the allocation size used to assign MMIOH resources Total MMIOH space can be up to 32xgranularity Options 1G 4G 16G 64G 256G 1024G Isoc Mode Enables Disables Isoc mode Numa Enables Disables Non uniform Memory Access NUMA Publish SRAT Enables Disables to publish the SRAT ACPI table to the OS SRAT Memory Hot Plug Fix for OS that does not support memory hot plug Example SuSE SLES10 SP2 This functio...

Page 63: ... UPI Configuration BIOS Setting Description UPI General Confguration Displays and provides option to change the UPI general settings UPI Per Socket Configuration Configures the UPI per socket UPI Dfx Configuration Configures UPI Dfx functions ...

Page 64: ...Speed Mode Select the UPI link speed as either the PDR speed Fast or default speed Slow Options Slow Fast Link Frequency Select Allows for selecting the UPI link frequency Options 9 6 GB s 10 4 GB s Auto User Per Link Setting Link L0p L1 Enable Enable the function to set as the C_10p_en Disable the function to reset it Auto decides based on S1 Compatibility UPI Failover Support Enable the function...

Page 65: ...ss_mem _rd_prefetch_rdcur Disable the function to reset it Auto decides based on the S1 compatibility UPI VNA Credit Override Global options UPI VNA credit override maximum minimum per link CRC Mode Allosw you to set the UPU CRC mode Options 16 Bit CRC 32 Bit Rolling CRC Auto sets to 16 bit UPI Load Board for Failed Links For debugging purposes UPI link will remain enabled for h w continuous train...

Page 66: ...58 FWA8600 User Manual 3 6 3 2 UPI Per Socket Configuration BIOS Setting Description CPU 0 CPU 0 configuration silk screen equivalent to CPU 1 ...

Page 67: ... Enable Auto LlcShareDrdCrd Enables Disables migration from SF to LLC and to leave shared lines in the LLC for Drd and Crd Options Disable Enable Auto CBo Bias Fwd Mode 0 Mode 0 Fwd only when Hom Req Default 1 Mode 1 Fwd when Hom Req Hom Local 2 Mode 2 Disable Bias Fwd Options Mode0 Mode1 Mode3 Mode4 Auto Snoop Fanout Options Disable Enable Auto Hit Me Enables Disables CHA HitME cache Options Disa...

Page 68: ...at there aren t enough snoop credits don t allocate IODC entry Options Disable Enable Auto Dual Link Interleave Mode Only valid in 2 socket 2 Link Topology Options Enable CHA interleaving disable SNC XOR based Intlv Disable D2C Auto Dfx System Degrade Mode System topology degrade mode options Options Degrade_to_1S Degrade_to_Supported No_Degrade VN1 Options Disable Enable Auto Direct to Core D2C O...

Page 69: ... MRC default setting Options Auto PDR Disable PPR Type Selects Post Package Repair type hard soft disabled Auto Sets it to the MRC default setting current default is disabled Options Auto Hard PPR Soft PPR PPR Disabled PPR Error Injection test Enables Disables support for c script err injection test Memory Frequency Maximum memory frequency selections in Mhz Options Auto 800 1000 1066 1200 1333 14...

Page 70: ...When disabled MRC will not use SPD bytes 90 95 for LRDIMM module delay When Auto is selected MRC will coundary check the values and use default values if SPD is 0 or out of range MemTest Enable Enables memory test during normal bootl Disable Disables this feature Auto Sets it to MRC deafult setting the current default is Enable Memory Type Selects the memory type supported by this platform Options...

Page 71: ...rected I O VT d configuratio menu Intel VMD Technology Press Enter to bring up the Intel VMD for volume management device configuration menu Intel AIC Retimer AIC SSD Technology non VMD Press Enter to bring up the Intel AIC Retimer AIC SSD Configuration menu IIO DFX Configuration Enables Disables DFX configuration PCIe Train by BIOS Assumes IIO is strapped for Malt for BIOS because straps are unre...

Page 72: ... Selects DMI Vc0 VCp writer selection as either allocating or non allocating or non allocating Auto enables POR setting Options Non Allocating Allocating PCIe Allocating Write Flows Selects Vc0 VCp writers selection for all CPU PCIe ports as either allocating or non allocating Auto enables POR setting Options Non Allocating Allocating Skip Halt On DMI Degradation Enables Disables this option to av...

Page 73: ...ices Options Disable Per Port L1 Only PCIE Stop Scream Support Enables Disables PCIe stop scream support Snoop Response Hold Off Sets Snoop Response Hold Off value 256 cycles as default PCIe Latency Tolerance Reporting Auto Disable Turns off the Latency Tolerance Report feature of the PCIe root port and endpoint Enable Turns on the Latency Tolerance Report feature PCIe Extended Tag Enable Auto Ena...

Page 74: ...I E completion Timeout Value Programs the completion timeout value D x F 0 0 88h B 3 0 where x is 0 3 Options 50μs to 10ms 16ms to 55ms 65ms to 210ms 260ms to 900ms 1s to 3 5s 4s to 13s 17s to 64s Sck0 RP Correctable Err Applies to root ports only Enables Disables interrupt on correctable errors Sck0 RP NonFatal Uncorrectable Err Applies to root ports only Enables Disables interrupt on a non fatal...

Page 75: ... PCIe port Options 6 0 dB 3 5 dB PCI E Port Clocking Configures port clocking via LNKCON 6 This refers to this components and the down stream component Options Distinct Common PCI E Port Max Payload Size Sets the max payload size to 256B if possible Options 128B 256B Auto PCI E Port D state Sets to D0 for normal operation D3Hot to be in low power state Options D0 D3Hot PCI E ASPM Support This opti...

Page 76: ...decoding P2P Memory Read Controls Peer2Peer memory read decoding PME to ACK Controls timeout usage for IIO waiting on PME_T0_ACK after a PME_TURN_OFF message Unsupported Request Controls the reporting of unsupported requests that IIO itself detects on requests its receives from a PCIe DMI port Alternate TxEq Enables Disables TxEq SRIS Enables Disables SRIS ECRC Enables or Disables ECRC Error Capab...

Page 77: ... 3 6 5 2 IOAT Configuration BIOS Setting Description Disable TPH Allows you to choose to disable TLP processing hint or not Options No Yes Prioritize TPH Enables Disables prioritize TPH Relaxed Ordering Enables Disables relaxed ordering ...

Page 78: ...70 FWA8600 User Manual 3 6 5 3 IIO General Configuration BIOS Setting Description IIO IOAPIC Stack 0 1 2 3 4 5 Enables Disables the IIO IOAPIC ...

Page 79: ... 3 6 5 4 Intel VT for Directed I O VT d BIOS Setting Description Intel VT for Directed I O VT d Enables Disables Intel Virtualization Technology for directed I O VT d by reporting the I O device assignment to VMM through DMAR ACPI tables ...

Page 80: ...Setting Description Intel VMD for Volume Management Device on Socket 0 Configures Intel VMD for PStack s BIOS Setting Description Intel VMD for Volume Management Device for PStack 0 1 2 Enables Disables Intel Volume Management Device Technology in this Stack ...

Page 81: ...6 5 6 Intel AIC Retimer AIC SSD Technology non VMD BIOS Setting Description Intel AIC Retimer AIC SSD HW at PStack 0 1 2 Anounce Intel AIC Retimer AIC SSD HW at PStack0 1 2 Port1A 1D Port2A 2D Port3A 3D Override IOU0 bifurcation if required ...

Page 82: ...gures Socket 0 DFX PCIe ports EV DFX Features Exposes IIO DFX devices and other CPU devices like PMON Ltssm Logger Enables Disables Ltssm Logger for PCIe functionality Jitter Logger Enables Disable Jitter Logger for PCIe functionality Socket 0 1 2 3 Device Hide Menu Displays Socket 0 1 2 3 device hide menu ...

Page 83: ...cluding Turbo XE etc Hardware PM State Control Controls the hardware PM state Overclocking Provide manual XE Ratio Limit setting CPU C State Control Sets the CPU C state setting Package C State Control Configures the C state setting CPU Thermal Management Manages the CPU thermal conditions CPU Advanced PM Tuning Sets the energy per Bias Pwr_Ctl PP0 Current SWLTD SAPM etc Package Current Config Pro...

Page 84: ...FIG Configuration Displays the PMAX configuration control sub menu ACPI Sx State Control Controls the ACPI Sx State individually Memory Power Thermal Configuration Displays and provides option to change the memory settings 3 6 6 1 CPU P State Control BIOS Setting Description WFR Uncore GV Rate Reduction Auto Enables the feature if WFT socket is detected in system Enable Always enables WFR Uncore G...

Page 85: ...SINGLE_PCTL Single PCTL mode makes all cores in the processor go to the most recent ratio request Single Power Domain SPD Single power domain aggregates the request from all cores and the highest request ratio is applied to all cores on the processor Boot Performance Mode Select the performance state that the BIOS Will set before OS hand off Options Max Performance Max Efficient Set by Intel Node ...

Page 86: ...cy is allowed to be Also impacts rate at which frequency drops when feature disengages Perf P Limit Clip Maximum value the floor is allowed to be set to for perf P Limit Perf P Limit Threshold Uncore frequency threshold above which this socket will trigger the feature and start trying to raise frequency of other sockets Perf P Limit Enables Disables performance P Limit ...

Page 87: ...tion EPP Enable When disabled HW masks EPP in CPUID 6 10 and uses EPB for EPP APS APS Rocketing Enables Disables the rocketing mechanism in the HWP p state selection pcode algorithm Rocketing enables the core ratio to Jump to max turbo instantaneously Scalability Enables Disables the use of scalability in HMP pcode power efficiency algorithms Scalability is the measure of estimated performance imp...

Page 88: ... Overclocking BIOS Setting Description Extreme Edition Enables Disables Extreme Edition support Overclocking Lock Enables Disables Overclocking LOT26 Enable For HEDT only select whether VR power is turned off to empty DIMM channels ...

Page 89: ...utonomous core C state CPU C6 report Enables Disables CPU C6 ACPI C3 report to OS Enahnced Halt State C1E Enables Disables core C1E auto promotion control Takes effect after reboot OS ACPI Cx Report CC3 CC6 to OS ACPI C2 or ACPI C3 PKGc Interrupt Response Time Programmable package C state interruption resonse time setup control ...

Page 90: ... to C3 Transition Timer PPDN_INIT 1 10 1 74 Bit 11 0 PKG C state Lat Neg MSR 1FCh Bit 30 PCH_NEG_DISABLE LTR IIO Input MSR 1FCh Bit 29 LTR_IIO_DISABLE Disable Innores IIO LTR input Options Take IIO LTR input Ingore IIO LTR input Latency Tolerence Requirement LTR Program CSR_SWLTROVRD 1 10 1 0x78 sub menu Plg C state SA Power Management Control MDLL Off Programs CSR_SAPMCTL 1 30 1 0xb0 sub menu MDL...

Page 91: ...tting this bit will lock in xxPROCHOT response configurations including ENABLE_BIDR_PROCHOT DIS_PROCHOT_OUT VR_THERM_ALERT_DISABLE and PROCHOT_LOCK PROCHOT Modes When a processor thermal sensor trips either core the PROCHOT will be driven Options Output only Disable Both Input and Output Input only Thermal Monitor Enables Disables thermal monitor ...

Page 92: ...84 FWA8600 User Manual 3 6 6 7 CPU Advanced PM Tuning BIOS Setting Description Energy Perf BIAS Displays the Energy Perf BIAS sub menu SAPM Control MAR 1FCh Bit 22 PWR_PERF_TUNING_DISABLE_SAPM_CTRL ...

Page 93: ...al 85 3 3 6 6 8 Package Current Config BIOS Setting Description Current Limit Override 0 Default do nothing 1 Manual override Current limitation in 1 8 A increments Lock Indication Enables Disables lock for CURRENT_LIMIT settings ...

Page 94: ...NCORE_PERF_PLIMIT_0VRD_EN Uncore Perf PLimit Override EET_OVERRIDE_ENABLE Enables Disables EET override IO_BW_PLIMIT_OVRD_EN Enables Disables IO BW PLimit override IOM_APM_OVERRIDE_ENABLE Enables Disables IOM APM override UPI_APM_OVERRIDE_ENABLE Enables Disables UPI APM override ...

Page 95: ...d to unlock the register Package RAPL Limit CSR Lock Enables Disables locking of package RAPL Limit MSR and a reset will be required to unlock the register PL1 Limit PL1 Power Limit PL1 Time Window Enables Disables PL1 If this option is disabled BIOS will program the default values for PL1 power limit and PL1 time window PL2 Limit PL2 Power Limit PL2 Time Window Enables Disables PL2 If this option...

Page 96: ...OS Setting Description PMAX Config Sign Controls whether PMAX config offset is a positive or negative value PMAX Config Offset Input decimal correction factor to program Valid input values are 0 to 15 Will be positive or negative based on PMAX Config Sign value ...

Page 97: ...BIOS Setup FWA8600 User Manual 89 3 3 6 6 12 ACPI Sx State Control BIOS Setting Description ACPI S3 Controls ACPI S3 state ACPI S4 Controls ACPI S4 state ...

Page 98: ...HOT input and output modes memhot sense therm throt or memhot output therm throt Options Disable Output only Input only Input and Output Enabled MEMHOT Output Throttling Mode Options Enables Disables the throt output high and low bit fields Options Disable Enable only temphi Enable only temphi mid Enable only temphi mid and low Memory Power Savings Advanced Options Advanced Settings for CKE and re...

Page 99: ...agement BIOS Setting Description BMC Support Enables Disables interfaces to communicate with BMC BMC SOL Function Enables Disables BMC SOL function Enable will inactive and clear IRQ and IObase of UART1 Disable keep original IRQ IObase and active UART1 ...

Page 100: ...92 FWA8600 User Manual 3 8 Security Settings BIOS Setting Description Administrator Password Sets an administrator password for the setup utility User Password Sets a user password ...

Page 101: ... key 65535 0xFFFF means indefinite waiting Bootup NumLock State Selects the keyboard NumLock state Quiet Boot Enables Disables Quiet Boot option Boot Mode Select Selects boot mode Legacy UEFI Boot Option Priorities Sets the system boot order Hard Disk Drive BBS Priorities Specifies the Boot Device Priority sequence from available Hard Disk Drives ...

Page 102: ...hanges Saves changes done so far to any of the setup options Discard Changes Discards changes done so far to any of the setup options Restore Defaults Restores Loads defaults values for all the setup options Save as User Defaults Saves the changes done so far as user defaults Restore User Defaults Restores the user defaults to all the setup options sSATA P2 Phison SSBP064GTMC0 Choose to save the c...

Page 103: ...Appendix This section provides the mapping addresses of peripheral devices and the sample code of watchdog timer configuration I O Port Address Map Interrupt Request Lines IRQ Watchdog Timer Configuration ...

Page 104: ...000000A0 0x000000A1 Programmable interrupt controller 0x0000C000 0x0000C01F Ethernet Controller 0x0000C000 0x0000C01F PCI Express Root Port 0x00000000 0x000002E7 PCI Express Root Complex 0x00000000 0x000002E7 Direct memory access controller 0x00000300 0x000003AF PCI Express Root Complex 0x000002E8 0x000002EF PCI Express Root Complex 0x000003E8 0x000003EF PCI Express Root Complex 0x00000400 0x00000...

Page 105: ...rboard resources 0x00000088 0x00000088 Motherboard resources 0x0000008C 0x0000008E Motherboard resources 0x00000090 0x0000009F Motherboard resources 0x000000A2 0x000000BF Motherboard resources 0x000000B1 0x000000B1 Motherboard resources 0x000000E0 0x000000EF Motherboard resources 0x000004D0 0x000004D1 Motherboard resources 0x0000040B 0x0000040B Motherboard resources 0x000004D6 0x000004D6 Motherboa...

Page 106: ...00900 0x0000090F Motherboard resources 0x00000910 0x0000091F Motherboard resources 0x0000FE00 0x0000FEFE Motherboard resources 0x00000061 0x00000061 System speaker 0x00000081 0x00000083 Direct memory access controller 0x00000087 0x00000087 Direct memory access controller 0x00000089 0x0000008B Direct memory access controller 0x0000008F 0x0000008F Direct memory access controller 0x000000C0 0x000000D...

Page 107: ...ort IRQ 4294967290 PCI Express Root Port IRQ 4294967289 PCI Express Root Port IRQ 4294967288 PCI Express Root Port IRQ 4294967287 PCI Express Root Port IRQ 5 PCI Encryption Decryption Controller IRQ 4294967285 AMD PSP 3 0 Device IRQ 4294967284 AMD PSP 3 0 Device IRQ 43 High Definition Audio Controller IRQ 4294967283 AMD USB 3 0 eXtensible Host Controller 1 0 Microsoft IRQ 4294967282 AMD USB 3 0 eX...

Page 108: ...efore the timer counts to zero 1 Sample Code The file NCT5523D H THIS CODE AND INFORMATION IS PROVIDED AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND OR FITNESS FOR A PARTICULAR PURPOSE ifndef __NCT5523D_H define __NCT5523D_H 1 define NCT5523D_INDEX_PORT NCT5523D_BASE define NCT5523D_DATA_PORT NCT5523D_BASE ...

Page 109: ...ude dos h include conio h include stdio h include stdlib h include NCT5523D H int main void void WDTInitial void void WDTEnable unsigned char void WDTDisable void int main void char SIO SIO Init_NCT5523D if SIO 0 printf Can not detect Nuvoton NCT5523D program abort n return 1 WDTInitial WDTEnable 10 WDTDisable return 0 void WDTInitial void unsigned char bBuf Set_NCT5523D_LD 0x08 switch to logic de...

Page 110: ...8 Set_NCT5523D_Reg 0x30 0x01 enable timer bBuf Get_NCT5523D_Reg 0xF0 bBuf 0x08 Set_NCT5523D_Reg 0xF0 bBuf count mode is second Set_NCT5523D_Reg 0xF1 NewInterval set timer void WDTDisable void Set_NCT5523D_LD 0x08 switch to logic device 8 Set_NCT5523D_Reg 0xF1 0x00 clear watchdog timer Set_NCT5523D_Reg 0x30 0x00 watchdog disabled ...

Page 111: ...T5523D_BASE void Unlock_NCT5523D void void Lock_NCT5523D void unsigned int Init_NCT5523D void unsigned int result unsigned char ucDid NCT5523D_BASE 0x4E result NCT5523D_BASE ucDid Get_NCT5523D_Reg 0x20 if ucDid 0xC4 NCT5523D goto Init_Finish NCT5523D_BASE 0x2E result NCT5523D_BASE ucDid Get_NCT5523D_Reg 0x20 if ucDid 0xC4 NCT5523D goto Init_Finish NCT5523D_BASE 0x00 result NCT5523D_BASE Init_Finis...

Page 112: ...EG_LD outportb NCT5523D_DATA_PORT LD Lock_NCT5523D void Set_NCT5523D_Reg unsigned char REG unsigned char DATA Unlock_NCT5523D outportb NCT5523D_INDEX_PORT REG outportb NCT5523D_DATA_PORT DATA Lock_NCT5523D unsigned char Get_NCT5523D_Reg unsigned char REG unsigned char Result Unlock_NCT5523D outportb NCT5523D_INDEX_PORT REG Result inportb NCT5523D_DATA_PORT Lock_NCT5523D return Result ...

Reviews: