background image

- 12 - 

Chapter 3 -    BarCode parameters setting 

 

How to set up a Code ID? 

(1)    Scan Start configuration bar code   

(2)    Go to the ASCII Table and scan label that represent the desired   

characters to be inserted. 

(3)    Scan Confirm configuration bar code   

(4)    Scan End configuration bar code. 

 

 

   

                               

 

    Start configuration                                            End configuration 

 

 

Confirm configuration 

 

3.1    UPC-A 

ITEM 

OPTION 

 

Disable 

Read 

 

* Enable 

Code ID Setting 

(Default : F ) 

 

Ref: Appendix (20-7EH) 

 

 

 

Summary of Contents for WBS-272MV

Page 1: ...Wireless Barcode Reader with Memory Vibration WBS 272MV...

Page 2: ...Suffix 7 2 3 Setup Insertion 8 Chapter 3 BarCode parameters setting 3 1 UPC A 12 3 2 UPC E 15 3 3 EAN 13 18 3 4 EAN 8 20 3 5 Code39 22 3 6 Codabar 25 3 7 Code93 29 3 8 Code128 31 3 9 Interleaved2 of...

Page 3: ...need to change these settings programming is accomplished by scanning the bar codes in this guide 1 2 How to set up the parameter I 1 Scan Start Configuration 2 Scan all necessary labels for parameter...

Page 4: ...e reads are needed to complete the configuration When use these special parameters In some cases you might need to read one or more barcodes such as Hexadecimal barcodes For example prefix suffix etc...

Page 5: ...6 Chapter 2 System setup Start configuration End configuration 2 1 Terminator ITEM OPTION None CR LF CR LF Tab Output Characters...

Page 6: ...t Prefix Code ID Bar Code Suffix How to set up a prefix To configure as prefix 1 Scan Start Configuration barcode 2 Scan Preamble bar code 3 Scan twice from FULL ASCII table 4 Scan Confirm configurati...

Page 7: ...This section describes how to setup the insertion of output NOTE Max 10 charters can be inserted each time Max Insertion group is only two Insertion group 01 or 02 can be used in different kinds of ba...

Page 8: ...u wish to place the character 6 Scan Start Configuration barcode 7 Scan G1 Character Position 8 Scan 0 and 3 from FULL ASCII Table which presents the position 9 Scan Confirm configuration barcode 10 S...

Page 9: ...amble Default 00 Ref Appendix Postamble Default 00 Ref Appendix G1 Insertion character Default 00 Ref Appendix G2 Insertion character Default 00 Ref Appendix G1 Character Position to be inserted Defau...

Page 10: ...racy Read 2 Times Negative bar codes Positive and negative bar codes Positive bar codes Code Type ID Code Type ID UPC A F Interleaved 25 N UPC E G Industrial 25 O EAN 13 H Matrix 25 P EAN 8 I China Po...

Page 11: ...to the ASCII Table and scan label that represent the desired characters to be inserted 3 Scan Confirm configuration bar code 4 Scan End configuration bar code Start configuration End configuration Con...

Page 12: ...TION Disable UPC A Expand to EAN 13 Enable Disable Check Digit Send Enable Disable Truncate Leading Zero Enable Truncate Leading Default 00 Ref Appendix 00 0DH Truncate Ending Default 00 Ref Appendix...

Page 13: ...14 Start configuration End configuration ITEM OPTION NONE 2 digits 5 digits 2 or 5digits Supplement digits Auto discriminate Supplement...

Page 14: ...15 3 2 UPC E Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default G Ref Appendix 20 7EH...

Page 15: ...ation ITEM OPTION Disable UPC E Expand to UPC A Enable Disable Check Digit Send Enable Truncate Leading Default 00 Ref Appendix 00 08H Truncate Ending Default 00 Ref Appendix 00 08H Insert group selec...

Page 16: ...17 Start configuration End configuration ITEM OPTION Disable Truncate Leading Zero Enable None 2 digits 5 digits 2 or 5 digits Supplement digits Auto discriminate Supplement...

Page 17: ...ation End configuration ITEM OPTION Disable Read Enable Code ID setting Default H Ref Appendix 20 7EH Disable Check Digit Send Enable Truncate Leading Default 00 Ref Appendix 00 0DH Truncate Ending De...

Page 18: ...iguration End configuration ITEM OPTION None 2 digits 5 digits 2 or 5 digits Supplement digits Auto discriminate Supplement Disable ISBN ISSN Conversion Enable Insert group selection Default 00 Ref Ap...

Page 19: ...4 EAN 8 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default I Ref Appendix 20 7EH Disable Check Digit Send Enable Truncate Leading Default 00 Ref Appendix 00...

Page 20: ...tion End configuration ITEM OPTION Truncate Ending Default 00 Ref Appendix 00 08H None 2 digits 5 digits 2 or 5 digits Supplement digits Auto discriminate Supplement Insert group selection Default 00...

Page 21: ...3 5 Code39 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default J Ref Appendix 20 7EH Disable Check sum verification Enable Disable Check sum transmission Ena...

Page 22: ...art configuration End configuration ITEM OPTION Disable Append Enable Min code length Default 00 Ref Appendix 00 32H Max code length Default 32H Ref Appendix 00 32H Standard Code39 Format Code 39 Full...

Page 23: ...End configuration ITEM OPTION Disable Transmit Start End Character Enable Truncate Leading Default 00 Ref Appendix 00 32H Truncate Ending Default 00 Ref Appendix 00 32H Insert group selection Default...

Page 24: ...25 3 6 Codabar Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default K Ref Appendix 20 7EH...

Page 25: ...26 Start configuration End configuration ITEM OPTION Disable Check sum verification Enable Disable Check sum transmission Enable Disable Append Enable Truncate Leading Default 00 Ref Appendix 00 7EH...

Page 26: ...guration End configuration ITEM OPTION Truncate Ending Default 00 Ref Appendix 00 7EH ABCD ABCD abcd abcd Start End type abcd tn e Disable Start End transmission Enable Min code length Default 05 Ref...

Page 27: ...28 Start configuration End configuration ITEM OPTION Max code length Default 3CH Ref Appendix 00 3CH Insert group selection Default 00 Ref Appendix 00 02H...

Page 28: ...29 3 7 Code93 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default L Ref Appendix 20 7EH Disable Check sum verification Enable...

Page 29: ...Check sum transmission Enable Min code length Default 00 Ref Appendix 0 50H Max code length Default 50H Ref Appendix 0 50H Truncate Leading Default 00 Ref Appendix 00 7EH Truncate Ending Default 00 R...

Page 30: ...31 3 8 Code 128 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default M Ref Appendix 20 7EH Disable Check sum verification Enable...

Page 31: ...32 Start configuration End configuration ITEM OPTION Disable Check sum transmission Enable Disable FNC2 Append Enable Disable UCC EAN128 Enable Disable FNC1 transmission Enable...

Page 32: ...ACTER Enable Field Separator Ref Appendix Truncate Leading Default 00 Ref Appendix 00 7FH Truncate Ending Default 00 Ref Appendix 00 7FH Min code length Default 00 Ref Appendix 00 7FH Max code length...

Page 33: ...nterleaved 2 of 5 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default N Ref Appendix 20 7EH Disable Check sum verification Enable Disable Check sum transmissi...

Page 34: ...TION Truncate Leading Default 00 Ref Appendix 00 7EH Truncate Ending Default 00 Ref Appendix 00 7EH Min code length Default 04 Ref Appendix 04 7FH Max code length Default 7FH Ref Appendix 00 7FH Inser...

Page 35: ...2 of 5 Start configuration End configuration ITEM OPTICON Disable Read Enable Code ID setting Default O Ref Appendix 20 7EH Min code length Default 00 Ref Appendix 00 32H Max code length Default 32H...

Page 36: ...on ITEM OPTION Truncate Leading Default 00 Ref Appendix 00 32H Truncate Ending Default 00 Ref Appendix 00 32H Disable Check sum verification Enable Disable Check sum transmission Enable Insert group s...

Page 37: ...38 3 11 Matrix 2 of 5 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default P Ref Appendix 20 7EH Disable Check sum verification Enable...

Page 38: ...sum transmission Enable Truncate Leading Default 00 Ref Appendix 00 50H Truncate Ending Default 00 Ref Appendix 00 50H Min code length Default 0B Ref Appendix 00 50H Max code length Default 50H Ref Ap...

Page 39: ...CHINA POSTAL CODE Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default Q Ref Appendix 20 7EH Disable Check sum verification Enable Disable Check sum transmissi...

Page 40: ...TION Truncate Leading Default 00 Ref Appendix 00 50H Truncate Ending Default 00 Ref Appendix 00 50H Min code length Default 00 Ref Appendix 00 50H Max code length Default 50H Ref Appendix 00 50H Inser...

Page 41: ...42 3 13 MSI Plessey Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default R Ref Appendix 20 7EH Disable MOD 10 MOD 10 10 Check sum verification MOD 11 10...

Page 42: ...sum transmission Enable Truncate Leading Default 00 Ref Appendix 00 3CH Truncate Ending Default 00 Ref Appendix 00 3CH Min code length Default 00 Ref Appendix 00 3CH Max code length Default 3CH Ref Ap...

Page 43: ...3 14 CODE 32 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID Setting Default S Ref Appendix 20 7EH Disable Check sum verification Enable Disable Check sum transmission En...

Page 44: ...45 Start configuration End configuration ITEM OPTION Truncate Leading Default 00 Ref Appendix 00 0AH Truncate Ending Default 00 Ref Appendix 00 0AH Insert group selection Default 00 Ref Appendix 00 02...

Page 45: ...46 3 15 CODE 11 Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default T Ref Appendix 20 7EH Disable Check sum verification Enable...

Page 46: ...sum transmission Enable Truncate Leading Default 00 Ref Appendix 00 50H Truncate Ending Default 00 Ref Appendix 00 50H Min code length Default 00 Ref Appendix 00 50H Max code length Default 50H Ref Ap...

Page 47: ...3 16 Telepen Start configuration End configuration ITEM OPTION Disable Read Enable Code ID setting Default V Ref Appendix 20 7EH Disable Check sum verification Enable Only Numnic Data Format Full ASC...

Page 48: ...sum transmission Enable Truncate Leading Default 00 Ref Appendix 00 40H Truncate Ending Default 00 Ref Appendix 00 40H Min code length Default 00 Ref Appendix 00 40H Max code length Default 40H Ref Ap...

Page 49: ...50 3 17 GS1 Data Bar RSS Start configuration End configuration ITEM OPTION Enable RSS 14 Disable Enable RSS 14 LIMITED Disable Enable RSS 14 EXPANDED Disable Enable RSS TO UPC EAN Disable...

Page 50: ...51 Start configuration End configuration ITEM OPTION Enable APPLICATION ID TRANSMISSION Disable Enable CHECKSUM TRANSMISSION Disable...

Page 51: ...52 Appendix A...

Page 52: ...6 F V f v 7 BEL Left ETB F7 7 G W g w 8 BS Backspace CAN F8 8 H X h x 9 HT TAB EM F9 9 I Y i y A LF LF SUB F10 J Z j z B VT Right ESC F11 K k C FF PageUp FS F12 L l D CR Enter GS ESC M m E SO PageDown...

Page 53: ...HT 41 29 10 0A LF 42 2A 11 0B VT 43 2B 12 0C FF 44 2C 13 0D CR 45 2D 14 0E SO 46 2E 15 0F SI 47 2F 16 10 DLE 48 30 0 17 11 DC1 49 31 1 18 12 DC2 50 32 2 19 13 DC3 51 33 3 20 14 DC4 52 34 4 21 15 NAK...

Page 54: ...3 49 I 105 69 i 74 4A J 106 6A j 75 4B K 107 6B k 76 4C L 108 6C l 77 4D M 109 6D m 78 4E N 110 6E n 79 4F O 111 6F o 80 50 P 112 70 P 81 51 Q 113 71 q 82 52 R 114 72 r 83 53 S 115 73 s 84 54 T 116 74...

Page 55: ...56 Table Hex HEXADCIMAL Confirm configuration End Configuration...

Page 56: ...rademarks logos brands product names are properties of their respective owners Warranty All iBall products are governed by iBall Warranty terms Refer www iball co in for details For any technical help...