ibaRackline-PC CAM/HD
Manual
Issue 1.1
13
5.4
Error monitoring
ibaOut-Temp card installed illustrated by ibaRackline-PC
The temperature and the status of the power supply unit can be monitored with the slot
cards ibaOut-Temp and ibaOut-State. The cards can be ordered separately. If one of the
cards is ordered with a PC, it is installed by default in slot X20. If you want to install the
card later on, refer to chapter 7.4.
The status of temperature and power supply unit are indicated each with a bicolored LED
on the cards.
LED
Status
Description
TEMP
green
red
Temperature OK
Overtemperature
POWER green
red
Power supply OK
Power supply error
Redundant power supply: error in one of the two power
supply units
5.4.1
ibaOut-Temp
ibaOut-Temp provides two relay outputs for temperature and power supply (2-pin con-
nector), which can be used to indicate errors. Both error types are indicated separately.
The switch position of the outputs is as follows:
Status
Switch POWER
Switch TEMP
Power off or power error
closed
open
Power OK, temperature OK
open
open
Power OK, overtemperature
open
closed
Contact loading capacity
Nominal current: 400 mA
Nominal voltage: 60 V
Compatibility to previous models
ibaRackline computers of older series only provide one relay output for error indication.
The relay contact is closed when an error occurs, without differentiating between over-
temperature or a power supply error.