Manual
ibaPADU-8AI-U/-8AI-I
22
Issue 1.6
9
Configuration
The description of the device configuration is based on ibaPDA.
9.1
Configuration in ibaPDA
Set the desired device mode with the rotary switch S2 before initial operation, see also
chapter 7.4.2 “Rotary switch S2”.
The familiar program interface of the previous devices is retained for ibaPADU-8AI.
9.1.1
First steps
1.
Start the ibaPDA client and open the I/O Manager.
2.
Choose the correct ibaFOB-D input card in the signal tree (on the left hand side) and
mark the link ibaPADU-8AI is connected to. Right-click on the link and choose “Auto-
detect”.
Note: The autodetect function is not possible with ibaPADU-8AI-I. Therefore the de-
vice must manually be added, continue with step 3.
ibaPDA recognizes the device automatically. The device will be listed in the signal
tree.
Note
If there are several devices in a chain, only the device which is furthest from the
ibaPDA system will be detected with the “Autodetect” function. This is independent
from the device address set at the device. The other devices must manually be
added.