ibaMS4xAI-380VAC
Manual
Issue 1.5
21
Locked
True: the module can only be changed by an authorized user.
False: the module can be changed by any user.
Enabled
Data capturing for this module is enabled.
Name
You can enter a name for the module.
Modul No.
Consecutive module number assigned by ibaPDA for clearly referencing the sig-
nals, e.g. in expressions or ibaAnalyzer. The number can be changed by the user.
Timebase
Timebase, specified in the PADU-S module.
Use name as prefix
Prefix the signal names of this module with the module name.
Configuration set by
This item is only visible when ibaPADU-S-IT-2x16 is used as central unit. When an
embedded application has been started on ibaPADU-S-IT-2x16 (e. g. ibaLogic),
then ibaPDA cannot modify the configuration of the modules and signals. In this
case the configuration is set by the embedded application. The following entries can
be displayed:
ibaPDA
When ibaPDA is displayed, an embedded application has not been started and
the configuration can be set by ibaPDA.
Embedded application
When embedded application is displayed, the configuration of the modules and
signals is set by the embedded application on the device. In this case it is possi-
ble to import user-defined signal names, which are configured in the embedded
application, provided that the embedded application supports this function (Import
signal names: True).
The modules and signals configured by the embedded application cannot be con-
figured in ibaPDA, they are displayed in gray in the respective fields.
The configuration is read by ibaPDA and used for the acquisition. Modules and
signals which are not displayed in gray can be used in ibaPDA.
Advanced
Digital filter mode
When you select „Anti-aliasing“ then after the analog anti-aliasing filter an additional
digital anti-aliasing filter is applied to the signals. This digital anti-aliasing filter can
be enabled only once per module and is then applied to all signals, that have the
filter property enabled on the “Analog” tab. This means, that the digital anti-aliasing
filter can only be activated together with the analog filter by activating the filter op-
tion on the “Analog” tab.
The digital anti-aliasing filter can only be enabled, when the sampling rate > 500 Hz
(= timebase < 2 ms).
When the digital filter is enabled, an additional field „Cutoff frequency“ appears.