Technical data 

10.1 

Main data 

 

Order No.  

11.112701 

Format/size 

PCI Express card 

Operating Temperature 

From 32 °F to 122 °F (from 0 

°

C to 50 

°

C) 

Storage Temperature 

From -13 °F to 158 °F (from -25 

°

C to 70 

°

C) 

Transport Temperature 

From -13 °F to 158 °F (from -25 

°

C to 70 

°

C) 

Cooling 

Passive 

Power Supply  

Via PCIe 1.0-x1-compatible slot 

Current consumption SLM 

Up to 950 mA 

FO cable 

Coupling 

62.5/125 µm 

ST Lean 

Distance between 2 devices 

Up to 1,312 ft. (400 m ) without repeater 

Weight (incl. Packaging and  
Documentation) 

0.44 lb (200 g) 

Number of SD connections 

1 (duplex) 

Data transmission rate 

96 Mbit/s 

Fastest sample time 

1 ms 

 
 

Summary of Contents for FOB-SDexp

Page 1: ...ibaFOB SDexp Manual Issue 1 1 3 ibaFOB SDexp Interface Board for SIMADYN D Manual Issue 1 1 ...

Page 2: ...iance is not guaranteed However the information in this publication is updated regularly Required corrections are contained in the following regulations or can be down loaded on the Internet The current version is available for download on our web site http www iba ag com Protection note Windows is a label and registered trademark of the Microsoft Corporation Other prod uct and company names menti...

Page 3: ...icators 11 5 6 1 Device LEDs 11 5 6 2 7 Segment display 12 5 7 Fiber optic interface 12 6 Mounting and dismounting 13 6 1 Safety information 13 6 2 Mounting 13 6 3 Dismounting 13 7 Configuration 14 7 1 Configuration on the control unit 14 7 1 1 SD TDC lite transmission channels 14 7 1 2 SD TDC lite reception channels 17 7 1 3 Technostring 17 7 1 4 Time synchronization 18 7 2 Configuration in ibaPD...

Page 4: ... 8 2 Link diagnostics 28 8 2 1 Configuration tab 28 8 2 2 System Info tab 29 8 2 3 Timing tab 30 8 2 4 Active data channels tab 31 8 2 5 Channels in system tab 31 8 2 6 Memory view tab 32 9 Synchronization of iba cards 33 9 1 Important information 33 9 2 Procedure 33 10 Technical data 34 10 1 Main data 34 10 2 Performance 35 11 Support and Contact 36 ...

Page 5: ...he is capable of assessing safety and recognizing possible consequences and risks on the basis of his her specialist train ing knowledge and experience and knowledge of the standard regulations 1 2 Notations In this manual the following notations are used Action Notation Menu command Menu Logic diagram Call of menu command Step 1 Step 2 Step 3 Step x Example Select menu Logic diagram Add New logic...

Page 6: ... the system or machine to be controlled there is a risk of death or severe injury The non observance of this safety information may result in a potential risk of death or severe injury The non observance of this safety information may result in a potential risk of injury or material damage Note A note indicates special requirements or actions to be observed Important information Information that a...

Page 7: ... computer before opening This board contains components which can be destroyed by electrostatic discharge Prior to touching any electronics board your body must be electrically discharged This can be simply done by touching a conductive grounded object immediately beforehand e g bare metal cabinet components socket protective conductor contact 4 System requirements 4 1 Hardware IBM PC compatible c...

Page 8: ... communicate with the master and other slaves The ibaPDA PC with an ibaFOB SDexp card acts like a slave rack in the SIMADYN D system the ibaFOB SDexp card acts like a CS22 This topology enables the ibaFOB SDexp to communicate in theory with every processor in one of the connected racks max 7 or the master rack This would be up to 64 CPUs Figure 1 Example of configuration with ibaPDA By means of th...

Page 9: ...e to be manually programmed in the con trol unit Changes of signals require a change in this program Up to 16 process tel egrams are to be defined per card which transport the values to ibaPDA containing 32 analog plus 32 digital variables each Structure and length of the process tele grams are determined by ibaPDA Up to 4 cards in a PC are supported by ibaPDA In addition the ibaPDA Technostring n...

Page 10: ...ce function blocks required for the request function are included in the iba function block library FBAPDA You will find the library on the DVD ROM delivered with ibaPDA Other documentation The configuration of the request function is described in the ibaPDA Request SD TDC manual 5 4 Front view 1 7 segment display 2 Status LEDs 3 FO connector receiver 4 FO connector transmitter Figure 2 Front view...

Page 11: ...or a few seconds to prove their proper function LED Status Indication green Off Blinking Card is dead or defect Normal operation yellow Off Blinking On No signals detected fiber optics not connected or sending device is switched off Connection ok but SD system not ready Connection ok SD system ready white Off On No data transfer Data transfer in progress red Off Blinking On Normal state Running in...

Page 12: ...he decimal dot ON Card is configured as an internal interrupt master The decimal dot blinking Card is configured as an external interrupt master The decimal dot OFF Card is configured as an interrupt slave Important note It is not allowed to configure the ibaFOB SDexp as external interrupt master 5 7 Fiber optic interface The ibaFOB SDexp board provides 2 ST type jacks 1 optical transmitter TX whi...

Page 13: ...he card carefully out of the package Use a grounding cable or discharge any electrostatic charge before taking the card No wiring or jumpering is necessary 4 Grab the card at the front plate and the rear upper corner Do not touch the contacts 5 Plug in the card carefully into a free PCIe slot and fix the card to the housing of the PC 6 If more than one iba card is installed connect all cards with ...

Page 14: ...ls are to be projected as process data channels in the REFRESH or MULTIPLE channel mode Important information All channels must support the same channel mode either all REFRESH or all MULTIPLE The channels can be on different processors The CTS connectors of the transmis sion function blocks must indicate the rack link component to which ibaFOB SDexp is also connected CS14 or CP53M0 The channels c...

Page 15: ...ibaFOB SDexp Manual Issue 1 1 15 Figure 4 Configuration transmission channel with CTV ...

Page 16: ...or Value Description CTS Connection to board Component name of CS14 resp CP53M0 AT M0PDADAT Name of the transmission channel MOD R REFRESH channel mode EN 1 Transmits the cycle of the time slice NBY 132 Telegram length in bytes PTR Pointer on telegram buffer which must be connected to the PTR connector of the DWR xx function blocks ...

Page 17: ...each rack link However beyond the rack link you have the possibility of transmitting other technostrings e g via TCP IP or serial interface The channel characteristics are defined as follows ibaPDA Technostring Channel name PDA_ASCI Channel length 512 Byte Data format Unformatted alphanumeric character string Channel mode Handshake Use Transmission of strip attributes technology and material relat...

Page 18: ...ock in the fastest sampling time 5 ms This function block supplies a digital DCF77 signal with polarity 0 active Put it on a bit of a SD TDC lite telegram The function block is contained in the FBAPDA function block library of iba AG If you require more information please contact the support of iba AG Figure 6 Configuration DCF77 time signal Alternatively the synchronization can be done with an IE...

Page 19: ...ed as Interrupt Master The Slave Mode is activated for ibaFOB SDexp In case the ibaFOB D card is not being used but several ibaFOB SD exp or ibaFOB TDC exp cards are activated the mode Interrupt Master intern can be defined for one of these cards As a result this card will generate the inter rupt for the other cards Interrupt Slaves The interrupt will be transmitted to these iba cards via the sync...

Page 20: ..._BgtName under HKLM SYSTEM CurrentControlSet Service PdaDrv BG name of FOB SDexp link With this name iba FOB SDexp logs in on the rack link as BG The default setting is the ibaPDA license number limited to 6 characters Important note If there are several ibaPDA systems connected to a computer coupling you have to enter different BG names The name of the connection needs to be unique within the rac...

Page 21: ...ff ibaPDA keeps running with the last received values frozen With this option you can restart ibaPDA after the deactivated rack is available again Note ibaPDA will not be restarted after the restart of another ibaPDA or ibaQDR system which is connected to the same CS14 if the BGT name of this system is PDA00x x 1 9 For description of other tabs please refer to chapter 8 2 Link diagnostics 7 2 3 Co...

Page 22: ...ernal reference number of the module Time base Here all signals of the module are captured The time base should be adjusted to the configured time slice of the transmission block of the control unit multiple of general ibaPDA acquisition cycle time Use name as prefix Prefix the signal names of this module with the module name Channel You can select the channel name M0PDADAT MFPDADAT Note If you cl...

Page 23: ...signal Two additional comments can be defined for each signal by clicking on the icon Unit Here you can specify a physical unit Gain Offset For analog values there is the possibility of scaling the measured raw values to physical values Active Here you can select a specific captured value Actual Display of current variable raw values in numerical representation Other documentation You will find a ...

Page 24: ...ech nostring reception and the data processing After entry of the standard parameters the following settings must be defined Entry of terminator character according to the Technostring definition in chapter 7 1 3 Technostring default is 13 CR Selection of board type ibaFOB SD or ibaFOB SDexp Figure 13 ConfigurationTechnostring Other documentation For a more detailed description of the Technostring...

Page 25: ...polarity to Log 0 After two minutes the time of ibaPDA and the time of the SIMATIC TDC resp SIMADYN D system is synchronized Figure 14 Time synchronization with DCF77 signal If required you can specify an additional DCF77 signal on a CPU of another rack This secondary signal only becomes active if the CPU on which you have projected the pri mary DCF77 signal fails Synchronization with IEC 1131 tim...

Page 26: ... Select the time synchronization with IEC 1131 in the ibaPDA I O manager In the pick lists IEC 1131 time signal and Microsecond signal select the calcu lated virtual signals 99 4 IEC time seconds and 99 5 IEC time microseconds Figure 16 Time synchronization with IEC 1131 time signal ...

Page 27: ... and memory address IO and memory length are displayed here If these fields are empty or contain implausible data the card is not properly plugged into the PCI slot Schematic depiction The graphic depiction of the card is dynamic i e the 7 segment display with the card number and the LEDs for the connection status reflect the same status that can be seen on the card itself The displays and their m...

Page 28: ...ry region can be selected in the pick list Memory region In the context menu opened by a right mouse click you can enter the memory address as a decimal or hexadecimal number and you can freeze the display 8 2 Link diagnostics Other documentation For a more detailed description of the following card diagnostics dialogs please refer to the ibaPDA Request SD TDC manual 8 2 1 Configuration tab On the...

Page 29: ...r and max access time System diagnostics shows system information BGT name BG name software version memory allocation of the coupling partner and the number of channels specified in the memory of the frame coupling The displayed cycle time is the time the link is monitored on the ibaFOB SDexp side and the life counter of the frame coupling registration is incremented Registration area includes BGT...

Page 30: ...base The following fields provide essential information Current transfer duration Duration of the transfer of one sample The ratio of the Current transfer duration to the smallest Actual read cycle time gives information about the load factor of the ibaFOB SDexp card Max transfer duration Maximum duration of a data transfer since the last reset of the counters Dropped transfers Number of dropped s...

Page 31: ...s the access time and the data size Figure 22 Active data channels A double click on a row with data opens the memory view for this channel see also chapter 8 2 6 Memory view tab 8 2 5 Channels in system tab Here you ll get information about the CS 14 card and the configured communication channels You may enter as wildcard in the search string Figure 23 Channels ...

Page 32: ...y moving column headers per drag drop to the free section above Figure 24 Channels grouped by columns 8 2 6 Memory view tab The memory region 1 FPGA registers of the ibaFOB SDexp card is shown in the Memory view tab For more details please refer to chapter 8 1 3 Memory view tab ...

Page 33: ...ou plug in or unplug cards this may change the configuration of the PC This can affect the signal or I O configuration of the system because the ID of the boards may change In that case move the fiber optic cables to the correct card Always save your system configuration before changing hardware components 9 2 Procedure You should perform the following steps after you ve installed the card 1 Conne...

Page 34: ...25 C to 70 C Transport Temperature From 13 F to 158 F from 25 C to 70 C Cooling Passive Power Supply Via PCIe 1 0 x1 compatible slot Current consumption SLM Up to 950 mA FO cable Coupling 62 5 125 µm ST Lean Distance between 2 devices Up to 1 312 ft 400 m without repeater Weight incl Packaging and Documentation 0 44 lb 200 g Number of SD connections 1 duplex Data transmission rate 96 Mbit s Fastes...

Page 35: ...on per MW Max duration per MW Measuring 1 33 140 165 4 24 5 00 2 66 260 298 3 94 4 52 3 99 380 430 3 84 4 34 4 132 500 560 3 79 4 24 5 165 630 695 3 82 4 21 6 198 760 820 3 84 4 14 7 231 900 952 3 90 4 12 Overload 8 264 1030 1085 3 90 4 11 Legend Green FOB load is OK Orange FOB overload The overload range of the card is reached with 7 channels or more 224 analog values REAL and 224 digital values ...

Page 36: ...quire support specify the serial number iba S N of the product Contact Headquarters iba AG Koenigswarterstr 44 90762 Fuerth Germany Phone 49 911 97282 0 Fax 49 911 97282 33 E Mail iba iba ag com Contact Mr Harald Opel Regional and Worldwide For contact data of your regional iba office or representative please refer to our web site www iba ag com ...

Reviews: