IBA 13.114100 Manual Download Page 2

 
 

Manufacturer 

 
iba AG 

Koenigswarterstr. 44 

90762 Fuerth 

Germany 

 

Contacts 

Main office 

+49 911 97282-0 

 

Fax 

+49 911 97282-33 

 

Support 

+49 911 97282-14 

 

Engineering 

+49 911 97282-13 

 

 

E-Mail: [email protected] 

Web: www.iba-ag.com 

This manual must not be circulated or copied, or its contents utilized and disseminated, 
without our express written permission. Any breach or infringement of this provision will 
result in liability for damages. 

©iba AG 2016, All Rights Reserved 

The content of this publication has been checked for compliance with the described hard-
ware and software. Nevertheless, deviations cannot be excluded completely so that the 
full compliance is not guaranteed. However, the information in this publication is updated 
regularly. Required corrections are contained in the following regulations or can be down-
loaded on the Internet. 

The current version is available for download on our web site http://www.iba-ag.com. 

Protection note 

Windows

®

 is a label and registered trademark of the Microsoft Corporation. Other prod-

uct  and  company  names  mentioned  in  this  manual  can  be  labels  or  registered  trade-
marks of the corresponding owners. 

Certification 

The device is certified according to the European standards and directives. This device 
corresponds  to  the  general  safety  and  health  requirements.  Further  international  cus-
tomary standards and directives have been observed. 

 

 

Issue 

Date 

Revision 

Chapter / pages  

Author 

Version 
HW/FW 

1.2 

07/19/2016  New operation mode 

4.6 

 

 

 

 

 

Summary of Contents for 13.114100

Page 1: ...Data distributor ibaBM DIS i 8o Manual Issue 1 2...

Page 2: ...ll compliance is not guaranteed However the information in this publication is updated regularly Required corrections are contained in the following regulations or can be down loaded on the Internet T...

Page 3: ...8 4 2 1 Copy mode 8 4 2 2 Distribution mode 9 4 2 3 Copy and cut mode 9 4 3 Certificates 10 4 4 Device views 10 4 4 1 Front view 10 4 4 2 Top view 11 4 4 3 Bottom view 11 4 5 Indicators 12 4 6 Operat...

Page 4: ...Manual ibaBM DIS i 8o 4 Issue 1 2 8 Support and contact 21...

Page 5: ...is capable of assessing safety and recognizing possible consequences and risks on the basis of his her spe cialist training knowledge and experience and knowledge of the standard regulations 1 2 Desi...

Page 6: ...ess and the system or machine to be controlled there is a risk of death or severe injury The non observance of this safety information may result in a potential risk of death or severe injury The non...

Page 7: ...products The device must not be operated in mains supply circuits 2 2 Designated environment of use The device should only be operated and stored under conditions as described in chapter Technical da...

Page 8: ...with minimum delay and without any modifica tion All via ibaNet fiber optics transmitted signals of any ibaNet protocol type can serve as an input signal The device automatically detects the type of...

Page 9: ...ution on 8 output links by ibaBM DIS i 8o Figure 2 Principle of distribution mode 4 2 3 Copy and cut mode In copy and cut mode 1 incoming fiber optic data stream with 32 Mbit s is copied to 8 outputs...

Page 10: ...s B 4 4 Device views 4 4 1 Front view 1 2 3 4 5 6 7 8 Operating status indicators L1 L4 On off switch S11 Connector for power supply 24 V X14 Rotary switch S1 Connection FO input RX X10 Connection FO...

Page 11: ...Support iba iba ag com Internet www iba ag com Certification CE FCC Class B Power supply DC 24 V 10 0 2 A Product name ibaBM DIS i 8o Figure 4 Top view 4 4 3 Bottom view Connectors on the device botto...

Page 12: ...has been detected No 32 Mbit s signal detected L4 Red Blinking Off Error OK 4 6 Operating elements Mode of operation switch Position Mode Description 0 Copy mode All output signals input signal for al...

Page 13: ...he first 8 bytes of digital data are transmitted Input cycle time 100 s the first 128 bytes of analog data any data type and the first 8 bytes of digital data are transmitted 5 to F Reserved for futur...

Page 14: ...output Outputs iba devices with 3 3 Mbit s FO input 5 2 Application 5 2 1 Copy mode 5 2 1 1 Connecting a measurement device with 2 or more computers The measured signals from a bus module e g ibaBM DP...

Page 15: ...plied with the ibaBM DIS i 8o and serves as synchronous source for all FO links It is possible to connect more devices in a row daisy chain Figure 8 Multiplication of synchronization signals e g for i...

Page 16: ...tances the ibaBM COL 8i o can be used as a collector for up to 8 FO links 3 3 Mbit s Only 1 cable is required for the data transmission over long distance Seven FO cables can be saved On the target si...

Page 17: ...ce will immediately switch into ready for operation mode The LED L1 is blink ing During current operation you are able to perform operations on the device The device can remain switched on 6 3 Disasse...

Page 18: ...ut with 2 0 Mbit s 3 3 Mbit s 5 0 Mbit s uni direc tional 32 Mbit s mirrored to 8 1 outputs Distribution mode 1 input 32 Mbit s 1 ms sampling time with 512 digital and 512 analog signals split and dis...

Page 19: ...ing Passive Operating temperature 32 F to 122 F 0 C to 50 C Storage temperature 13 F to 149 F 25 C to 65 C Transport temperature 13 F to 149 F 25 C to 65 C Orientation Vertical typ Humidity class F no...

Page 20: ...Manual ibaBM DIS i 8o 20 Issue 1 2 7 2 Dimension sheet Dimensions given in mm Figure 11 Dimension sheet...

Page 21: ...quire support specify the serial number iba S N of the product Contact Headquarters iba AG Koenigswarterstr 44 90762 Fuerth Germany Phone 49 911 97282 0 Fax 49 911 97282 33 E Mail iba iba ag com Conta...

Reviews: