![IBA 11.112701 Manual Download Page 23](http://html1.mh-extra.com/html/iba/11-112701/11-112701_manual_604347023.webp)
ibaFOB-SDexp
Manual
Issue 1.1
23
“Analog” and “Digital” signal tables tab
In the “Analog” and “Digital” signal tables you can specify the analog and digital signals
which are received in the telegrams by the control.
Figure 12:
“Analog” tab
Name:
Here you can enter a name for the signal. Two additional comments can be defined for
each signal by clicking on the
icon.
Unit:
Here you can specify a physical unit.
Gain / Offset:
For analog values, there is the possibility of scaling the measured raw values to physical
values.
Active
Here you can select a specific captured value.
Actual:
Display of current variable raw values in numerical representation.
Other documentation
You will find a more detailed description of the columns in the general ibaPDA manual.