Indicators 

5.8.1 

Device status LEDs 

 

Run, Link and Error LEDs indicate the operational state of the ibaFOB PCI channels. 
The following table describes the states in which you may find the LEDs and their re-
spective meanings. On power on all LEDs are lit for a few seconds to prove their 
proper function. 

LED 

Status 

Indication 

Run 
(green) 

Blinking
Off 

On 

Power is on and the channel is functioning properly 
Controller stopped 

Controller stopped 

Link  
(yellow) 

On 
Off 

Telegrams received/sent on this channel 
No telegrams received; fiber optics not connected or sending de-
vice switches off  

Error  
(red) 

On 
Off 

Internal error on controller link 
Normal state; after resolution of error, LED automatically resets 

5.8.2 

7-segment display 

 

The 7-segment display shows the following information: 

 

Horizontal bar: After switching on, until the initialisation by the ibaPDA or ibaLogic 
is finished.  

 

Card-ID (ranging from 0 to 3): After card was initialized 

 

The decimal point is ON: Card is configured as an internal interrupt master  

 

The decimal point is OFF: Card is configured as an interrupt slave 

 

The decimal point is blinking: Card is configured as an external  interrupt master 

 

 

Note 

It is not allowed to configure the ibaFOB-TDC as 

external

 interrupt master. 

 

5.9 

Fiber optical interface  

The card provides 1 duplex SC type jacks with 1 optical transmitter and 1 optical re-
ceiver.  

 

 

 

Summary of Contents for 11.112600

Page 1: ...ibaFOB TDC Interface Card for SIMATIC TDC Issue 1 3 Manual...

Page 2: ...ull compliance is not guaranteed However the information in this publication is updated regularly Required corrections are contained in the following regulations or can be downloaded on the Internet T...

Page 3: ...asurement principle 10 5 6 Front view 11 5 7 Plug and socket connections 11 5 8 Indicators 12 5 8 1 Device status LEDs 12 5 8 2 7 segment display 12 5 9 Fiber optical interface 12 6 Mounting and dismo...

Page 4: ...Tab Memory view 20 9 Synchronization of more than one iba PCI card 21 9 1 Important information 21 9 2 Procedure 21 10 Technical data 22 10 1 Main data 22 10 2 Performance of the ibaFOB TDC card data...

Page 5: ...as professional if he she is capable of assessing safety and recognizing possible consequences and risks on the basis of his her spe cialist training knowledge and experience and knowledge of the sta...

Page 6: ...ion The non observance of this safety information may result in a potential risk of death or severe injury The non observance of this safety information may result in a potential risk of injury or mat...

Page 7: ...tic discharge Prior to touching any electronics card your body must be electrically discharged This can be simply done by touching a conductive grounded object immediately before hand e g bare metal c...

Page 8: ...DC ibaPDA lite SD TDC software interface Max 4 cards with up to 512 analog plus 512 digital values are supported by this software 16 telegrams with 32 analog and 32 digital values each Supports a non...

Page 9: ...TDC card acts like a SIMATIC TDC rack with a CP52A0 This topology enables the ibaFOB TDC to communicate notionally with every proces sor in one of the connected racks max 43 This would be up to more t...

Page 10: ...otection to avoid high system loads by ibaPDA The information about the variable names address book is not provided by the TDC engineering software but is transferred from the TDC CPU to the ibaPDA sy...

Page 11: ...view 1 7 segment display 2 Device status LEDs 3 FO connector SC Technik 4 FO connector SC Technik Figure 2 ibaFOB TDC card 5 7 Plug and socket connections 1 Sync connector blue Figure 3 Plug and sock...

Page 12: ...g de vice switches off Error red On Off Internal error on controller link Normal state after resolution of error LED automatically resets 5 8 2 7 segment display The 7 segment display shows the follow...

Page 13: ...advantage of the plug and play function be sure that ibaPDA V6 re spectively ibaLogic V4 has been installed before inserting the card Otherwise Win dows will not recognize the card 1 Shut down the PC...

Page 14: ...of the PC 3 Unplug the mains power line 4 Open the PC so you can reach the PCI slots 5 Release the fixing screw 6 Unplug the card carefully out of the slot Store the card in an appropriate con tainer...

Page 15: ...abled in the dongle the card should be available in the I O manager s signal tree as a data interface If you click on the interface icon in the tree you will get a simplified image of the card and ess...

Page 16: ...cators of the real card The 7 segment display shows the actual card number and the LEDs indi cate the actual status of the links The indicators on the card are described in chapter 5 8 Other documenta...

Page 17: ...processor is for support purposes only Here you can find the firmware version of the card Figure 6 Processor information 8 1 3 Tab Report control Here you ll find information about the connection and...

Page 18: ...ll find information about the command and acknowledge handshake during telegram traffic of the up to 50 PDA channels Figure 8 Command Acknowledge 8 1 5 Tab Data control Here you ll get information abo...

Page 19: ...re you find information about the GDM area where the connected TDC racks are registered Figure 10 Configuration 8 1 7 Tab Channels Here you get information about the GDM and the configured communicati...

Page 20: ...tistical log of all TDC accesses Primarily this feature has been added as a helper for the software development and optimization But you as a user may use the information as well for a better configur...

Page 21: ...unplug PCI cards this may change the PCI configuration of the PC This can affect the signal or I O configuration of the system because the ID of the cards may change In that case move the fiber optic...

Page 22: ...C to 70 C Transport Temperature From 13 F to 158 F from 25 C to 70 C Cooling Passive Power Supply Via PCI bus Current consumption 1000 mA max without connected modules FO cable Coupling 62 5 125 m SC...

Page 23: ...d efficiency without Technostring Measured efficiency with Technostring 1 2 100 100 1 3 90 50 1 4 50 50 2 4 100 100 2 5 100 100 2 6 100 100 2 7 99 55 2 8 50 50 3 8 100 100 3 10 100 100 3 11 99 50 3 12...

Page 24: ...tion between sample time and number of channels TS Technostring Reading help example At a sample time of 8 ms ibaPDA it s possible to process up to 30 channels with Techno string and 31 channels witho...

Page 25: ...pecify the serial number iba S N of the product Contact Headquarters iba AG Koenigswarterstr 44 90762 Fuerth Germany Phone 49 911 97282 0 Fax 49 911 97282 33 E Mail iba iba ag com Contact Mr Harald Op...

Reviews: