EN
TECHNICAL DATA
Minimum dynamic pressure:____________________________________________________0.5 bar
Maximum operational pressure:___________________________________________________5 bar
Recommended operational pressure:____________________________________________1-5 bar
It’s recommended to use a pressure reducer in case of
static pressure superior than 5 bar inside the waterpipe.
Maximum hot water temperature:_________________________________________________80°C
INSTALLATION, MAINTENANCE AND PRELIMINARY CHECKING PROCEDURE
In
order to get your device work correctly and fi ne in time, must ensure compliance with
the mode of installation and maintenance described in this booklet. Relying on a qualifi ed
plumber. Make sure that the system is free from all debris and impurities existing.
INSTALLATION
Fig. 1:
Insert the shower arm on the mixer body, blocking it with the grain.
Fig. 2:
Pay attention to the orientation of the fl oor plug with respect to the showerhead.
The water connection must be parallel to the showerhead.
Fig. 3 - Fig. 4:
Realize a little hole Ø90, MIN 75 mm - 2.95 in, MAX 90 mm - 3.54 in deep.
The depth refers to the fi nished fl oor, including coating.
Fig. 5:
Place the connecting body inside the hole.
Fig. 6:
Connect the pipes of the water system using PTFE or hemp to ensure a seal. Fix
the connecting body with the aid of a spirit level.
After connecting the body to the system, open the stopcocks and verify the correct tight-
ness of the connections, leaving him under pressure for few minutes.
Fig. 7:
After testing the built-in part, unscrew the plug.
Fig. 8:
Connect the ports until it locks.
Fig. 9:
Insert the pipes in the fi ttings, placing the mixer body on the fl oor.
Fig. 10:
Secure the shower column with the plugs. Place the protective housing.
Fig. 11:
Screw the showerhead to the shower arm.
After fi nishing the installation of the tap with the built-in body, turn on the stopcocks and
check that the mixer tap unit operates correctly. Keep the tap pressurized for a few minu-
tes checking eventual leaks.
CLEANING
In order to get a correct cleaning, exclusiveny wash with soap and water, rewash and dry
with deerskin and a soft cloth. Avoid to use alcohol, solvents, solid or liquid detergents
made by corrosive or acid substances, towel made by synthetic materials, abrasive spon-
ges, because they could irreversibly alterate the treated surfaces.