21. MALFUNCTION AND REMEDIES
THE UNIT DOES NOT START
POSSIBLE CAUSE
SOLUTION
AUTHORISED STAFF
Check that the unit is properly plugged
Insert the plug
User
Check that the unit is properly plugged
Insert the plug correctly
User
Check that the plug cord is broken
Replace the plug cable
Technical support
If power failure is not due to any of the above causes, call the nearest after-sales service immediately, empty the cabinet and store the foods
in coldrooms or refrigerators that may ensure their preservation temperature.
THE INTERNAL TEMPERATURE IS NOT COLD ENOUGH
POSSIBLE CAUSE
SOLUTION
AUTHORISED STAFF
Make sure that the cabinet has been filled correctly
Load the product correctly
User
Check that the unit is not adjacent to sources of heat
Position the equipment correctly
User
Check that behind the cabinet air can properly circulate.
Position the equipment correctly
User
Check that there is not too much ice on the evaporator
Defrost the equipment
User
Check the temperature setting
Set the correct temperature
Technical support
If failure to cool should is not due to any of the above reasons it it persists on even after the above checks, resort to the nearest after-sales service.
THE UNIT IS NOISY
POSSIBLE CAUSE
SOLUTION
AUTHORISED STAFF
Check that all the bolts and nuts are properly fastened
Screw in the screws
User
Check that the unit is placed on an even surface
Position the equipment correctly
User
Check if any pipe or fan is in contact with any other part of the body
Switch off the counter and distance the
parts in contact in the event the problem
persists, contact the support service.
Technical support
Should the inconvenience persist, contact the nearest after-sales service.
20. MAINTENANCE
WARNING!
Maintenance must be carried out by technical staff trained and enabled for intervention on the
flammable refrigerants.
WARNING! Any work carried out on the appliance by the user strictly requires the power plug being
disconnected from the mains socket.
ATTENTION! Use protective shoes and gloves during maintenance operations.
OPERATION
FREQUENCY
MAINTENANCE
AUTHORISED STAFF
Cleaning of external surfaces
Based on use
Ordinary
User
Cleaning of accessible internal parts (no use of tools)
Based on use
Ordinary
User
Seals intactness check
Yearly *
Ordinary
Technical support
Water collection tank cleaning
Yearly *
Ordinary
Technical support
Checking and cleaning the condenser if necessary
Yearly *
Ordinary
Technical support
Replacement components and parts
-
Extraordinary
Technical support
Any other maintenance operation not planned in the previous points should be carried out by the
support centres authorised by our dealers or by qualified staff.
* Recommended frequency for optimal counter operation and maintenance of full efficiency.