OPENING THE DROP-LEAF GLASS
To open and close the display compartment, vertically slide the drop-leaf glass on the rear of
the equipment.
Ensure perfect closure as incorrect closure would have a negative impact on the
performance of the equipment and on the excessive build-up of ice on the inner
walls.
EQUIMPENT OPEN
EQUIPMENT CLOSED
7.7
PUTTING INTO OPERATION
If the cabinet has been sharply tilted while being sited or for mounting of accessories, it
must be left to stand for at least three hours before being started to allow the lubricating
oil to settle in the compressor.
Failure to do so can cause total destruction of the compressor refrigerating system.
Check that the voltage on the identification plate is the same as that of the network.
THE ELECTRICAL SUPPLY LINE TO WHICH THE REFRIGERATOR WILL HAVE TO BE CONNECTED
IS TO BE PROTECTED BY A VERY SENSITIVE DIFFERENTIAL SWITCH (Rc=16A,Dc=30mA); IT IS
ALSO TO BE LINKED TO THE GENERAL EARTHING PLANT.
Follow the manufacturer’s instructions to install the unit, using qualified personnel and complying
with the electrical regulations for the specific country.
Incorrect installation may cause injury and damage; the manufacturer is not liable for this.
The manufacturer disclaims all responsibility for any damage to people or things due to incorrect
observance of this rule.
Earthing is necessary and compulsory by law. Absolutely never use reduction units, patch cords,
adapters or multiple socket outlets to connect the counter.
DIRECTLY connect the equipment to the mains.
The cable should be fully extended and located where it is unlikely to be struck, caught or stepped
on, away from water and the other liquids and heat sources and must not be damaged.
In case of breakage of the power cable of the cabinet, it must be replaced by the manufacturer
or by instruction it change of it.