Page 9 2019-05-10 [email protected]
J. OLED GUI manual settings
Turn the knob encoder, you can access OLED GUI manual items. Press the knob key at the highlighted item you want
to change, it will enter editing mode with item in flashing. Turn the knob encoder, you can go through all possible
settings. Press the knob key at setting you want to change to, new setting will be applied and saved. Or it will exit
editing mode if no activity for more than 3 seconds.
Item
Manual
Description
Settings
1
“Hour”
Total run time in hours. After this time,
LifePO4 power supply will turn off
automatically to protect battery form
possible over discharge
1
to 12 hours,
*Default 5 hours
Note: Setting run time will
re-start the countdown timer
at power on state
2
“Volt”
End charge voltage.
Charger will be automatically disabled into
standby mode when this voltage is reached
3.25V to 3.75V
*Default 3.35V
3
“5V”
To enable/disable the 5V linear voltage rail
EN(enabled) or DIS(disabled)
*Default is EN(enabled)
4
“Reset”
To reset all settings back to factory default
YES or NO
5
“OnSS”
Power on screen saver time in minutes
Screen will be turned off if screen save time
is up to prevent the OLED from burn-in.
DIS, or 1 to 20 minutes
*Default is DIS(disabled)
6
“OffSS”
Power off screen saver time in minutes
Screen will be turned off if screen save time
is up to prevent the OLED from burn-in.
DIS, or 1 to 20 minutes
*Default is 1 minute
7
“SCP1”
Enable or disable start up current protection
at output terminal J1.
Please keep it enabled unless need to
output very high current.
EN(enabled) or DIS(disabled)
*Default is EN(enabled)
8
“SCP2”
Enable or disable start up current protection
at output terminal J2.
Please keep it enabled unless need to
output very high current.
EN(enabled) or DIS(disabled)
*Default is EN(enabled)