It is necessary to disassemble the float chamber, and check if there is fuel inside,
remove incrustations and re-establish the proper fuel admission through the
floater-valve assembly.
TABLE SETTING CARBURETTOR OPTIMIZED FOR
COMPETITIVE USE
ENVIRONMENT
TEMPERATURE
NEEDLE
NOTCH
ATOMIZER
MAX.
JET
IDLE
JET
THROTTLE
GAS
AIR
SCREW
MIN.
20°C
K96
2 ½
(2a and
washer below)
DQ 266
162
B100-68
50
1
ROUND
e 3/4
10°C
K96
2 ½
(2a and
washer below )
DQ 267
165
B100-68
50
1
ROUND
e 3/4
2°C
K96
3
(3a and
washer above)
DQ 268
170
B100-68
50
1
ROUND
e 3/4
Rain
K28
2 ½
(2a and
washer below )
DQ 266
160
B100-68
60
1
ROUND
e 3/4
Fig. 6
Fig. 7