Power and Emergency Stop Connections

System Configuration Diagram

Note: The S1 and S2 connections correspond to the emergency stop of the Teaching Pendant.

4. LED Indicator for Power Supply

Before supplying 24V power, confirm that the PORT switch on the controller is turned OFF and that the

emergency stop circuit is not operating.

Also check to make sure that the green [RDY] and [RUN] LED indicators in front of the controller are both lit,

and that the red [ALM] indicator is not lit.

A lit [ALM] indicates that the emergency stop circuit is open, or that an alarm is occurring. At this point, you should

refer to the "Troubleshooting" section of your Operating Manual to resolve this problem.

5. Input Data & Operate with PC or Teaching Pendant

Connect the SIO connector at the front of the controller to a teaching pendant or PC. Then turn ON the PORT

switch. (If you are using a teaching pendant, first turn OFF the EMG switch. Otherwise, the emergency stop

condition will occur).

Input desired data such as position, speed, acceleration/deleceration, position range.

Note that during operation the Start Signal Input and Home Return are OFF, and Pause is ON.

PLC

Flat Cable

<CB-RCA-PIO020>

I/O Signal

Emergency stop

circuit & 24VDC

Controller

<RCP2-C>

<RCP2-CG>

Actuator

Motor Cable

<CB-RCP2-MA***>

Encoder Cable

<CB-RCP2-PA***>

PC Software

<RCB-101-MW>

Teaching Pendant,

Standard <RCA-T>

PC

External EMG Circuit

Jumper

24V

0V

Jumper

External EMG Switch

Safety

Relay

Unit

Contactor

S1

S2

MPI

MPO

24V

N

EMG

S1

S2

MPI

MPO

24V

N

FG

24V

0V

FG

- Internal Drive-Power Cutoff Relay Type <RCP2-C>

Refer to following pages

for operating instructions

- External Drive-Power Cutoff Relay Type <RCP2-CG>