Wiring 

For the controller, only the dedicated controller manufactured by our company can be used.

 

Using an undedicated controller may cause an accident such as burnout, combustion or heat generation.

 

Use the dedicated cable enclosed in the package when connecting the actuator and the controller. 

RCP4-Gripper

Dedicated connection cable
(Connect RCP4 with the dedicated controller)

Dedicated controller

• PCON-CA
• MSEP

Dedicated connection cable

Motor-encoder cable: CB-CAN-MPA□□□

*) □□□ indicates the cable length. Up to 20m can be specified.

Example) 080 = 8m

L: 5m then longer cases

L: 5m or less          

Standard cable

r = 85mm or more (Fixed use)

r = 91mm or more (Fixed use)

r = 50mm or more

 

 

[Prohibited Items in the Cable Processing] 

 

  Do not pull or bend forcibly the cable so as to give any extra load or tension to the cable. 

  Do not process the cable to extend or shortening by means of cutting out, combination or connecting 

with another cable. 

 
CB-CAN-MPA□□□, CB-CAN-MPA□□□-RB 

 

150mm

150mm

 

 

  Do not let the cable flex at a single point. 

 
 
 

 
 
 
 

  Do not let the cable bend, kink or twist. 

 
 
 
 
 
 

  Do not pull the cable with a strong force 

 

 

 

 

 

 

 

  Do not let the cable receive a turning force at a single point. 

 

 

 

 

 

 

 

 

  Do not pinch, drop a heavy object onto or cut the cable. 

 

 
 
 
 

  When fixing the cable, provide a moderate slack and do not tension it too tight. 

 

 

 

 

 

 

 

 

  Separate the I/O line, communication line and power line from each other. 

Do not store in the same duct. 

 

 

 

 

 

 

 

 

Follow the instructions below when using a cable track. 

  If there is an indication to the cable for the space factor in a cable track, refer to the wiring instruction given by the 

supplier when storing the cable in the cable track. 

  Avoid the cables to get twined or twisted in the cable track, and also to have the cables move freely and do not tie them 

up. (Arrange the wiring so the cables are not to be pulled when bent.) 

Do not pile up cables. It may cause faster abrasion of the sheaths or cable breakage. 

 
 
 
 
 
 
 

        Note: 

  When the cable is connected or disconnected, make sure to turn off the power to the controller. When the cable is 

connected or disconnected with the controller power turned ON, it might cause a malfunction of the actuator and result 
in a serious injury or damage to the machinery. 

  When the connector connection is not correct, it would be dangerous because of a malfunction of the actuator. Make 

sure to confirm that the connector is connected correctly.

 

 
 
 
 

 

Head Office: 577-1 Obane Shimizu-KU Shizuoka City Shizuoka 424-0103, Japan

TEL +81-54-364-5105  FAX +81-54-364-2589

website: www.iai-robot.co.jp/

Ober der Röth 4, D-65824 Schwalbach am Taunus, Germany

TEL 06196-88950  FAX 06196-889524

SHANGHAI JIAHUA BUSINESS CENTER A8-303, 808, Hongqiao Rd. Shanghai 200030, China

TEL 021-6448-4753  FAX 021-6448-3992

website: www.iai-robot.com

Technical Support available in USA, Europe and China

Head Office: 2690 W. 237th Street, Torrance, CA 90505

TEL (310) 891-6015  FAX (310) 891-0815

Chicago Office: 110 East State Parkway, Schaumburg, IL 60173

TEL(847) 908-1400  FAX (847) 908-1399

TEL (678) 354-9470  FAX (678) 354-9471

website: www.intelligentactuator.com

Atlanta Office: 1220 Kennestone Circle, Suite 108, Marietta, GA 30066

825 PhairojKijja Tower 12th Floor, Bangna-Trad RD., Bangna, Bangna, Bangkok 10260, Thailand

TEL +66-2-361-4458  FAX +66-2-361-4456

 

 

 

 

 

Steel Strap
(Piano Wire)

Tie them up softly.

Do not use spiral tube in any 
position where cables are bent 
frequently.

Power Line

Duct

I/O Line
(Flat Cable, etc.)

Manual No.: ME3731-2A