Chapter 3 Operation
POWER CON
PCON-CB/LC
123
[4] Tension Operation
Image diagram
No.
Position
[mm]
Velocity
[mm/s]
Accele-
ration
[G]
Decele-
ration
[G]
Pressing
[%]
Thresh-
old
[%]
Positioning
width
[mm]
Zone+
[mm]
Zone-
[mm]
Acceleration/
Deceleration
mode
Incre-
mental
Transported
load
Stop
mode
0
1 100.00 250.00 0.20 0.20
0
0
0.10
0.00
0.00
0 0
0
0
2 80.00 250.00 0.20 0.20
50
0
–50.00
0.00
0.00
0 0
0
0
3
Control method
The method of controlling the tension operation is the same as that described in [3] Pressing
operation. The control method is explained below by using the sample position table shown
above.
1) Position No.2 indicates the settings of tension operation. The settings of “Position” and
“Positioning width” show the tension start position and the tension quantity, respectively.
Attach – (negative sign) to the tension quantity. Specify the upper limit of the torque
required for tension in percent (limited current value) in “Pressing”. The speed,
acceleration, and deceleration are the conditions of positioning to the coordinate value
(80mm) set in “Position”.
2) Position No.1 indicates the tension start preparation position. Specify a value larger than
the coordinate value at which the tension provided by position No.2 ends (80 – 50 = 30mm)
in “Position”.
Position No.1
Position No.2
ST*
ST*
ST*: Start position
Tension Operation
Approach Operation
Tension Operation
Tension start position
80mm
Tension end position
80 – 50 = 30mm
Summary of Contents for PCON-CB series
Page 2: ......
Page 4: ...POWER CON PCON CB LC ...
Page 14: ...POWER CON PCON CB LC ...
Page 32: ...POWER CON PCON CB LC 18 ...
Page 84: ...Chapter 2 Wiring POWER CON PCON CB LC 70 ...
Page 174: ...Chapter 4 Field Network POWER CON PCON CB LC 160 7 EtherCAT Type 8 PROFINET IO Type ...
Page 190: ...Chapter 7 Absolute Reset and Absolute Battery POWER CON PCON CB LC 176 ...
Page 226: ...Chapter 8 Parameter POWER CON PCON CB LC 212 ...
Page 330: ...Chapter 10 Appendix POWER CON PCON CB LC 316 ...
Page 334: ......
Page 335: ......