Description 

Item 

ACON-CA/CB/CGB 

DCON-CA/CB/CGB 

Motor Control System 

Sinusoidal Waveform (AC) Drive 

Rectangular Waveform (DC) Drive 

Corresponding Encoder 

Incremental Encoder 

Serial Absolute Encoder 

Battery-less Absolute Encoder 

Incremental Encoder 

Incremental Type 

800pulse/rev 

RCA 

Serial Absolute Type  16384pulse/rev 
RCA2_*** N 

1048pulse/rev 

RCA2 

Other than 

RCA2_*** N 

800pulse/rev 

RCA 

/RCA2 

Battery-less 

Absolute Type 

16384pulse/rev 

RA1, RA4, SA1, SA4  715pulse/rev 
RA2, RA5, SA2, SA5  855pulse/rev 

RCL 

RA3, RA6, SA3, SA6  1145pulse/rev 

 

Correspon

ding   

Encoder 

Resolution 

RCD 

 

 

400pulse/rev 

Actuator Cable Length 

MAX. 20m 

MAX. 10m 

Serial Communication Interface 

(SIO Port) 

RS485  : 1 CH (based on Modbus Protocol RTU/ASCII) 

Speed  : 9.6 to 230.4Kbps 

Control available with serial communication in the modes other than the pulse train 

PIO Type 

Signal I/O dedicated for 24V DC (selected from NPN/PNP) … Input 16 points max., 

output 16 points max. Cable length    MAX. 10m 

External Interface 

Field Network Type  DeviceNet, CC-Link, PROFIBUS-DP, CompoNet, MECHATROLINK-

/

EtherCAT, EtherNet/IP, PROFINET-IO, MECHATROLINK-

*, CC-Link IE*   

(* Some types cannot connect it.) 

Data Setting and Input 

PC Software, Touch Panel Teaching, Teaching Pendant, Data Setter 

Data Retention Memory 

Saves position data and parameters to non-volatile memory   

(There is no limitation to the number of times data may be written.) 

Operation Mode 

Positioner Mode/Pulse Train Control Mode (selected by parameter setting) 

Number of Positions in Positioner Mode  Standard 64 points, MAX. 512 points (PIO Type) 

(Note)  Number of positions differs depending on the selection in PIO pattern. 
Differential System (Line Driver System) : MAX. 200kpps 

Cable length    MAX. 10m 

Input Pulse Frequency 

Open Collector System : Not applicable. 

* If the host applies the open collector output, prepare AK-04 (option) separately to 

convert to the differential type. 

Command Pulse Multiplying 

Factor (Electrical Gear : A/B) 

1/50 

A/B 

<

 50/1 

Setting Range of A and B (set to parameter) : 1 to 4096 

Pulse 

Train 

Interface 

(Note4)

 

Feedback Pulse Output 

None 

LED Display (mounted on Front Panel)  SV (GN)/ALM (RD)  :  Servo ON/Alarm generated 

STS0 to 3 

:  Status display 

RDY (GN)/ALM (RD)  :  Absolute function in normal / absolute function error (for the 

simple absolute type) 

1, 0 (GN) (RD) 

:  Absolute function status display (for the simple absolute type) 

Electromagnetic Brake Compulsory 

Release Switch (mounted on Front Panel) 

Switching NOM (standard)/BK RLS (compulsory release) 

Insulation Resistance 

500V DC    10M

Ω

 or more 

Protection Function against Electric Shock  Class I basic insulation 

Incremental Type 

Screw fixed type : 230g or less    DIN rail fixed type : 265g or less 

Simple Absolute Type 

Battery (AB-7) : 190g or less 

Absolute Battery Case (SEP-ABU) : 

140g or less 

 

 

Weight 

(Note3) 

(Other 

than Field 

Network 

Type) 

Serial Absolute Type 

Battery (AB-5) : 20g 

 

Cooling Method 

Natural air-cooling

 

External dimensions 

Screw fixed type : 35W×178.5H×69.6D 

DIN rail fixed type : 35W×185H×78.1D 

Surrounding Air Temperature  0 to 40

°

Surrounding Humidity 

85%RH or less (non-condensing) 

Surrounding Environment 

[Refer to Installation Environment] 

Surrounding Storage 

Temperature 

-20 to 70

°

C (Excluding battery) 

Usage Altitude 

1000m or less 

Protection Class 

IP20 

Environment 

Vibration Durability 

Frequency 10 to 57Hz / Swing width : 0.075mm 

Frequency 57 to 150Hz / Acceleration 9.8m/s

2

 

XYZ directions    Sweep time : 10 minutes    Number of sweep : 10 times 

 

Note1  Control power capacity is 0.3A. 
Note2  In-rush current will flow for approximately 5msec after the power is turned on (at 40

°

C). 

Note that the value of in-rush current differs depending on the impedance of the power supply line. 

Note3  Add the weight of the battery (case) for “Simple Absolute Type” and “Serial Absolute Type”. 
Note4  Serial absolute type is not applicable for the pulse train control mode. 
Note5  The current reaches the maximum at the excitation phase detection of the motor conducted when the servo is turned 

on for the first time after the power is supplied. (TYP 1 to 2 second, MAX. 10 second) 

 

External Dimensions (ACON, DCON, PCON-CA/CB/CGB) 

* There is only Incremental Type in DCON. 

●  Screw fixed type

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

●  DIN rail fixed type

 

35

178.5

185

M3

M3

35

178.5

185

M3

35

178.5

185

8.5

4

(5)

(58)

(5)

(5)

(52)

78.1

Simplified Absolute Type

(Option)

Serial Absolute Type

(Option)

Side View

Battery-less Absolute/

Incremental Type

104  from DIN rail center

35.4 (Width of 35mm DIN rail)

(for FG cable
 attachment)

(for FG cable
 attachment)

(for FG cable
 attachment)

 

 

 

 

 

External Dimensions (PCON-CFA/CFB/CGFB) 

●  Screw fixed type 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

●  DIN rail fixed   
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Installation Environment 

This product is capable for use in the environment of pollution degree 2

*1

 or equivalent. 

*1  Pollution Degree 2: Environment that may cause non-conductive pollution or transient conductive 

pollution by frost (IEC60664-1) 

1. Installation Environment 

Do not use this product in the following environment 

  Location where the surrounding air temperature exceeds the range of 0 to 40

°

  Location where condensation occurs due to abrupt temperature changes 

  Location where relative humidity exceeds 85%RH 

  Location exposed to corrosive gases or combustible gases 

  Location exposed to significant amount of dust, salt or iron powder 

  Location subject to direct vibration or impact 

  Location exposed to direct sunlight 

  Location where the product may come in contact with water, oil or chemical droplets 

  Environment that blocks the air vent [Refer to Installation and Noise Elimination] 

When using the product in any of the locations specified below, provide a sufficient shield. 

  Location subject to electrostatic noise 

  Location where high electrical or magnetic field is present 

  Location with the mains or power lines passing nearby 

2. Storage and Preservation Environment 

  Storage and preservation environment follows the installation environment. Especially in a long-term storage, consider 

to avoid condensation of surrounding air. 
Unless specially specified, moisture absorbency protection is not included in the package when the machine is 
delivered. In the case that the machine is to be preserved in an environment where dew condensation is anticipated, 
take the condensation preventive measures from outside of the entire package, or directly after opening the package. 

Installation and Noise Elimination 

1.  Noise Elimination Grounding (Frame Ground) 

 
 

 
 
 
 
 
 
 
 
 

2.  Precautions regarding wiring method 

1)  Wire is to be twisted for the 24V DC power supply. 

2)  Separate the signal and encoder lines from the power 

supply and power lines. 

3.  Noise Sources and Elimination 

Carry out noise elimination measures for power devices on 

the same power path and in the same equipment. 

The following are examples of measures to eliminate noise 

sources. 

1)  AC solenoid valves, magnet switches and relays 

[Measure] Install a Surge absorber parallel with the coil. 

2)  DC solenoid valves, magnet switches and relays 

[Measure] Install a diode parallel with the coil. Use a DC 

relay with a built-in diode. 

4.  Heat Radiation and Installation 

Design and Build the system considering the size of the 

controller box, location of the controller and cooling factors to keep the surrounding temperature around 

the controller below 40

°

C. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Connection Diagram 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
● Connection to RCP2 (High-Thrust), RCA and RCL Series 

 
 
 
 
 
 

●  Connection to RCP3, RCP4, RCP5, RCP6 and RCA2 Series 

 
 
 
 
 

Surge absorber

Relay 
coil

Relay coil

R

C

+24V

0V

+24V

0V

+

-

MIN.
30mm

MIN.
30mm

MIN.
30mm

MIN.
30mm

MIN. 100mm

MIN. 50mm

MIN. 100mm

Ensure enough space 
for wiring.

(Note1) 

Detach the fan unit before 
attaching screws to the 
main unit. 

PCON
ACON

Motor/
Encoder Connector

Connection 
Cable

(Note1)

Connection 
Cable

(Note1)

PCON
ACON

Motor/
Encoder Connector

Do not share the ground wire with or connect 
to other equipment. Ground each controller.

Controller

Other 

equipment

Controller

Other 

equipment

Other 

equipment

 

Connect the ground cable 
using the tapped hole for 
FG connection on the main unit.

M3 × 5 nickeled pan head 
machine screw
(enclosure dedicated for 
DIN rail fixed type)

Screw fixed type

DIN rail fixed type

Connect the ground line 
together to the main unit 
using the fixing screw.

Copper wire:
Connect a ground wire with a 
diameter of 1.6mm (2mm

2

) or larger.

Earth Terminal
Grounding resistance 100Ω or less
(Class D grounding)

Teaching Pendant (Option)

PC Software (Option)

Personal 
Computer

Actuator

Brake Release Switch

Host System <PLC>

Axis No. Setting Switch

Operation Mode 
Setting Switch

35

(7)

170.5

190

5

69.6

φ

(Note1)

35

(7)

190

(5)

78.1

8.5

4

196.5

115  from DIN rail center

35.4 (Width of 35mm DIN rail)

35

φ

5

170.5

178.5

5

35

φ

5

5

(40.5)

(58)

170.5

178.5

35

φ

5

5

(34.5)

(52)

170.5

178.5

69.6

Simplified Absolute Type

(Option)

Serial Absolute Type

(Option)

Side View

Battery-less Absolute/

Incremental Type