123
9.
ASEL, PSEL
and SSEL
No.
Parameter name
Factory
setting Input range
Remarks
122
10
H
Bits 0 to 11:
"PC/TP Reconnection Latency at Software
Reset" added time (sec) when fieldbus in use
* Valid Values from 0 to 500 (sec)
(ASEL/PSEL: Main application of Ver.0.36 or later
SSEL: Main application of Ver.0.42 or later)
225 Network I/F module control
2
H
Read only
Bits 0 to 3: Network I/F module type
(0: Not installed, 1: CC-Link module, 2:
DeviceNet module)
226 Network I/F module –
Network Attribute 3
Communication attribute 1
0
0~999
Node address of the network I/F module
* DeviceNet module: 0 to 63
227 Network I/F module –
Communication attribute 2
0
H
0
H
~
FFFFFFFF
H
0
H
~
FFFFFFFF
H
Bits 0 to 3: Baud rate type of the network
I/F module
* With the DeviceNet module, the baud
rate is automatically set to the same
value as the baud rate set in the
master. Accordingly, you need not set
the baud rate.