the value of the dose accumulated since the last switching on or the total summarized value for 
all the periods of working according to your choice made by the push-buttons 

«˄» 

or

 «˅».  

 
Note.  The  human  body  accumulates  the  radiation  dose  that’s  why  while  staying  at  the 

locations  with  the  elevated  levels  of  radiation  for  a  long  time  it’s  necessary  to  summarize  the 
continuous  readings  taken  from  an  individual  detector.  The  Radiation  meter  EcoLife  Pro1 
automatically summarizes the accumulated dose from the moment of switching on and for all the 
periods  of  working.  3  millisieverts
  per  hour  is  the  normal  annual  background  radiation  dose 
considered safe. During the life the accumulated dose value must be below 100-700 millisieverts 
summarized (according to the local radiation background). 

 
1.4.4. Control buttons are used to: 
 

- switch the device on and off; 

- switch to the Option menu; 

- navigate through the Option menu and choose the values; 

- switch to the Measurement mode; 

- switch the screen off when the device in work (Power economy mode). 

 
1.4.5. The power supply is carried out by two AAA batteries or by the accumulators of the 

same  type.  How  to  install  batteries  into  the  case  you  can  see  on  the  battery 
compartment’

s

 bottom or at the Figure 4. 

 

Fig. 4 –Batteries installation scheme 

 
 

2.  Correct use 
 
2.1 Use Limits 
 

2.1.1. Keep the battery compartment and the power supply contacts clean.  
2.1.2. Timely change the discharged batteries or charge the accumulators.   

Summary of Contents for 62252

Page 1: ...Package and transportation 6 Proof of acceptance 7 Manufacturer s warranty 8 Certification information Warranty Card Appendix General information of the radiation nature and the material radiation in...

Page 2: ...ifferent readings This situation is similar to the rain in everyday life When there is a bit of rain it s difficult to detect how many drops drip per second by hand there may be 2 drops more or no one...

Page 3: ...accumulated dose selecting the unit measures roentgen Sievert setting and changing the alarm sound of the ambient dose rate threshold audiovisual warning of the ambient dose rate threshold excess sett...

Page 4: ...re than 105 58 18 5 Mass with batteries grams not more than 110 1 3 Contents of the box 1 3 1 The table below gives the information about parts of the product and the delivery set Table 2 Name number...

Page 5: ...nging from 10 to 80 seconds depending on the radiation rate The displayed values are automatically changing and being averaged by the microprocessor This averaging process is displayed by the measurem...

Page 6: ...iation dose considered safe During the life the accumulated dose value must be below 100 700 millisieverts summarized according to the local radiation background 1 4 4 Control buttons are used to swit...

Page 7: ...edure To prepare the product for working you should loosen the screw and remove the battery compartment cover no 3 Fig 2 install the batteries respecting polarities Fig 4 place back the battery compar...

Page 8: ...button come back to the Measurement settings menu Fig 8 for further settings 2 3 1 4 Setting the threshold of the ambient dose rate above which the device sounds because the radiation level is high wh...

Page 9: ...opposite the chosen brightness and the screen brightness will be changed according to your choice by pushing the button come back to the Screen settings menu fig 9 for further settings 2 3 1 8 Setting...

Page 10: ...hing the buttons choose the line BUTTONS SOUND and confirm your choice by pushing the button or by pushing the buttons and choose the value ON or OFF to switch the buttons sound on and off and confirm...

Page 11: ...rgy of the batteries when user forgets to switch off the device For settings you should when you are in the Main menu 7 by pushing the buttons choose the line SETTTINGS and confirm your choice by push...

Page 12: ...e the line SETTTINGS and confirm your choice by pushing the button or in the opened submenu by pushing the buttons and choose the line ACCUMULATOR and confirm your choice by pushing the button or by p...

Page 13: ...dio signal passing frequency occur At the same time the ambient dose value is raising in the upper right corner of the screen and the columns at the radiation environment time based historical graphs...

Page 14: ...e the natural radiation background normal for the location it indicates that the object you investigate is polluted by radiation To define the ionization radiation source you should remove the working...

Page 15: ...pair should be carried out by the dealer 5 Package and transportation Every Product delivery set see Table 2 is packaged in individual corrugated fiberboard box The moving of contents of the box is no...

Page 16: ...or the authorized Distributor shall replace or repair the products broken down during the guaranteed use period at the expense of them 7 5 This warranty shall be void if guaranteed use period is over...

Page 17: ..._________________________________________________________________________ Sale Date _________________________________________________________________________ Vendor s stamp and signature _____________...

Page 18: ...es caused to biological tissues by ionizing radiation exposure depend on the dose of absorbed radiation energy To characterize it the term absorbed dose is used i e the energy absorbed by the unit of...

Page 19: ...The equivalent dose rate H is defined by the formula H dH dT where dT is a period of time In the SI system the equivalent dose rate H is measured by Sievert per second Sv s 1 Sv s 100 Rem s 1 Sv s R s...

Reviews: