49
i3PROJECTOR
manual 3303W UM
Appendices
Installation
49
Apendices
The screws on
the latern and the
lamp shall not be
removed.
If the lamp cover
is not reinstalled
on the projector
yet, the projector
cannot be switched
on.
Do not touch the
glass area of the
lamp. Oil on hands
may cause the
lamp to break up.
If you accidentally
touch the lamp
module, please
clean it with dry
cloth.
Cleaning procedure for air filter:
1. Press “ ” button to power off the projector.
2. Cool down the projector for at least 30 minutes.
3. Pull off the power cable.
4. Press the release button, and pull up the lamp cover of the main compo-
nents. 1
5. Lift up and remove the lamp cover. 2
6. Remove the 2 screws on the lamp module. 3
7. Pull up the Lamp Handle 4, and pull out the lamp module carefully and
slowly. 5
Follow the aforesaid steps in the reverse order to install the lamp module.
8. After the lamp module is replaced, switch on the projector and reset the
lamp hour counter.
To reset the lamp, please finish the following steps:
(i) Press
to open the
“Service”
menu.
(ii) Select
“Reset Lamp Hours”.
(iii) Press “OK” to confirm the selection.
1
2
3
4
5