Page -3-

Am53 Analog Dome Camera

CALLING UP OSD via VIDEO PILOT CLIENT (incl. SRX-PRO 

SERVER v7 and up).

1. 

Repeat Steps 1-5 of the

 ADJUST ZOOM/FOCUS via VIDEO PILOT CLIENT (incl. 

SRX-PRO SERVER v7 and up) section.

2. 

Use the 

Iris Open

 in the PTZ Advanced Options side panel and the on-screen 

UP/DOWN/LEFT/RIGHT

 buttons to bring up and navigate in the OSD menus.

CALLING UP OSD via VEO16p (LOCAL) 

1. 

Repeat Steps 1-5 of the 

ADJUST 

ZOOM/FOCUS via VEO16p 

(LOCAL) section.

2. 

Use the 

Iris Open

 icon and the 

UP/DOWN/LEFT/RIGHT

 buttons 

on the PTZ panel to bring up and 

navigate in the OSD menus.

CALLING UP OSD via VEO16p (REMOTE) 

1. 

Repeat Steps 1-7 of the 

ADJUST ZOOM/

FOCUS via VEO16p (REMOTE) section.

2. 

Use the 

Iris Open

 icon and the 

UP/

DOWN/LEFT/RIGHT

 buttons on the PTZ 

panel to bring up and navigate in the OSD 

menus.

CAMERA OSD MENU

ADJUST ZOOM/FOCUS via VIDEO PILOT CLIENT 

(incl. SRX-PRO SERVER v7 and up)

1. 

Repeat Steps 1-5 of the

 ADJUST ZOOM/FOCUS via SRX-PRO 

SERVER v6 and lower section OR Steps 1-3 of the ADDING 

HR16 to SRX-PRO v7 depending on the SRX-Pro Server version.

2. 

Add the SRX-Pro Server to CONTROL tab of the Video Pilot 

Client if connecting from a remote location, or use 

localhost

 

connection, automatically generated by VPC.

3. 

Connect to the remote SRX-Pro Server with VPC.

4. 

Double-click on the Am53 camera to bring it into full single-

channel division.

5. 

Click 

PTZ > Advanced 

in the on-screen menu.

6. 

Use the on-screen Zoom In/Out controls and 

Focus In/Out controls in the PTZ Advanced Options side panel to adjust Zoom and 

Focus until the desired view is achieved.

ADJUST ZOOM/FOCUS via VEO16p (LOCAL)

1. 

Connect Am53 to Veo16p BNC output.

2. 

Log into your Veo16p (Default: ADMIN/1234).

3. 

Go to 

MENU > SYSTEM SETUP > CAMERA > PTZ 

SETUP

4. 

In PROTOCOL drop down menu, select 

COAXITRON

 for 

all Am53 cameras. Click 

APPLY

, then 

CLOSE

.

5. 

On the Veo16p Live screen, click the PTZ button to 

display PTZ control panel.

6. 

Use the ZOOM and FOCUS icons adjust Zoom and Focus 

until the desired view is achieved.

ADJUST ZOOM/FOCUS via VEO16p (REMOTE)

1. 

Repeat Steps 1-4 of the

 ADJUST ZOOM/FOCUS via VEO16p 

(LOCAL) section.

2. 

Connect your Veo16p to the network using the ETHERNET 

port on the rear panel. Follow Veo16p manual for more 

instructions.

3. 

On the remote PC, open Internet Explorer and enter the IP 

address of your Veo16p in the address bar, followed by the 

Web Service Port. Default service port: 

8080

(E.g. 

http://192.168.0.59:8080

)

4. 

Enter user credentials in the login screen. 

(Default: ADMIN/1234).

5. 

Install ActiveX, as required.

6. 

In the Veo16p Live screen mode, double-click on the Am53 

camera to bring it into full single-channel division.

7. 

Click on the PTZ tab and use Use the ZOOM and FOCUS icons adjust Zoom and Focus 

until the desired view is achieved.

CALLING UP OSD MENU

Camera’s OSD menu can be accessed through i3’s encoder, i3’s standalone HVR’s local or 

remote interfaces or through SRX-Pro/VPC interface.

In all cases, 

Iris Open

 icon in the Live Mode PTZ panel will 

bring up the camera’s on screen display.

PTZ panel OSD Menu control buttons:

Iris Open

 - Bring up the OSD, confirm menu selection/enter 

sub-menu.

UP/DOWN arrows 

to navigate within camera menus.

LEFT/RIGHT arrows

 to adjust value of the selected item.

CALLING UP OSD via HR16

1. 

Repeat Steps 1-8 of the 

ADJUST ZOOM/FOCUS via HR16 

section.

2. 

Use the 

Iris Open

 and 

UP/DOWN/LEFT/RIGHT

 buttons 

on the PTZ Control panel to bring up and navigate in the 

OSD menus.

CALLING UP OSD via SRX-PRO SERVER v6 

and lower

1. 

Repeat Steps 1-8 of the

 ADJUST ZOOM/FOCUS via SRX-

PRO SERVER v6 and lower section.

2. 

Use the 

Iris Open

 and 

UP/DOWN/LEFT/RIGHT

 buttons 

on the Advanced Control panel to bring up and navigate in the OSD menus.

MAIN MENU

CONTRAST

BACK

IMAGE MODE

EXPOSURE MODE

EXIT

WHITE BALANCE

AGC

BRIGHTNESS

BACK

FACTORY DEFAULT

DAY/NIGHT

VIDEO SETTINGS

EXPOSURE

3DNR

EXIT

SHARPNESS

SATURATION

EXIT

SAVE & EXIT

MODE

VIDEO FOR

MAT

SAVE & EXIT

SAVE & EXIT

MIRROR

BACK

EXIT

SAVE & EXIT

Summary of Contents for Am53

Page 1: ...ervice monitor Four 4 video formats supported HD TVI default HD AHD HD CVI and CVBS Use the video format switch 2 to set video format as required 6 Power connector DC12V AC24V 7 Video format switch Default video format setting HD TVI DISASSEMBLY AND INSTALLATION To prepare the camera for mounting remove the camera s dome bubble by unscrewing three screws using the Security torx bit provided Do not...

Page 2: ...g and tilting the camera lens assembly and rotating the camera lens base Do not over rotate beyond the stop point to avoid damage to the camera 9 Adjust the camera s zoom and focus through a DVR HVR encoder SRX Pro VPC software or HD service monitor with BNC input See LENS ADJUSTMENT section for more information 10 Adjust any additional camera settings e g image brightness color or contrast day ni...

Page 3: ...ick the PTZ button to display PTZ control panel 6 Use the ZOOM and FOCUS icons adjust Zoom and Focus until the desired view is achieved ADJUST ZOOM FOCUS via VEO16p REMOTE 1 Repeat Steps 1 4 of the ADJUST ZOOM FOCUS via VEO16p LOCAL section 2 Connect your Veo16p to the network using the ETHERNET port on the rear panel Follow Veo16p manual for more instructions 3 On the remote PC open Internet Expl...

Page 4: ...e value the sooner the camera will switch from day Color mode to night B W mode as the scene becomes darker N D THRESHOLD available in the AUTO mode only Set the value from 0 lowest to 9 highest The higher the value the sooner the camera will switch from night B W mode to day Color mode as the scene becomes lighter MAIN MENU VIDEO SETTINGS VIDEO SETTINGS setup contains settings for IMAGE MODE WHIT...

Reviews: