background image

CONFIGURING DOOR COUNT IN SRX-PRO

Before configuring Door Count feature, connect Ax47DC to SRX-Pro 

by following instructions in the side panel on the right.

1. 

In SRX-Pro Server, click the Setup button and go to the VisionCount tab.

2. 

Select the Ax47DC camera in the Channel Selection menu.

3. 

Select 

DoorCount

 in the Analytic Type menu.

4. 

Check the 

Enable

 check box.

5. 

Click the DoorCount drawing tool and 

position your cursor over the one end 

of the entrance door in the preview window.

6. 

Left-click and drag the mouse cursor to draw the green line in front of the door 

entrance. Release the mouse cursor. A three-segment red door count line will be 

drawn on the preview window

Note: 

If the count line is 

up-side-down, click the Flip tool.

The DoorCount line consists of 3 line 

segments that act as a “funnel” for 

foot traffic entering the premises. Door 

Count camera installation must meet all 

requirements listed in the installation 

section. Use the sample pictures as a 

guide for the correct installation and the correct Door Count line drawing. 

7. 

Enter 

Door Name

 (optional) for your DoorCount 

line. If you have more than one Door Counting 

camera it may be useful to assign each with 

unique name for ease of identification.

8. 

Select 

In

Out

 or 

In & Out

 in Display Live menu 

to display counting data for foot traffic entring, 

exiting or both.

9. 

Configure 

Active Time

 (optional). You may use Active Time setting to count the 

customers entering during a specific shift only, for example. Otherwise use the default 

Active Time value to count all foot traffic.

10. 

Click the 

Save

 button in the bottom right corner of the screen.

 

Ax47DC Door Counting Dome Camera

QUICK START GUIDE

INSTALLATION

1. 

For accurate count, Ax47DC installation must comply with all requirements below:

a)  Mounting height

 between 2.43m (8’) and 3.65m (12’) Above Finished Floor (AFF). 

Reliability decreases outside of this range.

b)  Centered

 on doorway and 1.22m (4’) in from the doorway.

CONNECT CAMERA TO i3 SRX-PRO SERVER

Camera’s default IP address: 

192.0.0.16

.

Camera’s default Subnet mask address: 

255.255.255.0

.

Login: 

i3admin

 / Password: 

i3admin

Change your Annexxus camera’s default IP Address:

1. 

Close SRX-Pro Server software by pressing 

Alt+Shift+Ctrl+F4

.

2. 

Change the IP address of the onboard NIC (LAN) of your SRX-Pro Server (or of 

NIC1 if your SRX-Pro Server has two onboard NIC cards) to 192.0.0.XXX to match 

the default IP range of your Annexxus IP camera.

3. 

Connect your Annexxus camera to i3 SRX-Pro Server (see diagram above).

4. 

Restart SRX-Pro Server software. Log in and go to the 

Setup

 -> 

IP Camera 

tab.

5. 

Click 

ACT Config Tool

 icon. If your NVR does not have 

Annexxus Configuration Tool, download and install it from 

http://i3international.com/software-downloads

 website.

6. 

In ANNEXXUS Configuration Tool window, a list of active network cameras will be 

displayed. Select your desired camera in the list.

7. 

Enter the new IP address and Subnet Mask of the camera in the Device(s) 

Communication Update area and click 

Update

. The new camera IP address must 

match the 

original range of your SRX-Pro LAN or NIC1 card. E.g. If your original 

SRX-Pro Server’s IP address was 192.138.10.122, change your Annexxus 

camera’s IP address to 192.138.10.XXX. 

Remember: Annexxus Cameras cannot share an IP address, each camera 

requires its own unique IP address. 

8. 

Wait a few moments for a “Success” message in the Result field.

9. 

Repeat Steps 7-9 for all detected Annexxus cameras in the ACT.

10. 

Change the IP address of the NIC back to its original setting (reverse Step 2).

Ensure you can connect to your camera using its new IP Address:

1. 

Open an Internet browser window and enter the new IP Address you have just 

assigned to your Annexxus camera in Step 7.

2. 

Enter the default camera User Name and default Password in the pop-up login 

window.

3. 

Annexxus camera interface will be displayed in the Internet Explorer window. 

You should be able to see the camera image on the screen. 

If you do not see the camera image on the screen, call i3 International technical 

support team for troubleshooting tips: 1.877.877.7241

Add your Annexxus camera to IP Camera tab in SRX-Pro Server:

1. 

Ensure that the latest version of GiPi updater is installed on your SRX-Pro Server. 

Latest GiPi available from 

http://i3international.com/software-downloads

Note: SRX-Pro must be closed while GiPi updater is installed. After GiPi updater 

installation, start i3 SRX-Pro Server software again.

2. 

Log In and go to the 

Setup

 -> 

IP Camera 

tab.

3. 

Click the 

Search & Add

 button to display connected Annexxus cameras.

4. 

Select the detected camera in the list and click 

Select

.

5. 

In the 

Select IP Camera window, enter the default camera User Name and 

Password, then click 

Add

. Selected camera will be added to the IP Camera list.

6. 

Assign the IP camera to the SRX-Pro video channel in the 

Ch In. 

column.

Your Annexxus camera is now connected to SRX-Pro Server and is ready to record. 

You may change resolution and frame rate for the Annexxus camera in the IP Camera 

tab menu or you may choose to configure the camera’s settings via Web Setup.

i3 SRX-Pro Server

LAN

i3 SRX-Pro Server

Via Gigabit Switch

Connection Type 1:

Connection Type 2:

the counting results.

2. 

Prepare the surface for mounting. Use supplied guide 

pattern sticker to drill screw holes on the mounting 

surface. Insert plastic anchors. If routing cables from 

the back of the camera, cut a cable hole in the surface. 

Alternatively, cables can be routed through the opening 

on the side of the camera’s mounting base.

3. 

Disassemble camera prior to mounting. Loosen three 

screws on the camera with the supplied Torx key to 

remove the Bubble Dome Cover.

4. 

Attach the camera’s mounting base to the surface with 

supplied screws.

5. 

For best door counting accuracy set the camera’s tilt 

position straight down. Adjust the camera’s pan position 

to achieve required Field of View (see requirement 1c).

6. 

Replace the Bubble Dome Cover and use the Torx key to 

re-tighten the screws.

c)  Field of View 

must be adjusted so that the 

camera views through the doorway with the 

top of the image aligned between the top of 

the doorway and half-way down to the bottom 

of the doorway. Do not cut off more than the 
top half of the 

doorway. The 

width of the 

image should be 

about 2 to 2½ 

times the width 

of the doorway. 

Sharp focus is 

essential. Hanging 

signs, banners, 

balloons, etc., in 

the field of view 

will interfere with 

Doorway (Side View)

Ax47DC Camera (Side View)

Finished Floor

Centered 

on and 

1.2m 

(4 ft)

 

from the 

doorway

min.
 

2.43 m (8 ft)

 AFF

max.

 3.65 m (12ft)

 AFF

Doorway (Top View)

Ax47DC Camera (Top View)

Centered 

on and 

1.2m 

(4 ft)

 

from the 

doorway

Door

SAMPLE DOOR COUNT INSTALLATIONS

CANADA

 

780 Birchmount Road,

 

Unit 16, Toronto,

 

ON, M1K 5H4

U.S.A

 

4450 Witmer Industrial Estates     

 

Unit 4 Niagara Falls,

 

NY 14305

www.i3international.com

1.866.840.0004