![I.VA.CO. SC Series Operating And Maintenance Manual Download Page 5](http://html1.mh-extra.com/html/i-va-co/sc-series/sc-series_operating-and-maintenance-manual_603485005.webp)
I.VA.CO. Srl
5
Ed.12/2016
Improper use of
SC
blowers and exhausters can cause serious injuries.
Danger is due to:
-
Suction: side channel blowers and exhausters have a very high suction power. Objects, clothing
and hair can be easily sucked into the fan and cause injuries.
-
Discharge side: there is a very powerful stream of air from the discharge side. Foreign objects,
which might have been sucked into the fan, can be expelled at high speed and cause injuries.
-
Temperature: when the machine operates the temperature of the housing can exceed 100°C. The
machine has to be protected from any contact in order to avoid burns.
-
Rotating parts
-
Over-pressure and vacuum
-
Motor fan
-
Defective or missing silencers
In case of failure, check that all protection and safety devices are functioning and activated, disconnect the
electric power supply and inform the plat personnel responsible for operation.
6.
TRANSPORT
SC
blowers and exhausters must be transported by adequate equipment suitable to their weight and
packing dimensions and in accordance with the safety standard on force. When transporting, installing and
performing maintenance, it is important to grant a safe lifting of the machine; using serviceable lifting slings
installed and operated by skillful personnel. Any eye bolt or lifting point designed for single part of the
machine shall not be used to lift the complete machine.
7.
STORAGE
All
SC
blowers and exhausters are dispatched with the main connections (like suction and discharge
nozzles), closed by plastic plugs or adhesive disks.
Handle the packing with care avoiding shocks.
Avoid to place heavy loads on top of the boxes.
If the machine has to be stored for a long period (several months) it is advisable to put it back into its
original packaging, which should be accurately closed and stored in a dry, protected and clean area.