I.VA.CO. SC Series Operating And Maintenance Manual Download Page 1

 
 
 
 

 

 

OPERATING AND MAINTENANCE MANUAL 

 

SIDE CHANNEL 

BLOWERS AND EXHAUSTERS 

SC Series 

 

SC101MF 

-

  SC201MF 

-

  SC301MF 

-

  SC401MF 

-

  SC431MF 

-

  SC501MF 

-

  SC531MF 

SC601MF 

-

  SC631MF 

-

  SC602PF 

-

  SC701MF 

-

  SC731MF 

-

  SC802PF 

-

  SC901MF 

-

 

SC931MF 

-

 SC942PF 

-

 SC951MF 

-

 SC302SF 

-

 SC402SF 

-

 SC502SF 

-

 SC602SF 

-

 SC902SF 

SC902PF

 

 

 

 

ORIGINAL INSTRUCTIONS 

English 

 

I.VA.CO. Srl

 

Via delle Brigole, 33 – 23877 Paderno d’Adda (LC) – Italy

 

www.ivaco.it

 – 

[email protected]

 

-

 +39 039 9281084

 

 

Summary of Contents for SC Series

Page 1: ...01MF SC401MF SC431MF SC501MF SC531MF SC601MF SC631MF SC602PF SC701MF SC731MF SC802PF SC901MF SC931MF SC942PF SC951MF SC302SF SC402SF SC502SF SC602SF SC902SF SC902PF ORIGINAL INSTRUCTIONS English I VA CO Srl Via delle Brigole 33 23877 Paderno d Adda LC Italy www ivaco it info ivaco it 39 039 9281084 ...

Page 2: ...AL CONNECTIONS DRAWINGS 12 4 ACCESSORIES INSTALLATION DRAWING 13 START UP ADJUSTMENT 14 MAINTENANCE 14 1 CLEANING 14 1 1 SILENCER ELEMENTS REPLACEMENT 14 2 SEALING RINGS AND BEARINGS REPLACEMENT 15 OPERATING PROBLEMS AND TROUBLE SHOOTING 16 SHUT DOWN PERIOD 17 MACHINE SCRAP AND DISPOSAL 18 REPAIR 19 SPARE PARTS ATTACHMENTS EXPLODED ASSEMBLY DRAWINGS WITH PARTS LIST EU DECLARATION KLIXSON SPECIFICA...

Page 3: ...MENTS When receiving the goods it is necessary to inspect and check them against the shipping documents Make sure that no shipping damages are occurred to the equipment during transportation Accessories come loose and have to be mounted before start up 3 WARRANTY The goods related with this instruction manual are free from defects in materials and workmanship The warranty period is twelve months f...

Page 4: ...epresentative the warranty wiII become void and unenforceable and I VA CO SRL shall not be liable for any damage to anything or anybody that could happen after any unauthorized operation or replacement I VA CO SRL shall not be liable for any damage directly or indirectly arising in connection with the machine non use during the repair under guarantee I VA CO SRL shall not be liable for any damage ...

Page 5: ... power supply and inform the plat personnel responsible for operation 6 TRANSPORT SC blowers and exhausters must be transported by adequate equipment suitable to their weight and packing dimensions and in accordance with the safety standard on force When transporting installing and performing maintenance it is important to grant a safe lifting of the machine using serviceable lifting slings instal...

Page 6: ...equent progressive increase of energy The pitch of the helicoidally trajectory changes in proportion with pressure variation between suction and discharge The pitch is able to self calibrate according to the load acting on the fluid The gas is free of pollution and keeps a linear flow without pulsations The absence of vibrations and a low noise level are further advantages and contribute to ease t...

Page 7: ...rated place where the ambient temperature is between 15 40 C humidity 80 at a maximum height of 1000 m above sea level When installing at different conditions it is necessary to consider the variation of gas characteristics pressure and weight and the downgrade of the motor s efficiency Surface treatments on the machine components are needed whenever humidity exceeds 80 If installed outdoors must ...

Page 8: ...SO 3744 measured at 1 m distance with no vacuum and or pressure restriction valve installed Tolerance 3 dB A Sound power level LW according to EN ISO 3744 Tolerance 3 dB A 12 CONNECTIONS WARNING All connections must be carried out by trained and specialized personnel 12 1 CONNECTION TO THE PLANT Connect the machine to the piping system by flexible connectors avoiding rigid connections that may cau...

Page 9: ... be preferred It is advisable to install a safety valve to avoid pressure overloads Connect the motor and check the rotating direction before piping connection The shaft direction of rotation is marked by an arrow on the fan guard of the electric motor The gas delivery direction is marked with arrows on both suction and discharge connections Pay attention not to confuse the suction and the dischar...

Page 10: ... phase motors with a rated voltage of 230V at 50Hz According to IEC 34 specification a 5 line voltage is allowed for motors with any other rated voltage at 50Hz and for any voltage at 60Hz All SC blower and exhauster are equipped with a KLIXON thermal protector See attached specification which must be connected to the main terminal box Warranty will be void in case of either misconnection or wrong...

Page 11: ...NDA 1 SIDE CHANNEL BLOWER EXHAUSTER 10 METALLIC FILTER 2 VACUUM PRESURE GAUGE 11 PIPING CONNECTIONS 3 SAFETY VALVE 12 PIPE CONNECTION 4 IN LINE FILTER 5 CARTRIDGE FILTER 6 SILENCER 7 IN LINE SILENCER 8 VACUUM PRESSURE GAUGE KIT 9 VALVE KIT 13 START UP ...

Page 12: ... missing phase frequent start ups excessive voltage variations clogging of the rotor the overload overheat protection is compulsory in order to prevent overload Adjust the protective motor according to the nominal value on the nameplate as maximum value At machine start up it s necessary To check the operating pressure by a pressure gauge or a vacuum gauge To check the calibration of the safety va...

Page 13: ...rt of the machine with compressed air Deposit of dust on external blower surface avoid an adequate thermal exchange and can cause an overheating of the interior Clean the ventilation grid of the motor fan cover Dirt on motor fan cover reduces the air flow and causes motor overheating Every 10 15 days during operation it is advisable to clean the filter cartridge If the machine operate in a high du...

Page 14: ... the screws 45 holding the flange Unscrew the tie rod 26 remove the silencer paying attention not to lose the flat gasket 22 Replace the net silencer 23 and the silencer insert 24 Reassemble the machine reversing the disassembly procedures 14 2 SEALING RINGS AND BEARINGS REPLACEMENT The sealing rings lose the sealing capacity when exceeding their lifetime max 2 years thus allowing fluid losses At ...

Page 15: ...gged Check and replace the motor Reduce throttling if necessary clean filters silencer and connection pipes See point 2 2 4 The machine does not deliver differential pressure or the pressure is too low 4 1 Leak in system 4 2 Wrong sense of rotation 4 3 Wrong frequency 4 4 Shaft seal defective 4 5 Different density of gas 4 6 Change in blade profile due to dirt Seal the leak Reverse direction of ro...

Page 16: ...ds on force 18 REPAIR Due to the accuracy required in performing disassembly and assembly procedures of SC blowers and exhausters they must be carried out only by trained and skilled personnel If necessary the machine can be returned back to I VA CO SRL for repair recommended action 19 SPARE PARTS To order spare parts necessary to repair the following information are mandatory Part description Ite...

Reviews: