background image

 

IACER SRL                                                 Page 7 di 22                           MNPG80-01 of 06/05/2016 

 

Power  Q-6000 Plus is equipped with: 

 

 

machine body 

 

double leggings (1) 

 

2 derivations connection tubes for leggings (2) 

 

2 pressure plantars (3) 

 

abdominal band (4) 

 

1 derivation connection tubes for abdominal band (5) 

 

armband (6) 

 

1 derivation connection tubes for armband (7) 

 

2 pairs of TNT leggings 

 

air stopped jack 

 

power supply cable 

 

Optional accessories: 

 

extensions for leggings (8) 

 

Accessories size 

 

Legging:  

 

Length around 

 

86 cm (from upper side to heel)

 

 

Thigh circumference around 71 cm  

 

Ankle circumference around 42 cm 

 

 
Armband: 

 

Max. length around 86 cm  

 

Biceps circumference around 50 cm  

 

Wrist circumference around 36 cm  

 
Abdominal band: 

 

Length around 136 cm  

 

Height around 46 cm  

 

Velcro height around 31 cm  

 

Summary of Contents for Power Q-6000 Plus

Page 1: ...USER MANUAL MNPG80Rev 1Edition 06 05 2016 Compressive Limbs Therapy model Power Q 6000 Plus...

Page 2: ...I A C E R Srl Via S Pertini 24 A 30030 Martellago VE ITALY Tel 041 5401356 Fax 041 5402684 e mail iacer iacer it http www iacer ve it...

Page 3: ...ic display detail 5 Accessories 6 Accessories size 7 Specifications 8 Technical Specifications 8 Purpose 8 Labelling 9 Working instructions 10 Troubleshooting 15 Warnings 16 Warranty 20 Assistance 20...

Page 4: ...ged sanguine vessels or in body zones not correctly bedewed External compression allows excess interstitial fluids to return in circulatory system in order to be quickly removed Most common applicatio...

Page 5: ...5 di 22 MNPG80 01 of 06 05 2016 Machine body Graphic display detail 1 MODE mode selector A1 A2 B C D1 D2 D3 D4 D5 D6 2 SPEED speed selector Speed 7 42 sec Speed 8 48 sec Speed 9 54 sec Air discharge...

Page 6: ...step of 5 4 PRESSURE pressure selector from 0 to 240 mmHg by step of 1 5 START STOP start stop selector 6 LCD graphic display Accessories 1 DOUBLE LEGGINGS 2 DERIVATIONS CONNECTION TUBES FOR LEGGINGS...

Page 7: ...rivation connection tubes for armband 7 2 pairs of TNT leggings air stopped jack power supply cable Optional accessories extensions for leggings 8 Accessories size Legging Length around 86 cm from upp...

Page 8: ...ainst liquids penetration Equipment and accessories not subjected to sterilization Use of the equipment is prohibited close to flammable substances or in environments with high concentrations of oxyge...

Page 9: ...ect to WEEE regulations concerning separate waste collection of electronic equipment Part applied BF Class II equipment Compliance with Directive 93 42 EEC and following modifications Manufacturing da...

Page 10: ...of the device Working instructions 1 Connect cable to the domestic plug 220 240 VAC then turn ON the ON OFF switch 2 Wear the applicators N B The two machine outputs can be used indifferently with an...

Page 11: ...tube to the higher position connector of legging thigh both the longer tube and the higher position connector have a darker color v After connecting the tubes to the relatives leggings connect the tu...

Page 12: ...topped jack equipped with the body machine d Simultaneous use of abdominal band and leggings i Wear the leggings please read Leggings use paragraph and the abdominal band please read Abdominal band us...

Page 13: ...y A2 Air flows in compression chambers till they reach pressure regime Then air flows in the sixth chamber upper limb according to adjusted pressure and sequentially in the other chambers in a proxima...

Page 14: ...ctor on graphic display a Select airflow speed by pressing SPEED button You can choose between 8 speed levels b It s not possible to change airflow speed during the treatment 5 Therapy time selection...

Page 15: ...the graphic display a Press START STOP button to start the therapy any moment it s possible to stop the treatment pressing again START STOP button the device memorizes the adjusted time b Press STOP b...

Page 16: ...up in a progressive way Air goes into the compression chambers and or an air leakage is present in the applicators Check if there are any holes or damages in the compression chambers If there are not...

Page 17: ...vice Liquid penetration could damage the device In case of suspected malfunctioning do not open or repair the device Do not use the device Electric shock risk Contact the distributor or fabricant Do n...

Page 18: ...from domestic plug when not in use Do not press bend or damage the electric cable Electric shock risk Avoid to connect more devices to the same multiple plug Overheating risk Avoid device hits or dro...

Page 19: ...eatment Do not place any objects on the device or on its parts connector tubes applicators etc If you not use the device for a long time or if you use the device in cold places a malfunctioning may ha...

Page 20: ...m 10 to 90 pressure from 500 to 1060 hPa Warranty Concerning the warranty make reference to the national laws by contacting the national distributor or directly the fabricant IACER Assistance Every in...

Page 21: ...041 5402684 To preserve product warranty functionality and product safety we recommend to use only original spare parts POWER Q 6000 Plus is manufactured by IACER Srl is the mandatary nominated by th...

Page 22: ......

Reviews: