IACER Srl 

23 

MNPG71-06 

Technical  documentation  related  to  repairable  parts  could  be  attached,  but 
only with previous authorization from the manufacturer and only after giving 
proper training to the staff employed in technical assistance. 

Spare part 

The manufacturer makes available at any time the original spare parts for the 
equipment. Please contact: 

I.A.C.E.R. S.r.l. 

Via Enzo Ferrari, 2 

• 3003

7 Scorzè (VE) 

Tel. 041.5401356 • Fax 041.5402684

 

In  order  to  preserve  the  warranty,  the  functionality  and  the  security  and 
safety of the product, it  is highly  recommended to use exclusively the spare 
parts given by the manufacturer. 

Electromagnetic 

interferences 

and 

electromagnetic 

compatibility tables 

The  MIO-SONIC  equipment  has  been  designed  and  manufactured  according 
to  the  TECHNICAL  STANDARD  on  ELECTROMAGNETIC  COMPATIBILITY 
legislation EN 60601-1-2:2015 with the aim of providing adequate protection 
from  harmful  interference  when  installed  in  homes  and  health 
establishments. 
According  to  operating  principles  the  device  does  not  generate  significant 
radio  frequency  energy  and  is  adequately  immune  to  radiated 
electromagnetic  fields:  under  such  conditions  it  does  not  detrimentally 
harmful  interfere  with  radio-electric  communications,  electro-medical 
equipment  for  monitoring,  diagnosis,  therapy  and  surgery,  office  electronic 
devices such as computers, printers, photocopiers, fax machines, etc. or any 
electric  or  electronic  equipment  used  in  these  environments,  as  long  as  the 
equipment complies with the ELECTROMAGNETIC COMPATIBILITY directive. 
In any case, in order to avoid any interference problems, it is recommended 
to  use  the  therapy  equipment  enough  far  away  from  critical  equipment  for 
monitoring vital patient functions, and to be careful when applying therapy to 
patients  with  pacemakers.  In  any  case  it  is  recommended  to  use  the 
equipment at least at 3 meters away from televisions, monitors, cellphones or 
any other electronic equipment. 

MIO-SONIC.  All  rights  reserved  MIO-SONIC  and  the  logo 

  are 

property exclusively of I.A.C.E.R. Srl and registered. 

Edition: MNPG71-06 of the 31/01/2022 

Summary of Contents for Mio-Sonic

Page 1: ...USER MANUAL Ultrasound therapy MIO SONIC...

Page 2: ......

Page 3: ...ESCRIPTION 5 LABELLING 5 Package content 6 HOW TO USE 7 INTRODUCTION TO THE TECHNOLOGY 7 CONTRAINDICATIONS 9 Side effects 9 WARNINGS 9 DEVICE USE 11 Antalgic and de contracting treatments 14 Beauty tr...

Page 4: ...Directive 93 4 EEC transposed in Italy by the D Lgs 46 97 as modified by the Directive 2007 47 EC D Lgs 37 2010 and further modifications integrations The product has been assigned to class IIa accord...

Page 5: ...s ideal for the treatment of muscular and nervous pathologies and for the recovery of traumas in case of both chronic and acute pathologies In fact ultrasound therapy is indicated for antalgic treatme...

Page 6: ...lation 100Hz 10 Waveform Pulsed Modulation duty cycle L 5 M 50 H 100 Regolation intensity Adjustable on 3 steps L M H Ultrasound head 5 cm Effective radiant area 4 cm 20 Ultrasonic beam Collimated Hea...

Page 7: ...NPG71 06 Device and commands description 1 Time indicator light 2 Time button 3 Power indicator light 4 Intensity indicator light 5 Mode button 6 Power switch 7 Ultrasound head 8 AC DC adapter connect...

Page 8: ...for the disposal of electronic waste Applied part type BF Class II device IPX7 Degree of protection from temporary immersion under water up to 1m of depth and up to 30 minutes only for the ultrasound...

Page 9: ...gy angiology and cardiology these technologies in fact exploit the return echo deriving from an ultrasonic beam which propagates inside the human body and which is slowed down in a different way depen...

Page 10: ...ts into formation of steam zones within the fluid The dissolved gasses within the fluid they aggregate as a result of the lowering of pressure realized by the ultrasound forming bubbles or cavity cont...

Page 11: ...s from epilepsy phlebitis in place thrombophlebitis in feverish state anxiety or serious illnesses vein thrombosis severe osteoporosis inflammation arteriopathies except in case of medical prescriptio...

Page 12: ...n environments with high concentrations of oxygen with aerosol therapy devices or in wet environments use of the device is prohibited in bathroom or shower areas or while showering bathing to use the...

Page 13: ...t immediately and consult the retailer or manufacturer Consult a doctor before using MIO SONIC with metallic osteosynthesis devices IF YOU HAVE ANY DOUBTS REGARDING THE DEVICE USE CONSULT YOUR DOCTOR...

Page 14: ...reated so that it is free of oil and dirt Apply a generous layer of ultrasound transmission gel on the treatment area The gel is fundamental to ensure a correct fit between the treated area and the ul...

Page 15: ...M for H intensity is recommended maximum attention in maintaining in continuous moving the ultrasound head The intensity L corresponds approx to 0 08W cm the intensity M approx to 0 80W cm and intens...

Page 16: ...ycle of therapy with an average duration of 10 minutes each for a maximum period of 21 days In case the pain persists stop for 7 days the treatment and eventually restart another therapy cycle of 21 d...

Page 17: ...ion of liquids and it is present in the adipose tissue especially arround the ankles the calves and it affects subjects with a good health and with a tonic musculature Flaccid is manifested in middle...

Page 18: ...will vary from 20 to 30 minutes This job can be performed at intervals of hours or days between an area and the adjacent one or in rapid sequence The use of lotions or gel containing active principles...

Page 19: ...nee gluteus arms abdomen with maximum ultrasound intensity at M Programs Area Intensity N app tot Frequency Thighs drainage M H 20 Daily Thighs compact cellulite M H 30 Daily Thighs flaccid cellulite...

Page 20: ...flaccid cellulite L M 20 Daily Arms edematous cellulite L M 20 Daily Abdomen drainage L M 20 Daily Abdomen compact cellulite L M 25 Daily Abdomen flaccid cellulite L M 30 Daily Abdomen edematous cell...

Page 21: ...e removed using a sponge soaked in solution of water and alcohol Device not subject to sterilization Note Never use solvents for cleaning Cleaning agents cause damage to the device Attention to the ne...

Page 22: ...erly Check the socket operation Network cable not correctly inserted in the registered connector Insert the plug and cable correctly into the device connector Network cable worn out and interrupted Re...

Page 23: ...for recycling of electrical and electronic equipment For further information on the obsolete equipment disposal please contact the dedicated disposal service or the shop in which the device was bough...

Page 24: ...paration or free substitution hand work included 5 Warranty is not applied to damages caused by negligence or use not compliant to the given instructions by intervention on the device from personnel n...

Page 25: ...es and health establishments According to operating principles the device does not generate significant radio frequency energy and is adequately immune to radiated electromagnetic fields under such co...

Page 26: ...o 1 Group 1 Il MIO SONIC utilizza energia RF solo per il suo funzionamento interno Perci le sue emissioni RF sono molto basse e verosimilmente non causano nessuna interferenza negli apparecchi elettro...

Page 27: ...should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 Transitori treni elettrici veloci Electrical fast transient burst IEC...

Page 28: ...5 cicli cycles 5 UT 95 buco in dip in UT per for 5s 40 UT 60 buco in dip in UT per for 5 cicli cycles 70 UT 30 buco in dip in UT per for 25 cicli cycles 5 UT 95 buco in dip in UT per for 5s anche dura...

Page 29: ...espected calculated from the equation applicable to the frequency of the transmitter Distanza di separazione raccomandata Recommended separation distance RF condotta Conducted RF IEC 61000 4 6 3Veff d...

Page 30: ...essere previste teoricamente e con precisione Per valutare un ambiente elettromagnetico causato da trasmettitori RF fissi si dovrebbe considerare un indagine elettromagnetica del sito Se l intensit di...

Page 31: ...aximum output power of transmitter W Distanza di separazione alla frequenza del trasmettitore m Separation distance according to the frequency of the transmitter m 1 2 150 80 150 800 0 35 80 800 80 80...

Page 32: ......

Reviews: