INTRODUCTION OF THE TECNOLOGY 

The evolution of light  

The new Laser I-TECH LA 500  is equipped with a new probe that allows beam laser 
application  directly  to  the  treatment  area.  Thus  you  can  make  sure  that  the  laser 
performs  its  therapeutic  action  as  an  impressive  regenerative  stimulation in  chronic 
pathologies, in the acceleration of the inflammation resolution and of the oedema in 
acute  pathologies,  and  in  the  rapid    resolution  of  painful  articular,  muscular, 
neurogenal and soft tissues syndromes, both acute and chronic. 

I-TECH  LA500  allows  an  immediate  improvement  in  the  symptoms  of  inflammatory 
and  degenerative  pathologies  in  the  orthopaedic,  neurologic,  dermatologic  domain 
and  a  reduction  of  recovery  times  and  presents  itself  as  an  indispensable  therapy, 
especially in Sports Medicine, since it allows rapid recovery for many sportsmen, for 
whom time is a determining factor in their career.   

 

The advantages of Laser therapy  

Laser  therapy  is  not  based  on  the  generation  of  heat,  but  on  photochemical  and 
photo-biological effects on cells and tissues. Observations have shown that if the laser 
light is supplied in the right quantities, you will obtain a stimulation of certain cellular 
functions,  especially  in  the  presence  of  cells  with  functional  deficiencies.  The 
biological action in using the Laser therapy produces a series of effects on the cells in 
function  of  a  “stimulating”  action  on  mitochondrial  functions  with  a  higher 
production of ATP.  

The  applications  of  the  I-TECH  LA500  laser  produce  a  number  of  effects  on  the 
treated tissues: 

1.

 

increase in hematic flow: vasodilatation of capillaries and arteries 

2.

 

biostimulation:  tissue  regeneration,  stimulation  of  the  protein  synthesis, 
stimulation  of  the  production  of  ATP,  stimulation  of  the  fibroblast  mitosis, 
increase in collagen and elastin;  

3.

 

anti-inflammatory effect; 

4.

 

anti-edematous effect, with stimulation of the lymphatic system; 

5.

 

analgesic effect: increase in the perception threshold of nerve endings. 

I-TECH LA500 is therefore a laser with the following characteristics: 

-  thanks  to  the  power  adjustable  up  to  500mW  and  to  the  810  nm  wavelength,  it 
allows the stimulation of the deepest layers of the treated tissue thus favoring a rapid 
and diffused cellular re-generation; 

- with I-TECH LA500 it is possible to obtain a deep tissue stimulation and this makes 
possible to treat the most internal tissues and structures (such as the femoral joint) 
and chronic pathologies such as arthrosis; 

-  it  may  be  used  in  many  fields  such  as  sports  medicine,  orthopedics,  neurology, 
dermatology,  rheumatology,  odontology  (conservative  parodontology,  medical 
treatment  by  implants,  oral  pathology,  surgery,  removal  of  tartar  with  pain)  and 
acupuncture 

- crucial in acute, chronic and degenerative inflammations such as knee arthritis. 

I-TECH  LA500  carries  out  an  important  therapeutic  action  for  the  regeneration  of 
chronic  pathologies,    for  the  acceleration  of  the  healing  process  in  the  acute 
pathology  of  edema  inflammation.  Furthermore  it  is  very  effective  in  the  fast 
resolution of painful articular, muscle, neurogenic  syndromes and soft tissues.  

 

 

 

Summary of Contents for LA500

Page 1: ...I A C E R Srl MNPG127 02 06 06 17 LASER THERAPY...

Page 2: ......

Page 3: ...E 8 INDICATIONS 8 CONTRA INDICATIONS 8 DEVICE DESCRIPTION 9 PATIENTS PREPARATION 9 HOW TO USE IT 9 Therapeutic indications 11 MAINTENANCE 13 HANDLES CLEANING 13 WORKING PROBLEM 13 ELECTROMAGNETIC INTE...

Page 4: ...important information and useful tips for operating the equipment CAUTIONS The CAUTION message appears before operations which if not correctly performed may cause damage to the machine and or its acc...

Page 5: ...t use the equipment in places where it might get wet Before operating the machine carefully check the correctness of the connections according to the instructions Do not use accessories other than the...

Page 6: ...ecution of different procedures from those specified in this user manual can cause the exposition to dangerous radiation The operator has the responsibility to verify that the issuing head remains wel...

Page 7: ...er production of ATP The applications of the I TECH LA500 laser produce a number of effects on the treated tissues 1 increase in hematic flow vasodilatation of capillaries and arteries 2 biostimulatio...

Page 8: ...ensitive to laser radiation and can be permanently damaged from direct or reflected laser beams The special safety glasses must be worn by both patient by the operator pregnancy the laser is contraind...

Page 9: ...of the patient for the therapy carry out the following operations 1 wash the skin using soap and mild soap or alcohol where the head of the laser will be positioned 2 dry well the skin HOW TO USE IT...

Page 10: ...ent time last 3 minutes Select the operation mode CONTINUOS or CYCLE using the buttons on the right side of the front panel picture below With CYCLE mode it is possible to select the ON time from 1 to...

Page 11: ...ition upper picture Take away the key from the machine to avoid the use by unauthorized personnel Please do not switch off the device unplugging the cable from the power socket to avoid any type of da...

Page 12: ...ITIS 0 3 66 sec 264 sec BAKER S CYST 0 3 66 sec 264 sec DE QUERVAIN SYNDROME 0 2 100 sec 400 sec OEDEMA 0 3 66 sec 264 sec HEMATOMA 0 3 66 sec 264 sec EPICONDYLITIS 0 4 50 sec 200 sec HERNIATED DISC 0...

Page 13: ...ent HANDLES CLEANING The laser handle is very weak and it needs a daily cleaning The following advices are absolutely important to not damage the lens and the laser probe It is suggested to 1 Remove t...

Page 14: ...that the socket works properly The power cable is not inserted correctly into the connector of the device Insert correctly the plug and the cable in the connector of the device The power cable is wor...

Page 15: ...B Output channels 1 Class of isolation parts applied according to the rule EN 60601 1 I BF Protection level against the liquids penetrations according to the rule EN 60601 1 IPX0 Command of execution...

Page 16: ...that the product shall not be disposed of as domestic waste The user must dispose of scrap equipment by taking it to a recognized centre of recycling of electrical and electronic equipment Appendix B...

Page 17: ...ctrostatic discharge ESD IEC 61000 4 2 6kV contact 6kV contact Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30...

Page 18: ...th accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the ME EQ...

Page 19: ......

Page 20: ......

Page 21: ...nd warehouse 30030 MARTELLAGO VE Via S Pertini 24 A Tel 0039 041 5401356 Fax 0039 041 5402684 Cod Fisc P IVA IT 00185480274 R E A VE N 120250 M VE001767 e mail iacer iacer it Internet www itechmedical...

Reviews: