i-team i-gum User Manual Download Page 1

 

i-gum

 

Portable gas chewing gum removal system 

User manual 

 

i-team Professional b.v.

 

Hoppenkuil 27b, 5626 DD Eindhoven, The Netherlands 
T +31402662400  
[email protected] 
I  www.i-teamglobal.com 

 

 

Summary of Contents for i-gum

Page 1: ...i gum Portable gas chewing gum removal system User manual i team Professional b v Hoppenkuil 27b 5626 DD Eindhoven The Netherlands T 31402662400 E hello i teamglobal com I www i teamglobal com ...

Page 2: ...nglish Language Future Cleaning Technologies B V Hoppenkuil 27b 5626 DD Eindhoven The Netherlands T 31402662400 E hello i teamglobal com I www i teamglobal com Model I GUM GAS VERSION Date 08 07 2019 Product code IGM I V 1100C 1 Version v 01 ...

Page 3: ...ound on top of the main body Your i team dealer needs this number when you order parts When this manual refers to the manufacturer this means Future Cleaning Technologies B V an affiliate company of i team in Eindhoven the Netherlands When this manual mentions the partner your local i team resell and support service partner is referred to Purpose of the user manual The purpose of the user manual i...

Page 4: ...uld keep a minimal distance of 6 inch 15 cm In this specific case operators may not use the machine as a backpack PRESSURIZED CYLINDER Indicates a gas operated machine gas cartridges must be installed according tot the instructions in this user manual Gas cartridges must be disposed of according to your local laws and regulations BATTERIES Indicates a battery operated machine batteries must be cha...

Page 5: ...ty Instructions 13 3 1 1 Trolley operation 13 3 1 2 Backpack operation 14 3 1 3 Brush condition 14 3 1 4 Machine orientation 14 3 1 5 Strong magnets 14 3 1 6 Gas cartridges 14 3 1 7 Batteries 14 3 2 Risks during operation 15 3 2 1 Careful hot surface 15 3 2 2 The gum remover solution 15 3 2 3 Personal protection 15 3 2 4 Mark the job site 15 4 Transport and storage 16 5 Assembly and installation 1...

Page 6: ...33 6 4 2 After operation 33 6 5 Cleaning and storage 35 6 5 1 Drain the machine 35 6 5 2 Rinse the machine 36 6 5 3 Remove the gas cartridges 36 6 5 4 Storage 37 7 Maintenance 38 7 1 Brush replacement 38 7 2 Recommended additional cleaning 39 7 2 1 Clean with water 39 7 2 2 Drain the machine 40 7 2 3 Rinse the machine 41 7 2 4 Replace the fuse 42 7 3 Recommended service time 43 8 Trouble shooting ...

Page 7: ...se refer to the instructions at the charger and this manual for correct procedure This manual is intended for those who work with the i gum and perform daily maintenance The manual must be read in full before the first actions This manual describes the correct method of use safety measures maintenance and transport And finally the manual contains information about the consumables the gum remover s...

Page 8: ...wing gum patches on floors It is only effective using the specialized water based i gum gum remover solution Filling the tank with clear water will not remove gum patches and therefore is pointless The steam lance may not be raised higher than horizontal during operation as the hot gum remover solution cleaning fluid can cause burns see Figure 1 DO NOT fill the i gum with any other detergent Alter...

Page 9: ... Length 1 3 M Li on Battery 14 8V 6 6Ah Gas Cartridge Drawer Capacity 2 Gas Cartridges Operation Time of Gas Cartridges About 4 hours Cartridge About 8 hours 2 Cartridges Fluid Flow Speed Class Low Middle High Tank Capacity 2 5 L Control Panel in Handle YES Trolley Handle YES Transport Wheel YES Backpack for Body Unit YES Fluid Shortage Warning YES Figure 2 ...

Page 10: ...ative supplies voids manufacturer s warranty 1 7 Identification Each i gum has a unique identification number that can be found on top of the main body Your i team dealer needs this number when you order parts Explanation type plate Product type i gum G Serial number G17322038 Power supply and capacity DC 12V 5W Manufacturer Future Cleaning Technology B V Country of assembly PRC Figure 3 ...

Page 11: ...The steam lance with the integrated gas heating installation to deliver the heated gum cleaner solution exactly on the gum patch The brush attached to the steam lance is not intended for scrubbing only a light agitation is needed The heated solution will break down the chewing gum in a matter of seconds A broom is provided to sweep away the gum residue The i gum consists of Figure 4 ...

Page 12: ...ator 8 A fuse holder 9 A drip tray to avoid spillage 10 A broom and broom holder to sweep the gum residue 11 The steam lance with an integrated gas heating Installation and a separate brush connected to the body 12 The SELF LOCK button 13 The main body 14 The gum remover solution tank sealed by a yellow stopper 15 Wheels and a handle to use the i gum as a trolley 16 The back plate and harness to u...

Page 13: ...owever the grey part fig 5 pos 1 should not be touched The temperature stays well below 60 C CAUTION Always keep the body of the i gum in an upright position when gum remover solution or batteries are inserted 3 1 1 Trolley operation CAUTION When using as a trolley remove the harness as the machine can trip over loose straps It is recommended to keep the steam lance Figure 5 pos 1 stored in its ho...

Page 14: ...ce is cooled 3 1 4 Machine orientation Always keep the body of the i gum in an upright position when gum remover solution or gas cartridges are inserted 3 1 5 Strong magnets CAUTION Please be aware of the integrated magnets that hold the steam lance in its holder WARNING Operators and maintenance crew wearing pacemakers should keep a minimal distance of 6 inch 15 cm Operators wearing pacemakers sh...

Page 15: ... general safety rules Keep locked up and out of reach of children Keep away from food drink and animal feedstuffs When swallowed seek medical advice immediately and show the bottle DO NOT induce vomiting 3 2 3 Personal protection CAUTION Can be irritating to the eyes wear eye protection and use caution when filling CAUTION Clean your hands immediately after filling or draining the machine CAUTION ...

Page 16: ...t expose the i gum to open fire Drain the machine after each use before storage or during transport see 6 5 1 Store the steam lance in its holder during transport and storage The gas cartridges can remain in the machine during storage and transport Store the i gum in an upright position under normal storage conditions Don t expose the i gum to open fire ...

Page 17: ...r package of brushes gas cartridges and cleaning fluid 2 The battery charger and the storage bag for the battery charger Legend 1 1x i gum main body harness attached 7 1x drip tray 2 1x broom 8 1 x storage tube for spare brushes 3 1x battery charger 220 V plus cable and storage bag 9 3x steel brushes one attached to the steam lance 4 2x gas cartridges 10 2x nylon brushes 5 4x bottles of gum remove...

Page 18: ...older Figure 8 pos 3 with the metal plate facing the main body 3 Screw the broom on the broom handle 4 Place the broom in the broom holder Figure 8 pos 4 5 Place the spare brushes in the storage tube Figure 8 pos 6 6 Attach the storage bag for the battery charger Figure 8 pos 5 to the body if desired Figure 7 ...

Page 19: ...lley operation When you use the i gum as a trolley it is advised to remove the harness so loose straps cannot be caught between the wheels To remove the harness 1 Remove padding Figure 9 pos 1 that is attached to the back plate with Velcro Figure 8 ...

Page 20: ...20 2 Unscrew the four screws Figure 10 pos 1 using a Philips screwdriver 3 Remove the back plate Figure 10 pos 2 Figure 9 ...

Page 21: ...back in place as these also hold the trolley handle Figure 11 pos 1 5 3 2 Backpack operation When you use the i gum as a backpack no further assembly is required TIP Keep all removed parts safely stored for future use Figure 10 ...

Page 22: ...achine check the battery power indicator 6 1 1 Charge the battery 1 Make sure the i gum is turned off 2 Remove the battery charger Figure 12 pos 6 from the storage bag Figure 12 pos 1 3 Connect the battery charger plug Figure 12 pos 5 to the socket Figure 12 pos 3 4 Disconnect the charger when ready The battery does not need to be fully charged before use WARNING Don t charge the built in battery ...

Page 23: ...artridge clockwise right to tighten it Figure 13 pos 3 4 Install the second gas cartridge push the cartridge upwards into the second cartridge slot Figure 13 pos 3 turn the cartridge clockwise right to tighten it Figure 13 pos 3 5 Close the gas cartridge holder pull the safety pin at the back of the the i gum Figure 13 pos 1 close the gas cartridge holder Figure 13 pos 4 at the same time TIP It is...

Page 24: ...achine via the main power switch Figure 15 pos 2 and refill the gum remover solution tank see 6 1 3 6 2 Dry start When using the i gum for the first time the machine needs to start up the pump and fill the pipes with cleaning fluid This also applies to machines that are rinsed before storage see 6 5 2 1 Turn on the i gum using the main power switch on the bottom Figure 15 pos 2 left of the body 2 ...

Page 25: ...raph 6 4 when you are using the harness 1 Walk to the job site with the i gum and a wet floor marker 2 Mark the job site 3 Turn on the i gum using the main power switch on the bottom Figure 17 pos 2 left of the body 4 Check the battery power indicator Figure 17 pos 1 see 6 1 1 for charging the built in battery Figure 14 ...

Page 26: ...ht L is on the pump runs in full speed 14 Release the H M L multi function button Figure 17 pos 5 when rinse indicator light is on 15 Press the SELF LOCK button to start the gas flow Figure 17 pos 8 CAUTION The gas will flow as long as this button is locked 16 Press the IGNITION button Figure 17 pos 6 for 2 seconds You can hear the gas heater is burning The pump starts 17 Wait for 20 seconds until...

Page 27: ...27 Figure 16 ...

Page 28: ...e 17 TIP Pump speed high only increases the amount of cleaning fluid this can be effective for rough surfaces or carpet cleaning On flat surfaces the additional fluid will run off and have no effect 6 3 2 After operation 1 Turn off the SELF LOCK button Figure 18 pos 4 2 Turn off the pump via the ON OFF button Figure 18 pos 1 The H M L indicator light goes out The pump and the pump Figure 18 pos 5 ...

Page 29: ...cartridge holder Figure 19 pos 4 at the same time 4 Turn off the gas valve Figure 19 pos 2 5 Close the gas cartridge holder pull the safety pin at the back of the i gum Figure 19 pos 1 close the gas cartridge holder Figure 19 pos 4 at the same time 6 Turn off the i gum via the main power switch Figure 18 pos 3 Figure 19 ...

Page 30: ...arging the built in battery 3 Open the gas cartridge holder pull the safety pin at the back of the i gum Figure 20 pos 1 pull the gas cartridge holder Figure 20 pos 4 at the same time 4 Turn on the gas valve Figure 20 pos 2 5 Close the gas cartridge holder pull the safety pin at the back of the i gum Figure 20 pos 1 close the gas cartridge holder Figure 20 pos 4 at the same time Figure 20 ...

Page 31: ...t floor marker 11 Mark the job site 12 Take the lance from the holder 13 Press the ON OFF button Figure 22 pos 7 on the handle control 14 Press the H M L multi function button Figure 22 pos 5 15 Hold for 5 seconds this will start the pump 16 Check the H M L indicator light Figure 22 pos 4 When the indicator light L is on the pump runs in full speed 17 Release the H M L multi function button Figure...

Page 32: ...ance The i gum is ready for use 21 Check the H M L multi function indicator light Figure 22 pos 5 The pump will default operate at low speed see 6 3 1 22 Place the brush on the piece of flattened gum 23 Agitate the brush in circular motion until the gum disintegrates 24 DO NOT scrub or apply pressure it is not required and it can harm the surface 25 Use the broom to sweep the disintegrated gum 26 ...

Page 33: ...fter 3 minutes as the ventilator needs to be cooled before storage 3 Open the gas cartridge holder pull the safety pin at the back of the i gum Figure 23 pos 1 pull the gas cartridge holder Figure 23 pos 4 at the same time 4 Turn off the gas valve Figure 23 pos 2 5 Close the gas cartridge holder pull the safety pin at the back of the i gum Figure 23 pos 1 close the gas cartridge holder Figure 23 p...

Page 34: ...os 4 7 Turn off the i gum via the ON OFF switch on the handle control Figure 24 pos 1 8 Remove the backpack and close the strap Figure 24 pos 2 to hold the waistband together 9 Turn off the i gum via the main power switch Figure 24 pos 3 Figure 24 ...

Page 35: ...side towards you 2 Release the drainage tube Figure 25 pos 2 via the clips Figure 25 pos 1 3 Put the end of the drainage tube in an empty gum remover solution bottle 4 Remove the yellow stopper from the fluid tank Figure 26 pos 1 5 Open tap Figure 25 pos 3 6 When empty close tap Figure 25 pos 3 7 Replace the yellow stopper Figure 26 pos 1 8 Replace drainage tube Figure 25 pos 2 using the clip Figu...

Page 36: ... ON OFF button Figure 28 pos 2 on the handle control 6 Press the H M L multi function button Figure 28 pos 1 7 Hold the H M L multi function button Figure 28 pos 1 8 Wait until no more fluid comes from the lance 9 Press the ON OFF button Figure 28 pos 2 on the handle control 10 Turn off the main power switch Figure 24 pos 3 11 Remove the drip tray and clean Figure 27 Figure 28 After the rinse oper...

Page 37: ...to remove it Figure 29 pos 3 4 Remove the second gas cartridge turn the second cartridge counterclockwise left to remove it Figure 29 pos 3 5 Close the gas cartridge holder pull the safety pin at the back of the the i gum Figure 29 pos 1 close the gas cartridge holder Figure 29 pos 4 at the same time Figure 29 Remove the empty gas cartridges for separate disposal If you want to insert new gas cart...

Page 38: ...are sharp and bended after use make sure you do not cut yourself and grab the brush by the top 1 Make sure the i gum is turned off and completely cooled down 2 Unscrew the old brush by a small turn clockwise right and pull Figure 31 3 Take a new brush and press and turn counterclockwise left until in place Figure 32 Figure 30 Figure 31 ...

Page 39: ... 5 Press the ON OFF button Figure 34 pos 2 on the handle control 6 Press the H M L multi function button Figure 34 pos 1 7 Hold for 1 minute this will start the pump 8 Release the H M L multi function button Figure 34 pos 1 9 Wait for 20 seconds until steam comes out of the lance 10 Allow some steam to come out to clean the steam lance 11 Turn off the machine via the ON OFF button Figure 34 pos 2 ...

Page 40: ...Figure 34 pos 1 3 Put the end of the drainage tube in a bucket or empty bottle 4 Remove the yellow stopper from the fluid tank Figure 35 pos 1 5 Open tap Figure 34 pos 3 6 When empty close tap Figure 34 pos 3 7 Replace the yellow stopper Figure 35 pos 1 8 Replace drainage tube Figure 34 pos 2 using the clips Figure 34 pos 1 Figure 34 Figure 35 ...

Page 41: ...L multi function button Figure 37 pos 1 6 Hold for 1 minute this will start the pump 7 Release the H M L multi function button Figure 37 pos 1 8 Wait until no more steam comes out of the lance 9 Turn off the machine via the ON OFF button Figure 37 pos 2 10 Turn off the main power switch 11 Clean the drip tray Figure 37 pos 2 Figure 37 After the rinse operation the machine Is completely dry Next ti...

Page 42: ...ke sure the i gum is switched off before you replace the fuse Replace the fuse 1 Make sure the i gum is switched off 2 Unscrew the fuse holder Figure 39 pos 2 using a screwdriver 3 Replace the fuse Figure 39 pos 1 by a new fuse 4 Close the fuse holder Figure 39 pos 2 using a screwdriver Figure 38 ...

Page 43: ...you do not have a service agreement check the timer on the bottom left side of the machine on a regular basis It is recommended to schedule a full service by one of our service partners every 1 000 hours Check the timer on a regular basis ...

Page 44: ...act your service department Pump is not running Pump needs to be replaced by a skilled mechanic Steam is blocked Turn off the machine check and clean the brush and steam nozzle Fluid level LED light flashes Gum remover solution is low Turn off and cool down the machine Fill the tank with gum remover solution Fluid leak from tank Yellow stopper is not put back correctly Check and place the yellow s...

Page 45: ...able resources and needs to be disposed of according to your local laws and regulations regarding recycling of electrical equipment Before disposal please 1 Drain the machine see 6 5 1 2 Remove the gas cartridges for separate disposal see 6 5 3 3 Remove all loose components like brush holder and broom see 7 1 4 Dispose all items according to your local laws and regulations ...

Page 46: ...46 10 Attachments 10 1CE Certificate ...

Page 47: ...on the SAFETY DATA SHEET i GUM SDS number 23393 revision date 01 05 2015 This safety data sheet conforms to Regulation EC No 1272 2008 on Classification Labelling and Packaging of Substances and Mixtures This document is part of the technical file of the i gum chewing gum remover and will be available upon request ...