6
SAFETY
Read the “Safety” section of this Operating Manual carefully before using the device. If you
do not follow these instructions or do not understand them, this could lead to death, severe
injuries and damage to the device.
USER
Only trained users who are qualified in the use of Ex devices in explosion hazardous areas and
who have read and understood this Operating Manual may use this device.
EX-RELEVANT SAFETY REGULATIONS
Use of this device assumes that the operator observes the conventional safety regulations and
has read and understood Operating Manual, Safety Instructions and certificate. When used in
explosion hazardous areas, the following Safety Instructions must also be complied with:
The device may be connected only outside ex-hazardous areas to the
IS530.2
via the ISM
interface.
To ensure the IP-protection, it has to be ensured that all gaskets are present
and functional. There must be no large gap between the two halves of the housing.
The device must be securely fastened to the ISM interface when used in ex-hazardous areas.
The device may not be exposed to any aggressive acids or alkalis.
The device may only be used in zones 2 or 22.
Only accessories approved by
i.safe MOBILE GmbH
may be used.
EX-RELEVANT SAFETY REGULATIONS FOR NORTH AMERICA
Conditions of Acceptability:
The Barcode Scanner
IS-TH1xx.2
must be protected from impacts with high impact energy,
against excessive UV light emission and high electrostatic charge processes.
The 13-Pin connector of the
IS-TH1xx.2
may only be assembled or disassembled from the ISM
interface outside hazardous areas.
The 2 pin charging contacts of the
IS-TH1xx.2
should only be used in non-hazardous
locations.
Unauthorized repair is not allowed.
Apparatus is for use in pollution degree 2 or better.
Only designated charger may be connected to the charging contacts.
Not suitable for hazardous locations when enclosure is damaged.
USE IN EXPLOSION HAZARDOUS AREAS
DANGER
Improper use can result in death or severe injuries!
Only use the device in explosion hazardous areas of zones 2/22 or outside of
explosion hazardous areas.
Only connect the device outside explosion hazardous areas to the ISM interface of the
IS530.2
.
Summary of Contents for MTHA11
Page 1: ...IS TH1xx 2 OPERATING MANUAL SAFETY INSTRUCTIONS MODEL MTHA10 MTHA11...
Page 78: ...78 2 IS TH1xx 2 2 2 22 IS530 2 ISM ISM IS530 2 2 630 680 1 IS530 2...
Page 109: ...AR 109...
Page 110: ......
Page 112: ......
Page 116: ...WWW ISAFE MOBILE COM...