12
■
Indicators and buttons
A
INITIAL SET button (Initializing / NTSC
⇔
PAL switch button)
Follow the steps below to initialize the network camera.
(1) Turn off the power of the camera.
When using a PoE hub, disconnect the Ethernet cable from the camera. When using an
external power supply, disconnect the power cord plug (accessory) from the power supply
terminal (12V DC).
(2) Turn on the power of the camera while pressing the INITIAL SET button, and make sure to
release the button after approximately 15 seconds. In about 2 minutes later, the camera
will start up and the settings including the network settings will be initialized. Retry if the
camera does not start up normally.
IMPORTANT:
• When the camera is initialized, the settings including the network settings will be initialized.
Before initializing the settings, it is recommended to write down the settings in advance.
• Do not turn off the power of the camera during the process of initialization. Otherwise, it may
fail to initialize and may cause malfunction.
④
SD MOUNT
indicator
⑤
SD ON/OFF
button
①
INITIAL SET
button
②
LINK
indicator
③
ACT
indicator