The fuse on a unit repeatedly blows
•
Are you fitting right rating/type of fuse into unit?
•
Contact I-pix for more specific help with your problem, there may be an internal fault in the unit.
•
If you have the technical knowledge/skills you could look inside the unit and check the internal wiring for a lose
connections/shorts and also the power supply is working with a 15v output when
there is no load connected to it.
Dmx trouble shooting
The obvious
•
It is good practice to connect data line and terminate before switching on device.
•
Is the dmx line fitted to a buffer and data is being received
•
Is the dmx data line fitted with a line termination?
•
Does the unit’s dmx mode set-up match the personality/ profile for the console provided?
•
Note: the LCD screen flashes intermittently when no data is present