ISH HYBRID CONNECTOR Instruction Manual
Document No.
HDM-0009
21
/
24
Confidential C
10.
Unmating of connector
①
Hold the female connector and push it in lightly.
②
While holding the female connector in, press down fully on the end of the arm (see Fig. 43).
③
Keep pressing the lock down, and pull out the female connector.
Notes
①
Do not pull out the female connector without the lock arm fully pressed down.
It may cause damage or deformation to the connector.
②
Hold and pull the female connector (not the wires), when disengaging the female connectors.
③
If there is any damage or deformation, do not use the damaged item.
Replace the item with a new one.
11. Handling of Product
11-1. Conductivity test
11-1-1.
Male Connector
①
When carrying out conductivity test of the male connector, place the probe on the tip of the male terminal.
(Load:0.5N MAX.)
If load exceeds 0.5N, male terminal may be damaged or deformed. (see Fig. 44)
②
If there is any damage or deformation, do not use the damaged item.
Replace the item with a new one.
Fig 43.Lock arm
③
Pull out connector
Direction of pressing
Fig 44. Conductivity test for male terminals (contacts)
①
Push in lightly
Place the probe on the tip of the male terminal
Lock arm
②
Press down on the edge