水平方向

  Horizontal direction. / 

水平方向

 

本コネクタを安全に使用して頂く為に下写真の様にこじり角を

5

°以下で御願い致します。

 

仮差しの状態から片側のみを挿入した場合、下図の様にこじり

MAX.

値が

5

°となります。

 

5

°以下であればコネクタの変形は発生致しません。

 

To use this connector safely, please keep mating slant 5° or less as shown in the figure below. 

When you insert only one side in the temporary insert condition, maximum slant degree will become 5°. 

By keeping the slant 5° or less, deformation of the connector doesn't occur. 

为了能够使安全的使用此连接器,请注意在插入时,插入角度应该不大于

5

°。

如下图所示。

 

如果在预备插入时,只是按压一侧的状况下,那么斜着插入的角度也不应该大于

5

°。

如下图所示。

 

5

°

以下进行插入时,那么连接器不会发生变形的不良

 

 

5

°こじり状態

  / 5

°

slanted condition. / 

斜插角度

5

°

 

 
 

垂直方向

Vertical Direction. / 

垂直方向

 

コネクタ挿入開始時の許容角度は下図の通りです。

 

The acceptable angle to start connector mating is below. 

最初的连接器插入的允许角度如下图所示

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

挿入開始時の許容角度

8

°

   

The acceptable angle to start connector insertion is 8

°

最初的连接器插入的允许角度

8

°

以下

 

5

°

 

挿入開始時の許容角度

5

°

 

The acceptable angle to start connector insertion is 5

°

最初的连接器插入的允许角度

5

°

以下

 

Summary of Contents for CABLINE-VS

Page 1: ...T Receptacle 20455 E Instruction Manual 5 S19019 January 8 2019 Y Miyazaki T Masunaga H Ikari 4 S18402 July 2 2018 A Koyanagi T Masunaga H Ikari 3 S17909 December 12 2017 Y Miyazaki T Masunaga H Ikar...

Page 2: ...nnector Product Name CABLINE VS PLUG Part No 20453 T 1 With PULL BAR 2 Without PULL BAR 3 With INSULATION PULL BAR The PCB side connector Product Name CABLINE VS RECEPTACLE Part No 20455 E part shows...

Page 3: ...K of the cable connector is upper side I PEX 1 Fig 1 2 How to mate 2 As shown in Fig 2 push both ends of cable side connector horizontally until the lock is locked 2 Plug 2 Fig 2 Push both ends of con...

Page 4: ...of cable side connector horizontally Then confirm whether there is space between mating confirmation surfaces 3 3 Fig 3 PULL BAR SHELL After mated push PULL BAR to the PCB side and lock it to SHELL o...

Page 5: ...connector above especially edge of pull bar when you insert Plug into Receptacle there is a possibility to damage PCB like picture below This downward force on edge of pull bar will be cause of short...

Page 6: ...ULL BAR When mating in case you mate the connector pushing PULL BAR as shown in Fig 7 1 2 there are possibilities to cause PULL BAR deformation or the rotation axis dropping out from the connector Ple...

Page 7: ...ract the pull tape forcedly toward mating direction It may deform the pull bar or rotation axis may come off from the connector 7 3 7 3 Fig 7 3 7 4 PULL BAR PULL BAR Do not pull the pull bar toward ar...

Page 8: ...hen you insert only one side in the temporary insert condition maximum slant degree will become 5 By keeping the slant 5 or less deformation of the connector doesn t occur 5 5 5 5 5 slanted condition...

Page 9: ...ntial C RECE SHELL RECEPTACLE SHELL has an insertion guide as shown in the figure below Please insert connector along this guide As long as inserting along the guide deformation of the connector doesn...

Page 10: ...tion NG Slanted un mating NG condition OK NG 8 Fig 8 PULL TAPE PULL BAR For the connector with PULL BAR with PULL TAPE PULL TAPE PULL BAR PULL TAPE First pull PULL TAPE to the direction and release th...

Page 11: ...then turn PULL BAR to direction Un mating method is same as described in Fig 8 Caution Except for part if you pull up the PULL BAR towards direction PULL BAR would have deformation or the connector wo...

Page 12: ...ing by pulling the horizontal part in parallel to PCB Caution Except for part if you pull up the PULL BAR towards direction PULL BAR would have deformation or the connector would have damage Also if y...

Page 13: ...connector doesn t occur 5 5 5 5 slanted condition 5 Cautions In case you un mate connector by pulling cable there is possibility to break the cable Please avoid such an un mating method In addition su...

Page 14: ...edge of pull bar will be cause of short and circuit and disconnection of PCB Layout Therefore please do not apply any load from above Plug PCB PCB CAUTION IN CABLE CONNECTOR HANDLING PULL BAR In case...

Page 15: ...to the cable attachment part of a plug connector Cable Cable Cable 13 Fig 13 14 Continuous force of the direction shown in black arrow in Fig 14 can damage connectors or cause the coming off from rece...

Page 16: ...n the receptacle is inserted into the damaged or distorted plug housing and it may cause short circuit Housing PLUG Receptacle Receptacle PLUG PLUG Part No 20490 0 T Plug for electrical inspection Par...

Reviews: