background image

 

CABLINE

®

-VS Instruction Manual 

Document No. 

HIM-08004

 

 

 
 

 

13

  / 

16

 

Confidential C                                                                   

 

本コネクタを安全に使用して頂く為に下図の様にこじり角を

5

°以下で御願い致します。

 

5

°以下であればコネクタの変形は発生致しません。

 

To use this connector safely, please keep insert slant 5° or less as shown in the figure below. 

By keeping the slant 5° or less, deformation of the connector doesn't occur.           

为了能够使安全的使用此连接器,请注意在拔出时,角度应该不大于

5

°

,如下图所示。

 

5

°

以下进行拔去作业,不会导致连接器变形等不良现象。

 

             

5

°こじり状態

  / 5

°

slanted condition / 5

°

斜着拔出状态

 

 

注意事項

  / Cautions. / 

注意事项

 

※ケ-ブル断線の恐れが御座いますのでケーブルを手に持ってのコネクタ挿抜は御控え下さい。

 

この様な挿抜を行いますと、ケ-ブルが局部的に大きな力が生じ、ケ-ブル芯線が

 

切れる恐れが有ります。特に数本での斜め引張りの場合、十分御注意下さい。

 

In case you un-mate connector by pulling cable, there is possibility to break the cable. Please avoid such an un-mating method. In 

addition, such an un-mating can cause locally-force to cable and the inner conductor can be damaged. Especially, slanted un-mating by 

holding some cables is more dangerous. Please be careful. 

 

因为会导致

Cable

被拉断的危险,所以禁止用手直接拿住

Cable

将连接器拔出。

 

如果直接拿住

Cable

进行拔出作业,有较大的力施加在

Cable

上,可能会导致

Cable

的芯线断裂。

 

特别要禁止只是拿住少数几根

Cable

斜着将连接器拉出。请特别注意不要发生此类情况。

 

         

 

     

             

NG                                                                      NG   

5

°

 

Summary of Contents for CABLINE-VS

Page 1: ...T Receptacle 20455 E Instruction Manual 5 S19019 January 8 2019 Y Miyazaki T Masunaga H Ikari 4 S18402 July 2 2018 A Koyanagi T Masunaga H Ikari 3 S17909 December 12 2017 Y Miyazaki T Masunaga H Ikar...

Page 2: ...nnector Product Name CABLINE VS PLUG Part No 20453 T 1 With PULL BAR 2 Without PULL BAR 3 With INSULATION PULL BAR The PCB side connector Product Name CABLINE VS RECEPTACLE Part No 20455 E part shows...

Page 3: ...K of the cable connector is upper side I PEX 1 Fig 1 2 How to mate 2 As shown in Fig 2 push both ends of cable side connector horizontally until the lock is locked 2 Plug 2 Fig 2 Push both ends of con...

Page 4: ...of cable side connector horizontally Then confirm whether there is space between mating confirmation surfaces 3 3 Fig 3 PULL BAR SHELL After mated push PULL BAR to the PCB side and lock it to SHELL o...

Page 5: ...connector above especially edge of pull bar when you insert Plug into Receptacle there is a possibility to damage PCB like picture below This downward force on edge of pull bar will be cause of short...

Page 6: ...ULL BAR When mating in case you mate the connector pushing PULL BAR as shown in Fig 7 1 2 there are possibilities to cause PULL BAR deformation or the rotation axis dropping out from the connector Ple...

Page 7: ...ract the pull tape forcedly toward mating direction It may deform the pull bar or rotation axis may come off from the connector 7 3 7 3 Fig 7 3 7 4 PULL BAR PULL BAR Do not pull the pull bar toward ar...

Page 8: ...hen you insert only one side in the temporary insert condition maximum slant degree will become 5 By keeping the slant 5 or less deformation of the connector doesn t occur 5 5 5 5 5 slanted condition...

Page 9: ...ntial C RECE SHELL RECEPTACLE SHELL has an insertion guide as shown in the figure below Please insert connector along this guide As long as inserting along the guide deformation of the connector doesn...

Page 10: ...tion NG Slanted un mating NG condition OK NG 8 Fig 8 PULL TAPE PULL BAR For the connector with PULL BAR with PULL TAPE PULL TAPE PULL BAR PULL TAPE First pull PULL TAPE to the direction and release th...

Page 11: ...then turn PULL BAR to direction Un mating method is same as described in Fig 8 Caution Except for part if you pull up the PULL BAR towards direction PULL BAR would have deformation or the connector wo...

Page 12: ...ing by pulling the horizontal part in parallel to PCB Caution Except for part if you pull up the PULL BAR towards direction PULL BAR would have deformation or the connector would have damage Also if y...

Page 13: ...connector doesn t occur 5 5 5 5 slanted condition 5 Cautions In case you un mate connector by pulling cable there is possibility to break the cable Please avoid such an un mating method In addition su...

Page 14: ...edge of pull bar will be cause of short and circuit and disconnection of PCB Layout Therefore please do not apply any load from above Plug PCB PCB CAUTION IN CABLE CONNECTOR HANDLING PULL BAR In case...

Page 15: ...to the cable attachment part of a plug connector Cable Cable Cable 13 Fig 13 14 Continuous force of the direction shown in black arrow in Fig 14 can damage connectors or cause the coming off from rece...

Page 16: ...n the receptacle is inserted into the damaged or distorted plug housing and it may cause short circuit Housing PLUG Receptacle Receptacle PLUG PLUG Part No 20490 0 T Plug for electrical inspection Par...