2. FPC 挿入方法/FPC Insertion Method/FPC 插入方式 

      FPC をコネクタに対して真っ直ぐに挿入して下さい。 
      FPC がしっかり奥まで挿入出来ているか、確認して下さい。 
      Please insert FPC straight in the connector. 
      Please confirm FPC is inserted into the end of mating part fully. 

   

将柔性

线

路板直接插入

接器 

     

FPC 已完全插入配合部分的末端 

 

 

図 3. FPC 挿入方法  (OK) / Fig.3 FPC insertion (OK) / 

3.FPC

插入方式(

OK

 

 
 

≪注意/Caution≫ 

  ・図 4 の様に FPC が斜め挿入になると、導通不良や短絡及び LOCK 不良の原因になります。 

  If it become the oblique insertion of FPC as shown in Fig. 4, electrical connection NG, short circuit and   

Lock NG will be caused. 
如果 FPC 斜插入,

则有可能导致电

接不良、短路和会

不良

。 

 

 

図 4. FPC 挿入方法  (NG) / Fig.4 FPC insertion (NG)/

4.FPC 插入方式 

 
 

OK 

NG 

Summary of Contents for 20588-004E-01

Page 1: ...8 MINIFLEX 4 ST 0 4mm pitch FPC Conn Part No 20588 0 E 01 Instruction Manual 2 S20049 January 22 2020 M Muro H Ikari 1 S19616 October 1 2019 R Morita T Masunaga H Ikari 0 S14494 December 1 2014 H Ika...

Page 2: ...le our FPC connector MINIFLEX4 ST properly and safely FPC MINIFLEX4 ST connector Product Name MINIFLEX4 ST Part No 20588 0 E 01 part shows the number of the connector position Pin Names of each part o...

Page 3: ...ut FPC FPC is not inserted there is no remarkable affect to the contact pressure and the reliability will not be damaged However there is the possibility that the insertion force rises in inserting FP...

Page 4: ...PC straight in the connector Please confirm FPC is inserted into the end of mating part fully FPC 3 FPC OK Fig 3 FPC insertion OK 3 FPC OK Caution 4 FPC LOCK If it become the oblique insertion of FPC...

Page 5: ...ential C FPC HOUSING FPC The check of FPC insertion becomes easy by preparing the cutout in FPC and preparing the HOUSING step FPC FPC 5 FPC OK Fig 5 FPC insertion OK 6 FPC OK NG Short insertion NG Ob...

Page 6: ...gives damage to FPC and contact is damaged It becomes the electrical connection NG FPC FPC 7 FPC NG Fig 7 FPC insertion NG FPC NG 3 To close actuator FPC Push the center of actuator to the arrowed dir...

Page 7: ...aution Please do not press an actuator from a top Actuator is damaged and a function is not satisfied 9 NG Fig 9 To close actuator NG 9 OK Please do not operate side of an actuator Actuator is damaged...

Page 8: ...ontacts are damaged pin 11 NG Fig 11 To close actuator NG 11 NG FPC Please do not press housing on top and actuator after a close actuator Connector and FPC are damaged It becomes the electrical conne...

Page 9: ...4 To release actuator Raise the center of actuator upwards lightly 13 OK Fig 13 To release actuator OK 13 JIG When release actuator is difficult raise the center of actuator upwards lightly using the...

Page 10: ...o the direction of FPC mating side Actuator and contacts are damaged 15 NG Fig 15 To release actuator NG 15 NG Please do not operate side of an actuator Actuator is damaged 16 NG Fig 16 To release act...

Page 11: ...on FPC 17 FPC OK Fig 17 To withdraw FPC OK 17 FPC OK Caution FPC FPC Please refrain from slanted withdrawing FPC It may cause deformation of Connector and FPC FPC FPC 18 FPC NG Fig 18 To withdraw FPC...

Page 12: ...tial C 20 a b Fig 20 In case withdrawing FPC with a actuator close condition or b actuator release condition 20 a FPC b FPC 21 FPC FPC FPC If FPC receives damage like Fig 21 FPC retention force will b...

Page 13: ...stiffener FPC FPC 21 FPC OK Fig 21 Flexion of FPC OK 21 FPC OK Caution FPC FPC FPC Please avoid applying excessive stress to the FPC connector exit part FPC stiffener with FPC inserted Housing and con...

Page 14: ...after mounting SMT PCB 90mm PCB 0 5mm JEITA ED 4702C Be careful that warp of 90mm width PCB is 0 5mm or less If excessive warp is applied Connector is damaged Reference standard JEITA ED 4702C 90mm P...