ida 812-1x MIO Operator’s Guide
Installation
-16-
WARNING!
The twinax cable must
never
be connected directly to
the twinax socket of the printer. It must
always
be
connected to the T-cable.
3.4. Printer Emulations
On the
ida 812-1x MIO
it is possible to emulate the following IBM
printers once the interface card has been installed:
•
3812-1/5219
•
5224-2
•
5225-2
•
5256 -120
•
4234-2
Factory default is 3812-1/5219
emulation. You change this emulation
in the following way (provided that the printer has been configured
as described in
Section 3.2, Printer Configuration Procedure
)
1. Turn printer power
OFF
and disconnect the twinax cable.
2. Press and hold the
[TEST]
key on the interface and turn printer
power
ON
.
3. When the printer is ready the following will be printed:
"Current emulation is xxxx"
4. Turn the
Device Address
switch on the rear panel to the required
value according to the following table:
VALUE
EMULATION
0
3812-1/5219
1
5224-2
2
5225-2
3
5256-120
4
4234-2
5. Press the
[TEST]
key again and the selected emulation will be
printed.