background image

Hyundai

07

MMA-

100/120/140/160/180/200

 

Note :

  Please install the machine strictly according to the following steps. Turn off the power supply 

switch before any electric connection operation. The protection class of this machine is IP21S, so 
avoid using it in rain.

Installation method

1)  A primary power supply cable is available for this welding machine. Connect the power supply cable to the 

rated input power.

2) The primary cable should be tightly connected to the correct socket to avoid oxidization.
3) Check whether the voltage value varies in acceptable range with a multi-meter.
4)   Insert the cable plug with electrode holder into the “+” socket on the front panel of the welding machine, 

and tighten it clockwise.

5)  Insert the cable plug with work clamp into the “-” socket on the front panel of the welding machine, and 

tighten it clockwise.

6)  Ground connection is needed for safety purpose.

The connection as mentioned above in 6.1(4) and 6.1(5) is DCEP connection. Operator can choose DCEN 
connection according to work piece and electrode application requirement. Generally, DCEP connection is 
recommended for basic electrode, while no special requirement for acid electrode.

Operation method

1)  After being installed according to the above method, and the power switch being switched on, the    

machine is started with the power LED on and the fan working.

2)  Pay attention to the polarity when connecting. Phenomena such as unstable arc, spatter, and electrode 

sticking could happen if improper mode is selected. Exchange the polarity if necessary.

3)  Select cable with larger cross-section to reduce the voltage drop if the secondary cables (welding cable 

and earth cable) are long.

4)  Preset the welding current according to the type and size of the electrode, clip the electrode and then 

welding can be carried out by short circuit arc starting. For welding parameters, please refer to the table in 
next page.

6. Installation Debugging and Operation

Summary of Contents for MMA series

Page 1: ...DC INVERTER MMA WELDER MMA 100 120 140 160 180 200 User Manual For Your Safety Read and understand this manual before use Keep this manual for future reference EN...

Page 2: ...r therefore some parts of this welder may be changed in order to achieve the better quality but the main functions and operations will not be alternated and changed Your understanding would be greatly...

Page 3: ...200 Safety General Description Main Parameters Electric Block Diagram Operation Control and Description Installation Debugging and Operation Caution Maintenance Troubleshooting Exploded Drawing 2 3 4...

Page 4: ...earing wet gloves clothes Make sure that you are insulated from the ground and work piece Make sure that your working position is safe Smoke gas may be harmful to health Keep the head away from smoke...

Page 5: ...eek professional help if you still cannot fully understand after reading the manual or still cannot solve the problem according to the manual Advanced DC inverter technology High inverter frequency gr...

Page 6: ...VA 3 8 4 7 5 6 6 6 7 7 9 Rated Input Current A 17 21 26 30 35 41 Rated Output Current Voltage 100A 24 0V 120A 24 8V 140A 25 6V 160A 26 4V 180A 27 2V 200A 28 0V Output Current A 10 100 10 120 10 140 10...

Page 7: ...Hyundai 05 MMA 100 120 140 160 180 200 4 Electric Block Diagram...

Page 8: ...model optional 4 Power LED To indicate the power Power LED on indicates that the power switch of the machine is on 5 Overheating LED To indicate overheating Overheating LED on indicates that the temp...

Page 9: ...d for safety purpose The connection as mentioned above in 6 1 4 and 6 1 5 is DCEP connection Operator can choose DCEN connection according to work piece and electrode application requirement Generally...

Page 10: ...e machine so please note 1 Ventilation High current passes when welding is carried out thus natural ventilation can not satisfy the machine s cooling requirement Maintain good ventilation through the...

Page 11: ...including that between the connections and that between the connection and the enclosure Only when there are no abnormal phenomena anymore then the machine can be used 5 Check periodically whether th...

Page 12: ...ne If any reconnect Turn on the machine the power LED is on the fan works but no welding output 1 Check if any loose contact exists inside the machine 2 Open circuit or loose contact occurs at the joi...

Page 13: ...3 Output current adjustment knob 4 Power LED Overheating LED Indicator 5 Quick Connectors 6 Front Panel 7 PCB 8 Back Panel 9 Cable Fastener 10 Power Switch 11 Plastic Cover Optional only for Plastic...

Page 14: ...R MMA WELDER MODEL MMA 100 120 140 160 180 200 Satisfies the requirements of the Council Directives EC Low voltage directive 2014 35 EU EC Directive of Electromagnetic Compatibility 2014 30 EU RoHS Di...

Page 15: ......

Page 16: ...HYUNDAI Corporation 25 Yulgok ro 2 gil Jongno gu Seoul 03143 Korea Post Code 03143 82 2 390 1114 www hyundaicorp com Copyright 2016 HYUNDAI Corporation All rights reserved Made in P R C...

Reviews: