Emergency procedures
2. Before disconnecting the 12V battery, move the
smart key at least 2 meters away from the vehicle
to prevent accidental restart.
3. Disconnect the negative (-) 12V battery cable
located in the PE room, to further prevent the risk
of accidental restart.
10
Smart Key
If necessary, lower the windows, unlock the
doors and open the trunk as required, before
disconnecting the 12V battery. Once the 12V
battery is disconnected, power controls will not
operate.
NOTICE
4. Use the following procedure to isolate the high voltage of the battery.
4-1 . Remove the High voltage cut-off Switch located in the low voltage junction block.
a) Remove the Junction block upper cover
ⓐ
in the PE room
a
Summary of Contents for IONIQ 5
Page 1: ...Emergency Response Guide IONIQ 5...
Page 22: ......