4.4.7.
IMPORTANT: To prevent gum deposits from forming in fuel system parts such
as the carburetor, fuel hose or tank during storage. Alcohol-blended fuels
(called gasohol), ethanol or methanol can attract moisture, which leads to
separation and formation of acids during storage. Acidic gas can damage the
fuel system
. Fuel
should be emptied before storage for 30 days or longer. See
the “Storage” section. NEVER use engine or carburetor cleaner products in the
fuel tank as permanent damage may occur.
4.5.
Grounding (Earthing) the generator.
4.5.1.
The Requirement for Electrical Installations BS 7971:2008 requires that the
frame and external electrically conductive part of this generator be properly
connected to an approved earth ground.
4.5.2.
Proper grounding of the generator will help prevent electric shock in the
event of ground fault condition in the generator or in connected electrical
devices.
4.5.3.
Proper grounding also helps dissipate static electricity, which often builds up in
ungrounded devices.
4.6. Floating earth portable generator use.
4.6.1. This range of generators adopt a floating earth configuration which means that
the Neutral of the alternator is not connected to the Earth of the machine.
4.6.2. It is therefore IMPORTANT that you ONLY use the generator to supply
equipment in the following combinations.
4.6.2.1. One or more of CLASS II equipment
4.6.2.2. Only ONE item of Class I equipment
4.6.2.3. One or more of CLASS II equipment and only ONE item of Class I
equipment.
4.6.3. CLASS I equipment has a GREEN/YELLOW earth wire connected inside the plug.
4.6.4. CLASS II equipment DOES NOT have GREEN/YELLOW earth wire connected
inside the plug.
4.6.5. CLASS II equipment will have the following symbol embossed or
printed on the casing.
Page 12
Ver 2 - December 2016
Summary of Contents for HY10000LEK-2
Page 2: ...Page 2 Ver 2 December 2016 ...
Page 26: ...Page 26 Ver 2 December 2016 ...
Page 27: ...Page 27 Ver 2 December 2016 ...