![Hyundai HSH-P182NDC Service Manual Download Page 20](http://html.mh-extra.com/html/hyundai/hsh-p182ndc/hsh-p182ndc_service-manual_2195070020.webp)
6
6
.
.
C
C
O
O
N
N
T
T
R
R
O
O
L
L
M
M
O
O
D
D
E
E
18
b. When the room temperature exceeds 23℃, but below 26℃, it will be ran in
the Dry mode(It will turn in Automatic setting After 3 min LOW air volume running.).
c. When the room temperature exceeds 21℃, but below 23℃, it will be operated
in the Fan only, the air volume is set by LOW and the fan speed can be adjusted
d. When the room temperature is not more than 21℃, it will be operated in Heat
mode, and the temperature is set to 22℃.
(2) Cool only appliance
a. When the room temperature exceeds 26℃, it will be ran in Cool mode, and the
temperature is set to 26℃.
b. When the room temperature exceeds 23℃, but not more than 26℃, it will be
operated in the Dry mode.
c. When the room temperature is not more than 23℃, it will be operated in the
Fan only, the air volume is set to LOW and the fan speed can be adjusted
After the appliance start the smart operation, the setting temperature can be
adjusted 2℃
(the min accuracy is
1℃) up and down base on the automatic temperature
setting, also the presetting temperature of PCB circuit.
In case of the specific operation selected, it could be re-select the other modes
after the compressor ceased for 5 min or the setting temperature changed.
4.6 Super
Whether the appliance is in operation or stand-by, when the “Super”signal is
received from the remote control, it will operated at the Cool mode and set the
temperature at 18℃ and fan speed setting is High.
5. Supplementary
5.1 Time mode operation
Non-real time of Timer with remote controls can be suit for the appliance.
5.1.1 Non-real time of Timer setting
(1)The max Timer ranges is 24 hours.
(
2
)
Timer
ON/OFF
(
3
)
Timer
ON/OFF can be set available in turn.
(4)The
Timer
accurate more than 97%
(5)The
Timer
can be adjusted by 0.5 hour increase.
(6)The OFF-Timer can be set when the appliance is in operation, the ON-timer
can be set when the appliance is in suspension, and the Timer setting is display.
5.2 Sleep mode operation
(1)The Sleep mode can only be set during Cool, Heat and Dry mode.
(2)When the appliance run in the Sleep mode, it will stop after 8 hours operation,
then it will cancel the Sleep setting. When the appliance operate under the OFF-Timer
setting condition, if the OFF-Timer setting less than 8 hours, it will keep the Sleep
mode till the OFF-Timer setting; if the OFF-Timer setting more than 8 hours, it will
cancel the OFF-Timer setting after the Sleep mode OFF.
(3)When the Sleep mode is select with Cooling mode, if the room temperature
Summary of Contents for HSH-P182NDC